This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.

For safe installation and trouble-free operation, you must:

Carefully read this instruction booklet before beginning.

Follow each installation or repair step exactly as shown.

Observe all local, state, and national electrical codes.

Pay close attention to all warning and caution notices given in this manual.

This symbol refers to a hazard or unsafe practice which can

WARNING result in severe personal injury or death.

This symbol refers to a hazard or unsafe practice which can

CAUTION result in personal injury or prod- uct or property damage.

If Necessary, Get Help

These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions.

In Case of Improper Installation

The manufacturer shall in no way be responsible for improp- er installation or maintenance service, including failure to follow the instructions in this document.

SPECIAL PRECAUTIONS

WARNING When Wiring

ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM.

‡'RQRWVXSSO\SRZHUWRWKHXQLWXQWLODOOZLULQJDQGWXELQJ are completed or reconnected and checked.

‡+LJKO\GDQJHURXVHOHFWULFDOYROWDJHVDUHXVHGLQWKLV system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death.

‡*URXQGWKHXQLW following local electrical codes.

‡&RQQHFWDOOZLULQJWLJKWO\/RRVHZLULQJPD\FDXVHRYHU heating at connection points and a possible fire hazard.

‡7RSUHYHQWSRVVLEOHKD]DUGVIURPLQVXODWLRQIDLOXUH

the unit must be grounded.

When Transporting

Be careful when picking up and moving the indoor and out- door units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin alu- minum fins on the air conditioner can cut your fingers.

When Installing…

Select an installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance.

…In a Ceiling or Wall

Make sure the ceiling/wall is strong enough to hold the unit’s weight. It may be necessary to construct a strong wood or metal frame to provide added support.

…In a Room

Properly insulate any tubing run inside a room to prevent “sweating” that can cause dripping and water damage to walls and floors.

 

 

 

Keep the fire alarm and the air

 

 

 

 

 

 

outlet at least 1.5 m away from

 

CAUTION

 

 

 

the unit.

 

 

 

 

 

 

 

When Connecting Refrigerant Tubing

‡ :KHQSHUIRUPLQJpiping work

 

do not mix air except for speci-

 

fied refrigerant (R410A) in

 

refrigeration cycle. It causes

 

capacity down, and risk of

 

explosion and injury due to

 

high tension inside the refrige-

WARNING

rant cycle.

‡ 5HIULJHUDQWJDVOHDNDJHPD\

 

 

cause fire.

‡'RQRWDGGRUUHSODFHUHIULJHUDQW other than specified type.

It may cause product damage, burst and injury etc.

‡9HQWLODWHWKHURRPZHOOLQWKHHYHQWWKDWUHIULJHUDQW gas leaks during the installation. Be careful not to allow contact of the refrigerant gas with a flame as this will cause the generation of poisonous gas.

‡'RQRWDGGDQ\UHIULJHUDQWDLURUVXEVWDQFHLQWRWKH refrigeration circuit other than the designated refrigerant (R410A). Adding anything other than the specified refrig- erant may cause the pressure to rise excessively in the refrigeration circuit, rupturing the circuit and causing injury or damage.

‡8VHDOOQHZWXELQJDQGIODUHQXWVWRPDNHWKHWXELQJFRQ nections. Using any previous parts (from R22-based sys- tems) may result in damage to the equipment, and may lead to the refrigeration circuit rupturing, causing a seri- ous accident.

