INSTALLATION LOCATION

We recommend that this wired remote controller be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit.

• Do not install this wired remote controller where there are fumes or flammable gases, or in an extremely humid space such as a greenhouse.

Do not install the wired remote controller where excessively high heat-generating objects are placed.

Avoid:

To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa.

ELECTRICAL REQUIREMENTS

1.All wiring must conform to the local electrical codes. Consult your dealer or a qualified electrician for details.

2.Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring.

3.Wiring must be done by a qualified electrician.

NOTE

Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time.

SAFETY INSTRUCTIONS

Read this Instruction Manual carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.

This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in this Instruction Manual.

Confirm to authorized dealer or specialist on usage of specified refrigerant type.

Using of refrigerant other than the specified type may cause product damage, burst and injury etc.

Never touch the unit with wet hands.

Never use or store gasoline or other flammable vapor or liquid near the air conditioner — it is very dangerous.

Do not use this appliance in a potentially explosive atmosphere.

This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case.

Do not swallow the battery.

After removing the battery from remote controller, keep it away from the reach of children. The battery can cause death by suffocation if swallowed.

To prevent possible hazards from insulation failure, the unit must be grounded.

Do not clean inside the indoor and outdoor units by users. Engage authorized dealer or specialist for cleaning.

In case of malfunction of this appliance, do not repair by yourself. Contact to the sales dealer or service dealer for a repair.

Refrigerant gas leakage may cause fire.

For safety, be sure to turn the air conditioner off and

also to disconnect the power before cleaning.

Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency.

CAUTION

Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button.

Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high

speed.

• Do not touch the air inlet or the sharp aluminum fins of the outdoor unit. You may get injured.

Keep the fire alarm and the air outlet at least 1.5m away from the unit.

Do not let children play with the air conditioner.

Do not cool or heat the room too much if babies or invalids are present.

• Do not sit or step on the unit. You may fall down accidentally.

• Do not stick any object into the FAN CASE.

You may be injured and the unit may be damaged.

NOTICE

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

FCC Caution: To assure continued compliance, follow the attached installation instructions. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

3

Image 99
Contents 17,500BTU / h 11,900BTU / hSafety Precautions Prohibit Table of Contents CZ-RD515U Applicable MULTI-OUTDOOR Units Operating Range Temperature Indoor Air Intake Temp Outdoor Air Intake TempSpecifications Unit SpecificationsIndoor Unit CS-MKE9NB4U & CZ-18BT1U 208V Indoor UnitIndoor Unit CS-MKE12NB4U & CZ-18BT1U CS-MKE12NB4U & CZ-18BT1U Indoor Unit CS-KE18NB4UW & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1U Indoor Unit Panel CZ-18BT1U Major Component SpecificationsIndoor Unit Indoor Unit Body CS-MKE9NB4UCB-CS-MKE12NB4U Indoor Unit Body CS-MKE12NB4UCB-CS-KE18NB4U Indoor Unit Body CS-KE18NB4UWCS-MKE12NB4U & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1U Other Component SpecificationsView Dimensional DataIndoor Unit CS-KE18NB4UW & CZ-18BT1U Indoor unit Refrigerant Flow DiagramElectrical Data Electric Wiring DiagramsRemove the air intake grill MaintenanceDisassembly Procedure Disconnect the connectors in the control boxRemove the ceiling panel Remove the power box and control box Remove the indoor air temperature sensorScrew Ground cable CN07 CN03 CN09 CN06 Remove the main body lower section Remove the heat exchanger sensor Remove the drain pump and float switchRemove the heat exchanger Remove the turbo fan and fan motorAuto cooling/heating operation FunctionsOperation Functions Emergency operationLamp colors Timer backupCold-air prevention during heating Protective FunctionsOverload prevention during heating Freeze preventionTroubleshooting Before Calling for Service Precautions before Performing Inspection or RepairMethod of Self-Diagnostics Indoor Unit Self-diagnostics LampsReplace the circuit board or the fuse Using the TEST/T-RUN terminalsChecking the Indoor and Outdoor Units Replace the controllerCondition E01 Serial Communication Error Identification ProcedureOff Blinking Illuminated Before the OperationFrom the previous page a Condition E12 Indoor Fan Motor Trouble Diagnosis of Fan MotorLocations most susceptible to noise Trouble Correction Noise Malfunction and Electromagnetic InterferenceNoise malfunction Electromagnetic interferencePage CS-MKE9NB4U & CZ-18BT1U CS-MKE12NB4U & CZ-18BT1U Appendix aCZ-18BT1U Model No Indoor UnitsCeiling Panel Product Information FeaturesContents Safety PrecautionsAvoid Installation LocationSafety Instructions Electrical RequirementsUnit Display and Operation Button Names of PartsSymbols Remote Controller DisplayRemote Controller Sensor HR. Timer button 1-HOUR OFF TimerTemperature setting buttons Temp Mode selector buttonSingle/Multiple switch Using the Remote ControllerStep Operation with the Remote ControllerAutomatic Operation Manual OperationAdjusting the Fan Speed Night Setback ModeHigh Power Mode Special Remarks Setting the Timer1030 pm 710 am 1100 am Present time How to set the OFF timeHow to set the on time How to set daily ON/OFF repeat timerOperation together with the daily ON/OFF repeat timer Using the 1-HOUR OFF TimerAdjusting the Airflow Direction Hour OFF TimerCleaning the main unit and Remote Controller Care and CleaningWhen the air conditioner is not running Cleaning the flapsCare After a prolonged idle period How to remove the filterHow to remove the air intake grille Air filterTroubleshooting Wired Remote ControllerOperating Range Model No Ceiling Panel SpecificationsModel No Indoor Unit Model No Outdoor UnitCS-KE18NB4UW & CZ-18BT1U Appendix BCZ-18BT1U CS-KE12NB41CU-KE12NK1 CS-KE18NB4UW CU-KE18NKUFan Only Installation Location DRY orange, Cool green and FAN green Remote Controller Display Remote Controller FAN Using the Remote Controller Operation with the Remote Controller Fan Only Special Remarks How to set the OFF time Sweep Cool Drysweep FAN Heat Care and Cleaning Air filter Max Min For Single use For Multiple Use Model No Ceiling Panel CZ-18BT1U For Single useModel No Outdoor Unit Indoor Unit CS-KE12NB41For Multiple use Page 852-6-4190-585-00-1 For Indoor Unit ContentsPlease Read Before Starting Others When ServicingOptional Copper Tubing Kit Tools Required for Installation not suppliedAccessories Supplied with Unit Table General direct sunlight Installation Site SelectionAdditional Materials Required for Installation Indoor UnitEmbedding the Tubing and Wiring Placing the Unit Inside the Ceiling How to Install the Indoor UnitPreparation for Suspending Suspending the Indoor UnitDrain port Installing the Drain Piping Attach so that the hose band Fastener is on the side10a Checking the DrainageIndoor unit Gaps Ceiling surface Ceiling panel Installing the Ceiling PanelAttaching the air-intake grille Wiring the Ceiling Panel and the IndicatorWiring Instructions General precautions on wiring Checking After InstallationWhen Removing the Ceiling Panel for Servicing Adjusting the Auto FlapHow to connect wiring to the terminal For Indoor Unit For Outdoor Unit  For solid core wiring or F-cable For stranded wiring How to Test Run the Air Conditioner Mounting on a Wall Remote Controller Installation PositionRear side Remote control holder To take out the remote controller, pull it forwardAddress Setting of the Remote Controller Address SwitchInstallation Check Sheet Connecting a Home Automation DeviceCZ-RD515U Appendix DModel No. CZ-RD515U Operating Instructions Wired Remote ControllerAutomatic Switching between Cooling and Heating Installation Location SET button Timer and Present Time setting buttonsTimer Select button Remote Controller Display Automatic Operation Only for COOL/DRY/HEAT Model Heating Mode Only for COOL/DRY/HEAT Model Remote Controller Display910 pm 710 am 1130 pm Present time Backup functionProgrammed Daily on / OFFUsing the 1-HOUR OFF Timer Page Appendix E Installation Instructions CZ-RD515U Installation location Parts supplied with the remote controllerRemote controller installation guidelines How to install the remote controllerInstalling directly onto the wall Installing with in-wall junction boxHow to wire the remote controller WI1011-0 Page DC1111-0
Related manuals
Manual 69 pages 14.27 Kb Manual 132 pages 33 Kb Manual 124 pages 42.9 Kb Manual 56 pages 332 b

