Weber 700 LX General Maintenance, Weber Spider Stopper Guards, Main Burner Flame Pattern

Page 29

General Maintenance

Weber Spider Stopper Guards

Your Weber Gas Barbecue, as well as any outdoor gas appliance, is a target for spiders and other insects. They can nest in the venturi section of the burner tubes. This blocks the normal gas flow, and can cause the gas to flow back out of the air shutter. Figure 9. This could result in a fire in and around the air shutters, under the control panel, causing serious damage to your barbecue.

Venturi

Main Burner Flame Pattern

The Weber Gas Barbecue burners have been factory set for the correct air and gas mixture. The correct flame pattern is shown in Figure 11.

Tips occasionally yellowish

Burner inside cooking box

Light blue

Dark blue

Flames

Figure 11

Air shutter

Venturi fin

If the flames do not appear to be uniform the length of the burner tube, follow the burner cleaning procedures.

Figure 9

The Weber Spider Stopper Guard is factory installed. It fits tightly around the air shutter section of the burner tube and the valve, thereby preventing spiders and other insects access to the burner tubes through the air shutter openings. Figure 10.

Weber Spider

Stopper Guard

Figure 10

We recommend that you inspect the Weber Spider Stopper Guards at least once a year. (See Section “Annual Maintenance”.) Also inspect and clean the Spider Stopper Guards if any of the following symptoms should ever occur.

1.The smell of gas in conjunction with the burner flames appearing yellow and lazy.

2.Barbecue does not reach temperature.

3.Barbecue heats unevenly.

4.One or more of the burners do not ignite.

Main Burner Cleaning Procedure

Turn off the gas supply. Remove the manifold. (See Section “Replacing the main burners”.)

Look inside each burner with a flashlight. Figure 12.

Figure 12

Clean the inside of the burners with a wire (a straightened out coat hanger will work). Figure 13. Check and clean the air shutter opening at the ends of the burners. Check and clean the valve orifices at the base of the valves. Use a brass bristle brush to clean outside of burners. This is to make sure all the burner ports are fully open.

Figure 13

mCAUTION: Do not enlarge the burner ports when cleaning.

mDANGER

Failure to correct these symptoms may result in a fire which can cause serious bodily injury or death and cause damage to property.

Replacing Main Burners

a)Your Weber Gas Barbecue must be OFF and cool.

b)Turn gas OFF at source.

c)Remove control panel: take off the burner control knobs. Remove the screws holding the control panel in place. Lift off the control panel.

29

Image 29
Contents Spirit 700 LX Series LP GAS Units only MDANGER MWARNINGSWarranty Patents and Trademarks Contents General Instructions For Installation in CanadaStorage Operating areaStep AssemblyCheck package contents REB Check contents of hardware packs Assemble top frame Assemble wheel frameAdd front panel Continue frame assemblyInstall tubing plugs Add cooking box Install tank panel assembly and frame connector Install manifold bracketInstall igniter Add fuel scale assemblyFill LP tank MCAUTION Do not remove adjustment wing nut from tank scaleSet LP fuel scale Connect LP tank Check that all burner valves are offCheck for gas leaks MWARNING Do not ignite burners when leak checkingInstall the bottom tray Install Flavorizer Bars and Cooking GratesSlide the bottom tray onto the mounting rails under Cooking box with finger grip toward you. FigureAdd tool holders, control panel and burner control knobs Install LidMWARNING The load limit for the swing table is 30 pounds Install swing tableComplete accessory installation To Extinguish LightingManual Lighting Cooking Periodic CleaningStorage and/or Nonuse Storage and/or NonuseRemoval of the LP tank Connecting the filled LP tankRefilling the LP tank Male fitting Regulator Liquid Propane LP Tanks Safe handling tips for LP GasMWARNING Do not ignite burners while leak checking Annual MaintenanceInspection and Cleaning of the Weber Spider Stopper Guards Main Burner Cleaning Procedure General MaintenanceMCAUTION Do not enlarge the burner ports when cleaning Weber Spider Stopper GuardsTo reinstall the burners, reverse steps c through g Crossover Ignition System Operations MCAUTION Do not line the bottom tray with aluminum foil Burner does not light, or flame is low in High positionPage 15-16 Parts List Final Word Thanks