2

Image 80
Contents 11,900BTU / h 17,500BTU / hSafety Precautions Prohibit Table of Contents CZ-RD515U Applicable MULTI-OUTDOOR Units Temperature Indoor Air Intake Temp Outdoor Air Intake Temp Operating RangeIndoor Unit CS-MKE9NB4U & CZ-18BT1U SpecificationsUnit Specifications Indoor Unit 208VIndoor Unit CS-MKE12NB4U & CZ-18BT1U CS-MKE12NB4U & CZ-18BT1U Indoor Unit CS-KE18NB4UW & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1U Major Component Specifications Indoor UnitIndoor Unit Body CS-MKE9NB4U Indoor Unit Panel CZ-18BT1UIndoor Unit Body CS-MKE12NB4U CB-CS-MKE12NB4UIndoor Unit Body CS-KE18NB4UW CB-CS-KE18NB4UOther Component Specifications CS-MKE12NB4U & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1UDimensional Data ViewRefrigerant Flow Diagram Indoor Unit CS-KE18NB4UW & CZ-18BT1U Indoor unitElectric Wiring Diagrams Electrical DataMaintenance Disassembly ProcedureDisconnect the connectors in the control box Remove the air intake grillRemove the ceiling panel Remove the indoor air temperature sensor Remove the power box and control boxScrew Ground cable CN07 CN03 CN09 CN06 Remove the main body lower section Remove the drain pump and float switch Remove the heat exchanger sensorRemove the turbo fan and fan motor Remove the heat exchangerFunctions Operation FunctionsEmergency operation Auto cooling/heating operationTimer backup Lamp colorsProtective Functions Overload prevention during heatingFreeze prevention Cold-air prevention during heatingMethod of Self-Diagnostics Troubleshooting Before Calling for ServicePrecautions before Performing Inspection or Repair Self-diagnostics Lamps Indoor UnitUsing the TEST/T-RUN terminals Checking the Indoor and Outdoor UnitsReplace the controller Replace the circuit board or the fuseSerial Communication Error Identification Procedure Off Blinking IlluminatedBefore the Operation Condition E01From the previous page a Condition E12 Trouble Diagnosis of Fan Motor Indoor Fan MotorNoise Malfunction and Electromagnetic Interference Noise malfunctionElectromagnetic interference Locations most susceptible to noise Trouble CorrectionPage Appendix a CS-MKE9NB4U & CZ-18BT1U CS-MKE12NB4U & CZ-18BT1UCeiling Panel CZ-18BT1UModel No Indoor Units Features ContentsSafety Precautions Product InformationInstallation Location Safety InstructionsElectrical Requirements AvoidNames of Parts Unit Display and Operation ButtonRemote Controller Display SymbolsRemote Controller HR. Timer button 1-HOUR OFF Timer Temperature setting buttons TempMode selector button SensorUsing the Remote Controller Single/Multiple switchOperation with the Remote Controller Automatic OperationManual Operation StepHigh Power Mode Adjusting the Fan SpeedNight Setback Mode Setting the Timer Special RemarksHow to set the OFF time How to set the on timeHow to set daily ON/OFF repeat timer 1030 pm 710 am 1100 am Present timeUsing the 1-HOUR OFF Timer Adjusting the Airflow DirectionHour OFF Timer Operation together with the daily ON/OFF repeat timerCare and Cleaning When the air conditioner is not runningCleaning the flaps Cleaning the main unit and Remote ControllerHow to remove the filter How to remove the air intake grilleAir filter Care After a prolonged idle periodOperating Range TroubleshootingWired Remote Controller Specifications Model No Indoor UnitModel No Outdoor Unit Model No Ceiling PanelAppendix B CS-KE18NB4UW & CZ-18BT1UCS-KE12NB41 CU-KE12NK1CS-KE18NB4UW CU-KE18NKU CZ-18BT1UFan Only Installation Location DRY orange, Cool green and FAN green Remote Controller Display Remote Controller FAN Using the Remote Controller Operation with the Remote Controller Fan Only Special Remarks How to set the OFF time Sweep Cool Drysweep FAN Heat Care and Cleaning Air filter Max Min For Single use For Multiple Use For Single use Model No Outdoor Unit Indoor UnitCS-KE12NB41 Model No Ceiling Panel CZ-18BT1UFor Multiple use Page 852-6-4190-585-00-1 Contents For Indoor UnitPlease Read Before Starting When Servicing OthersTools Required for Installation not supplied Accessories Supplied with Unit TableGeneral Optional Copper Tubing KitInstallation Site Selection Additional Materials Required for InstallationIndoor Unit  direct sunlightEmbedding the Tubing and Wiring How to Install the Indoor Unit Preparation for SuspendingSuspending the Indoor Unit Placing the Unit Inside the CeilingInstalling the Drain Piping  Attach so that the hose bandFastener is on the side Drain portChecking the Drainage 10aInstalling the Ceiling Panel Indoor unit Gaps Ceiling surface Ceiling panelWiring the Ceiling Panel and the Indicator Attaching the air-intake grilleChecking After Installation When Removing the Ceiling Panel for ServicingAdjusting the Auto Flap Wiring Instructions General precautions on wiring For stranded wiring How to connect wiring to the terminal For Indoor UnitFor Outdoor Unit  For solid core wiring or F-cable How to Test Run the Air Conditioner Remote Controller Installation Position Rear side Remote control holderTo take out the remote controller, pull it forward Mounting on a WallAddress Switch Address Setting of the Remote ControllerConnecting a Home Automation Device Installation Check SheetAppendix D CZ-RD515UOperating Instructions Wired Remote Controller Model No. CZ-RD515UAutomatic Switching between Cooling and Heating Installation Location Timer and Present Time setting buttons SET buttonTimer Select button Remote Controller Display Automatic Operation Only for COOL/DRY/HEAT Model Remote Controller Display Heating Mode Only for COOL/DRY/HEAT ModelBackup function ProgrammedDaily on / OFF 910 pm 710 am 1130 pm Present timeUsing the 1-HOUR OFF Timer Page Appendix E Installation Instructions CZ-RD515U Parts supplied with the remote controller Remote controller installation guidelinesHow to install the remote controller Installation locationInstalling with in-wall junction box Installing directly onto the wallHow to wire the remote controller WI1011-0 Page DC1111-0
Related manuals
Manual 69 pages 14.27 Kb Manual 132 pages 33 Kb Manual 124 pages 42.9 Kb Manual 56 pages 332 b

