USING THE 1-HOUR OFF TIMER

1. 1-Hour OFF Timer

This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed.

The indicator in the display indicates that this function is operating.

ADJUSTING THE AIRFLOW DIRECTION

The vertical airflow can be adjusted by moving the flap with the remote controller. Do not move the flap with your hands. Confirm that the remote controller has been turned on. Use the FLAP button to set either the sweep function or one of the six airflow direction settings.

A. Sweep function

The flap starts moving up and down to deliver air over the sweep range.

Setting procedure:

Regardless of whether the unit is operating or stopped, press the 1 HR. TIMER button.

appears in the display.

Cancellation procedure:

Press the ON/OFF operation button to turn the unit off, wait for the unit to stop operating, and then press the ON/OFF operation button again.

The 1-Hour Timer function is now cancelled and the unit operates normally.

B. Setting the airflow manually

Referring to the above illustration, use the FLAP button to set the airflow direction within the range used during the heating, cooling, or dehumidifying operation.

C. Auto flap function

SWEEP

COOL

DRYSWEEP FAN

HEAT

NOTE

If, while the 1-Hour Timer function is operating, the 1HR. TIMER button is pressed once to cancel the function and then again, the unit continues to operate for one hour from that point in time and then stops.

It is not possible to use the OFF Timer and 1-Hour OFF Timer together. Whichever function is set last takes precedence. If the 1 HR. TIMER button is pressed while the TIMER OFF function operates, the OFF Timer is cancelled and the unit will stop operating one hour later.

2.Operation together with the daily ON/OFF repeat timer

The 1-Hour OFF Timer setting is given priority over the DAILY ON/ OFF REPEAT setting.

TIPS FOR ENERGY SAVING

Avoid

Do not block neither the air intake nor the air outlet. It may cause less performance, and may leads to malfunctions.

Do not let direct sunlight into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer to cool the room.

Do

Always try to keep the air filter clean. (Refer to “CARE AND CLEANING”.) A clogged filter will impair the performance of the unit.

To prevent conditioned air from escaping, keep windows, doors and any other openings closed.

The flap is set to the recommended position.

NOTE

The flap automatically closes when the unit is off.

During the heating operation, the fan speed will be very low and the flap will be in the horizontal position (position ) until the air being blown out of the unit begins to warm. Once the air warms up, the flap position and fan speed change to the settings specified with the remote controller.

CAUTION

Use the FLAP button on the remote controller to adjust the position of the flap. If you move the flap by hand, the flap position according to the remote controller and the actual flap position may no longer match. If this should happen, shut off the unit, wait for the flap to close, and then turn on the unit again; the flap position will now be normal again.

Do not have the flap pointed down during cooling operation. Condensation may begin to form around the air vent and drip down.

