Weber 700 LX Annual Maintenance, Inspection and Cleaning of the Weber Spider Stopper Guards

Page 28

Annual Maintenance

After a period of nonuse we recommend that you perform the following maintenance procedures for your safety.

mWARNING: Check hose before each use of barbecue for nicks, cracking, abrasions or cuts. If the hose is found to be damaged in any way, do not use the barbecue. Replace using only Weber authorized replacement manifold assembly. Order from Weber- Stephen Products Co., Customer Service Center or authorized dealer.

Inspect the burners for correct flame pattern. Clean if necessary, following the procedures outlined in the "General Maintenance" section of this manual.

Check all gas fittings for leaks.

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. This will result in a fire or explosion which can cause serious bodily injury or death, and damage to property.

mWARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

You will need: a soap and water solution and a rag or brush to apply it.

To perform leak checks: Make sure all burners are in the OFF position. Turn on gas supply.

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows there is a leak.

Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

mWARNING: Do not ignite burners while leak checking.

Check:

a)Hose to manifold connection. Figure 8 (a).

b)Regulator to tank connection. Figure 8 (b).

mWARNING: If there is a leak at connection (a) retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact

Weber-Stephen Customer Service.

Check:

c)Valves to manifold connections. Figure 8 (c).

d)The hose to regulator connection. Figure 8 (d).

mWARNING: If there is a leak at connections

(b), (c) or (d), turn OFF the gas. DO NOT OPERATE

THE BARBECUE. Contact Weber-Stephen Customer Service.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

(a)

(b)

(c)

(d)

Figure 8

Inspection and Cleaning of the Weber Spider Stopper Guards

To inspect the Spider Stopper Guards, remove the control panel and look to see if they have dust or dirt on their outside surfaces. If they are dirty, brush off the outside surface of the Spider Stopper Guards with a soft bristle brush (an old toothbrush for example). Check that there are no gaps in the Spider Stopper Guards’ seams or in the fit around the burners or valves. (See Section "General Maintenance".)

28

Image 28
Contents Spirit 700 LX Series MDANGER MWARNINGS LP GAS Units onlyWarranty Patents and Trademarks Contents For Installation in Canada General InstructionsStorage Operating areaCheck package contents AssemblyStep REB Check contents of hardware packs Assemble wheel frame Assemble top frameInstall tubing plugs Continue frame assemblyAdd front panel Add cooking box Install manifold bracket Install tank panel assembly and frame connectorAdd fuel scale assembly Install igniterSet LP fuel scale MCAUTION Do not remove adjustment wing nut from tank scaleFill LP tank Check that all burner valves are off Connect LP tankMWARNING Do not ignite burners when leak checking Check for gas leaksInstall Flavorizer Bars and Cooking Grates Install the bottom traySlide the bottom tray onto the mounting rails under Cooking box with finger grip toward you. FigureInstall Lid Add tool holders, control panel and burner control knobsInstall swing table MWARNING The load limit for the swing table is 30 poundsComplete accessory installation Lighting To ExtinguishManual Lighting Periodic Cleaning CookingStorage and/or Nonuse Storage and/or Nonuse Refilling the LP tank Connecting the filled LP tank Removal of the LP tank Male fitting Regulator Safe handling tips for LP Gas Liquid Propane LP TanksInspection and Cleaning of the Weber Spider Stopper Guards Annual MaintenanceMWARNING Do not ignite burners while leak checking General Maintenance Main Burner Cleaning ProcedureMCAUTION Do not enlarge the burner ports when cleaning Weber Spider Stopper GuardsTo reinstall the burners, reverse steps c through g Crossover Ignition System Operations Burner does not light, or flame is low in High position MCAUTION Do not line the bottom tray with aluminum foilPage 15-16 Parts List Final Word Thanks