CZ-18BT1U, CS-KE18NB4UW, CS-MKE12NB4U, CU-3KE19NBU, CU-4KE24NBU specifications

The Panasonic CS-KE18NB4UW and CU-KE12NK1, along with the CS-KE12NB41, CZ-18BT1U, and CU-KE18NKU, represent a suite of advanced air conditioning solutions built with cutting-edge technologies designed to provide optimal comfort, energy efficiency, and air quality in various settings.

One of the standout features of this lineup is the inverter technology. Inverter air conditioners adjust the compressor speed to maintain the desired temperature efficiently. This leads to significant energy savings compared to traditional air conditioners, which tend to frequently cycle on and off, consuming more power. By continuously regulating the temperature, the Panasonic units not only save electricity but also prolong the lifespan of the compressor.

Another noteworthy characteristic is the nanoe™ technology integrated into some of these models. Nanoe™ technology uses hydroxyl radicals to purify the air, minimizing harmful bacteria and allergens. This makes the Panasonic units particularly suitable for users with allergies or respiratory issues, providing a cleaner and healthier indoor environment.

In terms of design, these models are sleek and compact, allowing them to fit seamlessly into any room decor, whether in a home, office, or commercial space. The quiet operation is another advantage, making them ideal for bedrooms and study areas where minimal noise is essential.

Furthermore, the CS-KE18NB4UW and CU-KE12NK1 offer a range of powerful cooling and heating capacities, making them versatile solutions for various climate conditions. The cold climate performance ensures consistent heating in colder regions, while the robust cooling capabilities make them perfect for hot summer months.

The user-friendly features include a smart remote control system, allowing users to adjust settings with ease from a distance. Some models are equipped with Wi-Fi capability, enabling integration with smart home systems for enhanced control and programmability.

In conclusion, the Panasonic CS-KE18NB4UW, CU-KE12NK1, CS-KE12NB41, CZ-18BT1U, and CU-KE18NKU air conditioning units exemplify innovation and efficiency. With their inverter technology, air purification features, compact designs, and smart functionalities, they stand out as ideal choices for maintaining comfortable and healthy indoor environments throughout the year.