13

Image 71
Contents 17,500BTU / h 11,900BTU / hSafety Precautions Prohibit Table of Contents CZ-RD515U Applicable MULTI-OUTDOOR Units Operating Range Temperature Indoor Air Intake Temp Outdoor Air Intake TempIndoor Unit CS-MKE9NB4U & CZ-18BT1U SpecificationsUnit Specifications 208V Indoor UnitIndoor Unit CS-MKE12NB4U & CZ-18BT1U CS-MKE12NB4U & CZ-18BT1U Indoor Unit CS-KE18NB4UW & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1U Indoor Unit Panel CZ-18BT1U Major Component SpecificationsIndoor Unit Indoor Unit Body CS-MKE9NB4UCB-CS-MKE12NB4U Indoor Unit Body CS-MKE12NB4UCB-CS-KE18NB4U Indoor Unit Body CS-KE18NB4UWCS-MKE12NB4U & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1U Other Component SpecificationsView Dimensional DataIndoor Unit CS-KE18NB4UW & CZ-18BT1U Indoor unit Refrigerant Flow DiagramElectrical Data Electric Wiring DiagramsRemove the air intake grill MaintenanceDisassembly Procedure Disconnect the connectors in the control boxRemove the ceiling panel Remove the power box and control box Remove the indoor air temperature sensorScrew Ground cable CN07 CN03 CN09 CN06 Remove the main body lower section Remove the heat exchanger sensor Remove the drain pump and float switchRemove the heat exchanger Remove the turbo fan and fan motorAuto cooling/heating operation FunctionsOperation Functions Emergency operationLamp colors Timer backupCold-air prevention during heating Protective FunctionsOverload prevention during heating Freeze preventionMethod of Self-Diagnostics Troubleshooting Before Calling for ServicePrecautions before Performing Inspection or Repair Indoor Unit Self-diagnostics LampsReplace the circuit board or the fuse Using the TEST/T-RUN terminalsChecking the Indoor and Outdoor Units Replace the controllerCondition E01 Serial Communication Error Identification ProcedureOff Blinking Illuminated Before the OperationFrom the previous page a Condition E12 Indoor Fan Motor Trouble Diagnosis of Fan MotorLocations most susceptible to noise Trouble Correction Noise Malfunction and Electromagnetic InterferenceNoise malfunction Electromagnetic interferencePage CS-MKE9NB4U & CZ-18BT1U CS-MKE12NB4U & CZ-18BT1U Appendix aCeiling Panel CZ-18BT1UModel No Indoor Units Product Information FeaturesContents Safety PrecautionsAvoid Installation LocationSafety Instructions Electrical RequirementsUnit Display and Operation Button Names of PartsSymbols Remote Controller DisplayRemote Controller Sensor HR. Timer button 1-HOUR OFF TimerTemperature setting buttons Temp Mode selector buttonSingle/Multiple switch Using the Remote ControllerStep Operation with the Remote ControllerAutomatic Operation Manual OperationHigh Power Mode Adjusting the Fan SpeedNight Setback Mode Special Remarks Setting the Timer1030 pm 710 am 1100 am Present time How to set the OFF timeHow to set the on time How to set daily ON/OFF repeat timerOperation together with the daily ON/OFF repeat timer Using the 1-HOUR OFF TimerAdjusting the Airflow Direction Hour OFF TimerCleaning the main unit and Remote Controller Care and CleaningWhen the air conditioner is not running Cleaning the flapsCare After a prolonged idle period How to remove the filterHow to remove the air intake grille Air filterOperating Range TroubleshootingWired Remote Controller Model No Ceiling Panel SpecificationsModel No Indoor Unit Model No Outdoor UnitCS-KE18NB4UW & CZ-18BT1U Appendix BCZ-18BT1U CS-KE12NB41CU-KE12NK1 CS-KE18NB4UW CU-KE18NKUFan Only Installation Location DRY orange, Cool green and FAN green Remote Controller Display Remote Controller FAN Using the Remote Controller Operation with the Remote Controller Fan Only Special Remarks How to set the OFF time Sweep Cool Drysweep FAN Heat Care and Cleaning Air filter Max Min For Single use For Multiple Use Model No Ceiling Panel CZ-18BT1U For Single useModel No Outdoor Unit Indoor Unit CS-KE12NB41For Multiple use Page 852-6-4190-585-00-1 For Indoor Unit ContentsPlease Read Before Starting Others When ServicingOptional Copper Tubing Kit Tools Required for Installation not suppliedAccessories Supplied with Unit Table General direct sunlight Installation Site SelectionAdditional Materials Required for Installation Indoor UnitEmbedding the Tubing and Wiring Placing the Unit Inside the Ceiling How to Install the Indoor UnitPreparation for Suspending Suspending the Indoor UnitDrain port Installing the Drain Piping Attach so that the hose band Fastener is on the side10a Checking the DrainageIndoor unit Gaps Ceiling surface Ceiling panel Installing the Ceiling PanelAttaching the air-intake grille Wiring the Ceiling Panel and the IndicatorWiring Instructions General precautions on wiring Checking After InstallationWhen Removing the Ceiling Panel for Servicing Adjusting the Auto Flap For stranded wiring How to connect wiring to the terminal For Indoor UnitFor Outdoor Unit  For solid core wiring or F-cable How to Test Run the Air Conditioner Mounting on a Wall Remote Controller Installation PositionRear side Remote control holder To take out the remote controller, pull it forwardAddress Setting of the Remote Controller Address SwitchInstallation Check Sheet Connecting a Home Automation DeviceCZ-RD515U Appendix DModel No. CZ-RD515U Operating Instructions Wired Remote ControllerAutomatic Switching between Cooling and Heating Installation Location SET button Timer and Present Time setting buttonsTimer Select button Remote Controller Display Automatic Operation Only for COOL/DRY/HEAT Model Heating Mode Only for COOL/DRY/HEAT Model Remote Controller Display910 pm 710 am 1130 pm Present time Backup functionProgrammed Daily on / OFFUsing the 1-HOUR OFF Timer Page Appendix E Installation Instructions CZ-RD515U Installation location Parts supplied with the remote controllerRemote controller installation guidelines How to install the remote controllerInstalling directly onto the wall Installing with in-wall junction boxHow to wire the remote controller WI1011-0 Page DC1111-0
Related manuals
Manual 69 pages 14.27 Kb Manual 132 pages 33 Kb Manual 124 pages 42.9 Kb Manual 56 pages 332 b

CZ-18BT1U, CS-KE18NB4UW, CS-MKE12NB4U, CU-3KE19NBU, CU-4KE24NBU specifications

The Panasonic CS-KE18NB4UW and CU-KE12NK1, along with the CS-KE12NB41, CZ-18BT1U, and CU-KE18NKU, represent a suite of advanced air conditioning solutions built with cutting-edge technologies designed to provide optimal comfort, energy efficiency, and air quality in various settings.

One of the standout features of this lineup is the inverter technology. Inverter air conditioners adjust the compressor speed to maintain the desired temperature efficiently. This leads to significant energy savings compared to traditional air conditioners, which tend to frequently cycle on and off, consuming more power. By continuously regulating the temperature, the Panasonic units not only save electricity but also prolong the lifespan of the compressor.

Another noteworthy characteristic is the nanoe™ technology integrated into some of these models. Nanoe™ technology uses hydroxyl radicals to purify the air, minimizing harmful bacteria and allergens. This makes the Panasonic units particularly suitable for users with allergies or respiratory issues, providing a cleaner and healthier indoor environment.

In terms of design, these models are sleek and compact, allowing them to fit seamlessly into any room decor, whether in a home, office, or commercial space. The quiet operation is another advantage, making them ideal for bedrooms and study areas where minimal noise is essential.

Furthermore, the CS-KE18NB4UW and CU-KE12NK1 offer a range of powerful cooling and heating capacities, making them versatile solutions for various climate conditions. The cold climate performance ensures consistent heating in colder regions, while the robust cooling capabilities make them perfect for hot summer months.

The user-friendly features include a smart remote control system, allowing users to adjust settings with ease from a distance. Some models are equipped with Wi-Fi capability, enabling integration with smart home systems for enhanced control and programmability.

In conclusion, the Panasonic CS-KE18NB4UW, CU-KE12NK1, CS-KE12NB41, CZ-18BT1U, and CU-KE18NKU air conditioning units exemplify innovation and efficiency. With their inverter technology, air purification features, compact designs, and smart functionalities, they stand out as ideal choices for maintaining comfortable and healthy indoor environments throughout the year.