Troubleshooting - Electronic Ignition
Problem (Ignition) | Possible Cause | Check Procedure | Prevention/Solution |
|
|
|
|
SECTION I | • Battery not installed | • Check battery orientation. | • Install battery (make sure that “+” and |
No sparks appear at | |||
any electrodes when | properly. |
| connectors are oriented correctly, with “+” end up |
Electronic Ignition Button |
|
| and |
is pressed; no noise can | • Dead battery. | • Has battery been used | • Replace battery with new alkaline battery. |
be heard from spark | |||
module. |
| previously? |
|
| • Button assembly not | • Check to insure threads are | • Unscrew button cap assembly and reinstall, making |
| installed properly. | properly engaged. Button | sure threads are aligned and engaged fully. |
|
| should travel up and down |
|
|
| without binding. |
|
| • Faulty spark module. | • If no sparks are generated | • Replace spark module assembly. |
|
| with new battery and good |
|
|
| wire connections, module is |
|
|
| faulty. |
|
|
|
|
|
SECTION II | • Output lead | • Are output connections on | • Remove and reconnect all output connections at |
No sparks appear at | |||
any electrodes when | connections not | and tight? | module and electrodes. |
Electronic Ignition Button | connected. |
|
|
is pressed; noise can |
|
|
|
be heard from spark |
|
|
|
module. |
|
|
|
|
|
|
|
SECTION III | • Output lead | • Are output connections on | • Remove and reconnect all output connections at |
Sparks are present | connections not | and tight? | module and electrodes. |
but not at all | connected. |
|
|
electrodes and/or not | • Arcing to grill away | • If possible, observe grill in | • If sparks are observed other than from burner(s), |
at full strength | |||
| from burner(s). | dark location. Operate | wire insulation may be damaged. Replace wires. |
|
| ignition system and look for |
|
|
| arcing between output wires |
|
|
| and grill frame. |
|
| • Weak battery. | • All sparks present but weak | • Replace battery with a new alkaline battery. |
|
| or at slow rate. |
|
| • Electrodes are wet. | • Has moisture accumulated | • Use paper towel to remove moisture. |
|
| on electrode and/or in burner |
|
|
| ports? |
|
| • Electrodes cracked or | • Inspect electrodes for | • Replace cracked or broken electrodes. |
| broken “sparks at | cracks. |
|
| crack”. |
|
|
|
|
|
|
30