■PROTECTOR

English

9. Maintenance

MA8

(2)

(1)

 

PROTECTOR

When you replace protector, use new bolts (T3207- 24130). (MA8)

Tightning Torque: 35~52in-lbs(4.0~6.0N.m.)

(1)Protector

(2)Bolt

MA9

PROCEDURES TO BE PERFORMED AFTER

EVERY 100 HOURS OF USE

1.Remove the muffler, insert a screwdriver into the vent, and wipe away any carbon buildup. Wipe away any carbon buildup on the muffler exhaust vent and cylinder exhaust port at the same time.

2.Tighten all screws, bolts, and fittings.

3.Check to see if any oil or grease has worked its way in between the clutch lining and drum, and if it has wipe it away using oil-free, lead-free gasoline.

English

10. Storage

Aged fuel is one of major causes of engine starting failure. Before storing the unit, empty the fuel tank and run the engine until it uses all the fuel left in the fuel line and the carburetor. Store the unit indoor taking necessary measures for rust prevention.