Weber Genesis Silver B Gas Grill, 55159 manual Install igniter, Purge air from gas lines

Page 21

Step 11

Install igniter

Note - The igniter wires are already attached to the Gas Catcher Ignition Chamber and the igniter. This was done to factory test the ignition system.

The igniter lock nut is on the igniter.

Insert the top of the igniter up through the large part of the keyhole in the frame brace. Figure 17 (b). Loosen the igniter lock nut and slide the igniter into the small part of the keyhole. Figure 17 (c). Tighten the igniter lock nut. Figure 17.

Note - If the igniter works loose, carefully tighten the igniter lock nut with an adjustable wrench or pliers.

(a)

Frame brace

(b)

 

Keyhole in

 

(c)

frame brace

Igniter lock nut

 

 

 

Frame brace

Small part of keyhole in frame brace

Figure 17

Step 12

Purge air from gas lines

You will need: one burner control knob.

DANGER

Be sure there are no sparks or open flames in the area while purging. This can cause fire, explosion or serious bodily injury.

It is necessary to bleed the air out of newly installed gas lines. Turn gas supply ON at the source. Put on the front burner control knob. Push the front burner control knob down and turn to HI. When you start

to smell gas, turn front burner control knob to OFF. Figure 18.

Figure 18

21

Image 21
Contents Owners Guide Page Customer Service Center Roselle Road, Suite Schaumburg, IL WarrantyContents Gas supply testing Operating area For Installation in CanadaGeneral Instructions StorageGenesis Silver-B Permamount NG Page Page Page Page General Specifications for Piping Typical natural gas supply installation to a wood deck Recommended concrete pad requirements Continue frame assembly StepAssemble the frame Add Wrap-around Frame Panel Measure and drill holes Method 1 Concrete Method 2 ConcreteMethod 3 Concrete Method 4 Wood deck Add cooking box Install manifold bracket Connect barbecue gas supply line to the natural gas supplyCheck all valves are off Purge air from gas lines Install igniterCheck for gas leaks BARBECUE. Contact Weber-Stephen Customer ServiceAdd base panel Install side panelsInstall the bottom tray Install Flavorizer Bars and Cooking GratesAdd tool holders, control panel and burner control knobs Install LidInstall the condiment basket Complete accessory installation Install the accessory rackTo Extinguish LightingManual Lighting Cooking Periodic CleaningAfter a Period of Nonuse Drippings and greaseInspection and cleaning of the Spider/Insect screens Annual MaintenanceMain Burner Cleaning Procedure General MaintenanceWeber Spider/Insect Screen Replacing Main BurnersPage Crossover Ignition System Operations Burner does not light, or flame is low in High position When burner is on HIGH. Flames do not runExperiencing flare-ups Burner flame pattern is erratic. Flame is low