CZ-18BT1U, CS-KE18NB4UW, CS-MKE12NB4U, CU-3KE19NBU, CU-4KE24NBU specifications

The Panasonic CS-KE18NB4UW and CU-KE12NK1, along with the CS-KE12NB41, CZ-18BT1U, and CU-KE18NKU, represent a suite of advanced air conditioning solutions built with cutting-edge technologies designed to provide optimal comfort, energy efficiency, and air quality in various settings.

One of the standout features of this lineup is the inverter technology. Inverter air conditioners adjust the compressor speed to maintain the desired temperature efficiently. This leads to significant energy savings compared to traditional air conditioners, which tend to frequently cycle on and off, consuming more power. By continuously regulating the temperature, the Panasonic units not only save electricity but also prolong the lifespan of the compressor.

Another noteworthy characteristic is the nanoe™ technology integrated into some of these models. Nanoe™ technology uses hydroxyl radicals to purify the air, minimizing harmful bacteria and allergens. This makes the Panasonic units particularly suitable for users with allergies or respiratory issues, providing a cleaner and healthier indoor environment.

In terms of design, these models are sleek and compact, allowing them to fit seamlessly into any room decor, whether in a home, office, or commercial space. The quiet operation is another advantage, making them ideal for bedrooms and study areas where minimal noise is essential.

Furthermore, the CS-KE18NB4UW and CU-KE12NK1 offer a range of powerful cooling and heating capacities, making them versatile solutions for various climate conditions. The cold climate performance ensures consistent heating in colder regions, while the robust cooling capabilities make them perfect for hot summer months.

The user-friendly features include a smart remote control system, allowing users to adjust settings with ease from a distance. Some models are equipped with Wi-Fi capability, enabling integration with smart home systems for enhanced control and programmability.

In conclusion, the Panasonic CS-KE18NB4UW, CU-KE12NK1, CS-KE12NB41, CZ-18BT1U, and CU-KE18NKU air conditioning units exemplify innovation and efficiency. With their inverter technology, air purification features, compact designs, and smart functionalities, they stand out as ideal choices for maintaining comfortable and healthy indoor environments throughout the year.