Weber 55062 manual Manual Lighting

Page 18

Manual Lighting

DANGER

Failure to open lid while igniting the barbecue’s burners, or not waiting 5 min- utes to allow the gas to clear if the barbe- cue does not light, may result in an explo- sive flame-up which can cause serious bodily injury or death.

1)Open the lid.

2)Make sure all burner control knobs are turned OFF. (Push each burner control knob down and turn clockwise to ensure they are in the off posi- tion.)

3)Turn the gas supply valve on.

4)Strike a match and put the flame into the matchlight hole in the front of the cooking box.

1

2

7

3

4,6 5

*The grill illustrated may have slight differences than the model purchased.

WARNING: Do not lean over the open barbecue. Keep your face and body at least one foot away from the matchlight hole when lighting the barbe- cue.

5)Push Front burner control knob down and turn to START/HI.

6)Check that the burner is lit by looking through the matchlight hole on the front of the cooking box. You should see a flame.

WARNING: If the burner does not light, turn the Front burner control knob to OFF and wait 5 minutes to let the gas clear before you try again or try to light with a match.

7) After the FRONT burner is lit you can turn on the other burner or burners.

Note - Always light the FRONT burner first. The other burner or burners ignite from the FRONT burner.

To Extinguish

Push down and turn each burner control knob clockwise to the OFF position. Turn gas supply OFF at the source.

D-2

Image 18
Contents Genesis GOLD-C Liquid Propane GAS Units only Warranty Customer Service Center South Hicks Road Palatine, ILContents For Installation in Canada Operating Gas Supply TestingStorage Genesis Gold-C NG Manifold, Hose and regulator assembled Page Remove Packaging from Grill Remove Grill from Lower PackagingPage Assembly Instructions Install the slide out bottom trayInstall the bottom shelf Installing the Warm-Up BasketInstalling the warming rack Install the condiment basketInstall Left Work Surface Install Side Burner AssemblyCheck that all burner valves are off Install Gas Supply General Specifications for Piping Remove the control panel Gas Line PipingTest Connections Check for gas leaksReinstall control panel after checking for gas leaks Lighting To ExtinguishManual Lighting Lighting the Side Burner Lighting only the side burnerCleaning CookingStorage Annual Maintenance Inspection and Cleaning of the Weber Spider Stopper GuardsGeneral Maintenance Main Burner Cleaning ProcedureWeber Spider Stopper Guards Replacing Main Burners Crossover Ignition System Operations Orange flame, in conjunction with Flame is low when burner is onBurners burn with a yellow or Smell of gasFlame is very yellow Side Burner does not lightFlame is low in High position Conjunction with the smell of gas