CHECK FOR GAS LEAKS
Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows there is a leak.
Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.
WARNING: Do not ignite burners when leak checking.
a)
c)
Manifold
To regulator
Summit 475 | d) |
Figure 24 |
|
| Manifold |
b)
a)
c)
Manifold
To regulator
d)
Summit 675
Figure 24
Manifold
Check:
a)Left valves to manifold connection. Figure 24 (a).
b)Center valves to manifold connection. Figure 24 (b). (For Summit 675 only.)
c)Right valves to manifold connection. Figure 24 (c).
d)Gas line to manifold connection. Figure 24 (d)
e)Leak check all gas supply connections.
WARNING: If there is a leak at connection 24 (d), turn OFF the gas and retighten the fitting with a wrench and recheck for leaks with soap and water solution.
If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact your dealer.
WARNING: If there is a leak at connections
24 (a), 24 (b), or 24 (c) turn OFF the gas. Do not operate the barbecue. Contact your dealer.
When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.
13