Weber 700 LX owner manual Set LP fuel scale, Fill LP tank

Page 15

Step 12

Set LP fuel scale

You will need: LP tank (empty).

Note - For accuracy, the fuel scale must be set with an empty tank.

We utilize various LP tank manufacturers. Some of the tanks we receive have differing top collar assemblies. (The top collar is the metal protective ring around the valve.) One series of tanks mounts with the valve facing front. The other tanks mount with the valve facing away from the fuel scale. These types of tanks are illustrated in Figure 14.

Loosen the tank lock wing nut. Tighten so the lock is held up out of the way. Figure 14 (a). Lift and hook the tank onto the fuel scale. With an empty LP tank, adjust the fuel scale setting to E with scale setting (top) wing nut. Figure 14 (b).

mCAUTION: Do not remove adjustment wing nut from tank scale.

After adjusting tank scale, push tank down a couple of times to check that the tank scale is set on “E”.

Step 13

Fill LP tank

Note - The LP tank manufacturer is responsible for the materials, workmanship and performance of the tank. If the tank has a defect, malfunctions, or you have a question regarding the tank, call the tank manufacturer's customer service center. The phone number is on the warning decal which is permanently attached to the tank. If the tank manufacturer has not resolved the issue to your satisfaction, then call Weber-Stephen Products Co., Customer Service Center.

To fill, take the LP tank and filler adapter to an RV center or look up gas-propane in the phone book for other sources of LP gas.

mWARNING: We recommend that your LP tank be filled at an authorized LP gas dealer by a qualified attendant, who fills the tank by weight.

IMPROPER FILLING IS DANGEROUS.

Tell your LP dealer that this is a new LP tank. The air must be removed from a new LP tank before the initial filling. Your LP tank dealer is equipped to do this.

mWARNING: If you exchange your LP tank, make sure you get a similar tank in return. Your LP tank is equipped with a quick-disconnect valve and an OPD (Overfilling Prevention Device). Other LP tanks are not compatible with your barbecue connection.

Tank lock

Scale setting

The LP tank must be installed, transported and stored in an upright position. LP tank should not be dropped or handled roughly.

wing nut

wing nut

Never store or transport the LP tank where temperatures

(a)(b)

E E

F F

Figure 14

can reach 125° Fahrenheit (too hot to hold by hand – for example: do not leave the LP tank in a car on a hot day).

For full instructions on safe handling of LP tanks, see Section "Safe handling tips for LP gas".

15

Image 15
Contents Spirit 700 LX Series LP GAS Units only MDANGER MWARNINGSWarranty Patents and Trademarks Contents Operating area For Installation in CanadaGeneral Instructions StorageAssembly Check package contentsStep REB Check contents of hardware packs Assemble top frame Assemble wheel frameContinue frame assembly Install tubing plugsAdd front panel Add cooking box Install tank panel assembly and frame connector Install manifold bracketInstall igniter Add fuel scale assemblyMCAUTION Do not remove adjustment wing nut from tank scale Set LP fuel scaleFill LP tank Connect LP tank Check that all burner valves are offCheck for gas leaks MWARNING Do not ignite burners when leak checkingCooking box with finger grip toward you. Figure Install Flavorizer Bars and Cooking GratesInstall the bottom tray Slide the bottom tray onto the mounting rails underAdd tool holders, control panel and burner control knobs Install LidMWARNING The load limit for the swing table is 30 pounds Install swing tableComplete accessory installation To Extinguish LightingManual Lighting Storage and/or Nonuse Periodic CleaningCooking Storage and/or NonuseConnecting the filled LP tank Refilling the LP tankRemoval of the LP tank Male fitting Regulator Liquid Propane LP Tanks Safe handling tips for LP GasAnnual Maintenance Inspection and Cleaning of the Weber Spider Stopper GuardsMWARNING Do not ignite burners while leak checking Weber Spider Stopper Guards General MaintenanceMain Burner Cleaning Procedure MCAUTION Do not enlarge the burner ports when cleaningTo reinstall the burners, reverse steps c through g Crossover Ignition System Operations MCAUTION Do not line the bottom tray with aluminum foil Burner does not light, or flame is low in High positionPage 15-16 Parts List Final Word Thanks
Related manuals