3.3.3PLCHMR Module Installation

The installation kit provides a PLCHMR module P/N 40002083 that is mounted inside the Master Controller Enclosure. This module is mounted to four 2.5” high standoffs and has five (5) wires to connect to the Master Controller board.

3.3.3.1PLCHMR Module 2.5” Standoff Installation

Remove and save the four (4) 6-32 screws that secure the Master Controller to the enclosure’s bottom panel (Refer to Figure 3.3-1for exact screw locations). The four saved screws will be used in a later step to secure the PLCHMR module mounting plate to the standoffs.

3.3.3.2PLCHMR Module Power Supply Connections

The PLCHMR module receives 16VDC power from Terminal Block-8 located on the top left hand corner of the Master Controller PCB as shown in Figure 3.3-2. Note the orientation and locations of the two positions on the plug-in terminal with respect to the +16 and GND Labels shown on the Master Controller PCB. Remove the two position plug-in terminal and loosen both of the plug-in terminal’s screw sufficiently to install the PLCHMR module’s red and black wires. The red wire should be inserted into the screw terminal position labeled #2 as shown Figure 3.3-3which connects to the +16 contact on the Master Controller PCB. The black wire should be inserted into the screw terminal position labeled #1 as shown Figure 3.3-3which connects to the GND contact on the Master Controller PCB.

PLC Health Monitoring & Reporting Sys

3-5

Manual EPM40002083-001 Rev -

Image 22
Contents Manual Number EPM40002083-001 State Route Urbana, OH Phone 937 Fax 937ECO# History of RevisionsRev Comment Approved Date PreliminaryDisclaimers Installation & Power UP Table of ContentsSafety Information General Information MaintenanceTable of Figures 1 Plchmr ModuleSafety Information Safety and Workmanship AlertsQualified Personnel InterlocksAirport Systems Scope General DescriptionAirport Systems 1 Plchmr Module 2 Master Controller with Plchmr Module Installed 3 Model SGF-60E Flash Head Safety Precautions Airport Systems Airport Systems Specifications User Supplied Tools DAYInstallation Step Replace existing MCU PN- 40000328 with new MCU PN Plchmr Module Power Supply Connections 2 Plchmr Module Mounted on and Wired to Master Controller 3 Terminal Block- 8 +16V Red and GND -Black Wire Connections 4 StrobeGuard Control & Status Network Wiring Connections Step 40000324-001 Flash Head Status Reporting Relay Installation Wiring 1 PLCHMRs Output Relay connection Diagram Final Installation Check Power Up and System TestsAirport Systems 1 Master Controller Circuit Board Plchmr System Maintenance and Configuration Menus Airport Systems 2 HMS Maintenance Menu Hierarchy 3 HMS Maintenance Menu 4 HMS Light Configuration Menu 5 HMS Modify Light Menu 6 HMS Report Confguration Menu Day Mode Airport Systems Airport Systems Overall Description Plchmr Module Replacement Parts Description Part NumberLight Configuration Examples 1 Tower Example with 9 Flash Heads on Three Physical Tiers Airport Systems TRM #2 TRM #3 TRM #4 TRM #5 TRM #6 TRMTRM #7 Airport Systems 5 System Configuration with 24 Flash Heads using 8 relays

40002083 specifications

The Honeywell 40002083 is an advanced control system designed for industrial applications, primarily focusing on process control and automation. This device is a part of Honeywell's integrated portfolio that caters to various industries, including oil and gas, pharmaceuticals, and manufacturing. The 40002083 serves as a vital tool for optimizing operational efficiency and ensuring safety across multiple processes.

One of the standout features of the Honeywell 40002083 is its robust architecture, which supports a diverse range of input and output configurations. This flexibility allows the device to integrate seamlessly with existing systems, accommodating both legacy and modern equipment. The system supports various protocols and communication standards, ensuring connectivity with other devices and platforms. Additionally, it offers user-friendly interfaces for easier monitoring and control.

The Honeywell 40002083 is equipped with cutting-edge technologies to enhance its performance. One such technology is its advanced data analytics capability, which provides real-time insights into operational parameters. This feature empowers users to make informed decisions based on accurate data, ultimately improving productivity and reducing downtime. Furthermore, the device utilizes machine learning algorithms to optimize system performance over time by adapting to changing process conditions.

Another significant characteristic of the Honeywell 40002083 is its emphasis on safety and compliance. The device includes comprehensive safety features, ensuring that critical processes remain within safe operating limits. It also helps meet industry standards and regulations, making it a reliable choice for enterprises striving for compliance. The built-in redundancy mechanisms further enhance system reliability, reducing the risk of failures or unplanned outages.

Moreover, the Honeywell 40002083 supports extensive scalability, making it suitable for both small and large-scale operations. Whether an organization is expanding its facilities or upgrading its control systems, this device can easily accommodate new requirements without necessitating a complete overhaul.

In summary, the Honeywell 40002083 embodies a blend of flexibility, performance, and safety, making it a valuable addition to any industrial automation landscape. With its advanced features, cutting-edge technologies, and strong emphasis on reliability, it stands as a testament to Honeywell's commitment to providing innovative solutions for modern industrial challenges. This control system enables businesses to enhance operational efficiency, maintain compliance, and ensure a safer working environment.