Honeywell 40002083 Plchmr System Maintenance and Configuration Menus

Page 33

Airport Systems

Note: Before performing any tests of the Flash Head Reporting Relay wiring the system must be configured using the PLCHMR System Maintenance and Configuration Menus.

3.7PLCHMR System Maintenance and Configuration Menus

3.7.1PLCHMR System Maintenance & Configuration Menus Overview

The PLCHMR system must be configured as part of the on-site installation. The PLCHMR’s maintenance menus are used to view and modify the site specific configuration data. The maintenance menus use a text window interface along with a command entry prompt. The command entry prompt is posted at the bottom of terminal window and is marked with “maint>”. Configuration data in the maintenance menus contains information about the site’s lights, its reporting mechanism, and the facility information. The site’s light configuration data contains information on how many lights, which tiers the lights are located, and height above ground level. The reporting configuration will specify if the reports are to be made via Ethernet or relays. The facility information will include: the owner, contact number, address, FCC number, Altitude, Longitude, and Latitude.

The maintenance menu system has a hierarchical structure which begins with the Health Monitoring System (HMS) home maintenance menu (see Figure 3.7-2). The home maintenance menu is the initial menu presented after the maintenance login is completed. The home maintenance menu can be recognized by the “HMS Maintenance Menu” title along with its four numbered menu items (See Figure 3.7-3).

PLC Health Monitoring & Reporting Sys

3-16

Manual EPM40002083-001 Rev -

Image 33
Contents State Route Urbana, OH Phone 937 Fax 937 Manual Number EPM40002083-001Rev Comment History of RevisionsECO# Approved Date PreliminaryDisclaimers Safety Information General Information Table of ContentsInstallation & Power UP Maintenance1 Plchmr Module Table of FiguresSafety and Workmanship Alerts Safety InformationInterlocks Qualified PersonnelAirport Systems General Description ScopeAirport Systems 1 Plchmr Module 2 Master Controller with Plchmr Module Installed 3 Model SGF-60E Flash Head Safety Precautions Airport Systems Airport Systems Specifications DAY User Supplied ToolsInstallation Step Replace existing MCU PN- 40000328 with new MCU PN Plchmr Module Power Supply Connections 2 Plchmr Module Mounted on and Wired to Master Controller 3 Terminal Block- 8 +16V Red and GND -Black Wire Connections 4 StrobeGuard Control & Status Network Wiring Connections Step 40000324-001 Flash Head Status Reporting Relay Installation Wiring 1 PLCHMRs Output Relay connection Diagram Power Up and System Tests Final Installation CheckAirport Systems 1 Master Controller Circuit Board Plchmr System Maintenance and Configuration Menus Airport Systems 2 HMS Maintenance Menu Hierarchy 3 HMS Maintenance Menu 4 HMS Light Configuration Menu 5 HMS Modify Light Menu 6 HMS Report Confguration Menu Day Mode Airport Systems Airport Systems Overall Description Plchmr Module Description Part Number Replacement PartsLight Configuration Examples 1 Tower Example with 9 Flash Heads on Three Physical Tiers Airport Systems TRM TRM #2 TRM #3 TRM #4 TRM #5 TRM #6TRM #7 Airport Systems 5 System Configuration with 24 Flash Heads using 8 relays

40002083 specifications

The Honeywell 40002083 is an advanced control system designed for industrial applications, primarily focusing on process control and automation. This device is a part of Honeywell's integrated portfolio that caters to various industries, including oil and gas, pharmaceuticals, and manufacturing. The 40002083 serves as a vital tool for optimizing operational efficiency and ensuring safety across multiple processes.

One of the standout features of the Honeywell 40002083 is its robust architecture, which supports a diverse range of input and output configurations. This flexibility allows the device to integrate seamlessly with existing systems, accommodating both legacy and modern equipment. The system supports various protocols and communication standards, ensuring connectivity with other devices and platforms. Additionally, it offers user-friendly interfaces for easier monitoring and control.

The Honeywell 40002083 is equipped with cutting-edge technologies to enhance its performance. One such technology is its advanced data analytics capability, which provides real-time insights into operational parameters. This feature empowers users to make informed decisions based on accurate data, ultimately improving productivity and reducing downtime. Furthermore, the device utilizes machine learning algorithms to optimize system performance over time by adapting to changing process conditions.

Another significant characteristic of the Honeywell 40002083 is its emphasis on safety and compliance. The device includes comprehensive safety features, ensuring that critical processes remain within safe operating limits. It also helps meet industry standards and regulations, making it a reliable choice for enterprises striving for compliance. The built-in redundancy mechanisms further enhance system reliability, reducing the risk of failures or unplanned outages.

Moreover, the Honeywell 40002083 supports extensive scalability, making it suitable for both small and large-scale operations. Whether an organization is expanding its facilities or upgrading its control systems, this device can easily accommodate new requirements without necessitating a complete overhaul.

In summary, the Honeywell 40002083 embodies a blend of flexibility, performance, and safety, making it a valuable addition to any industrial automation landscape. With its advanced features, cutting-edge technologies, and strong emphasis on reliability, it stands as a testament to Honeywell's commitment to providing innovative solutions for modern industrial challenges. This control system enables businesses to enhance operational efficiency, maintain compliance, and ensure a safer working environment.