3.4Flash Head Status Reporting Relay Installation Wiring

The PLCHMR features eight (8) configurable status reporting outputs. Each output connects to a form-c relay via three screw terminal connections. Each screw terminal connection is uniquely tied to one of the relay’s contacts. In accordance with Figure

3.4-1:

1)Terminal labeled #1 connects to the normally-open contact

2)Terminal labeled #2 connects to the common contact

3)Terminal labeled #3 connects to the normally-closed contact,

Typically each discrete alarm reporting connections is made to the site’s alarm monitoring system uses terminals 1 & 2. Using the typical connection ensures that a fail/fault indication is reported in the event that power is interrupted to the SG-60 High Intensity Strobe Light System.

Each relay’s state is controlled uniquely by its software Tier Reporting Mechanism (TRM). The TRM is software configurable and enables the operator via a menu to combine tier related flash-heads into a group that can be associated with a TRM. (See Section 3.7.3 for additional details on software configuration)

The two operating states (activated/deactivated) of each relay represent the state of its corresponding TRM. The TRM’s two states are Flash/OK and Fail/Fault. The TRM state FLASH/OK represents a normal operation alarm level and is indicated by an activated relay. The TRM state Fail/Fault represents an abnormal operation alarm level and is indicated by a deactivated relay.

For example:

Assume that all the flash-heads on tier #1 are operating normally when some event causes a tier’s flash-head to malfunction. While all of the flash-heads on tier 1 are ok, TRM #1 is set to FLASH/OK and relay #1 is activated. After the fault event occurs causing a flash-head on the tier to malfunction, then TRM #1 would automatically change to the Fail/Fault state which would de-activate relay #1.

An activated relay cause the normally-open contact to be closed allowing any signal applied to the common contact(#2) to appear on the normally-open contact (#1). For a deactivated relay the normally-close contact is closed allowing any signal applied to the common contact (#2) to appear normally-closed contact (#3).

PLC Health Monitoring & Reporting Sys

3-11

Manual EPM40002083-001 Rev -

Image 28
Contents Manual Number EPM40002083-001 State Route Urbana, OH Phone 937 Fax 937History of Revisions Rev CommentECO# Approved Date PreliminaryDisclaimers Table of Contents Safety Information General InformationInstallation & Power UP MaintenanceTable of Figures 1 Plchmr ModuleSafety Information Safety and Workmanship AlertsQualified Personnel InterlocksAirport Systems Scope General DescriptionAirport Systems 1 Plchmr Module 2 Master Controller with Plchmr Module Installed 3 Model SGF-60E Flash Head Safety Precautions Airport Systems Airport Systems Specifications User Supplied Tools DAYInstallation Step Replace existing MCU PN- 40000328 with new MCU PN Plchmr Module Power Supply Connections 2 Plchmr Module Mounted on and Wired to Master Controller 3 Terminal Block- 8 +16V Red and GND -Black Wire Connections 4 StrobeGuard Control & Status Network Wiring Connections Step 40000324-001 Flash Head Status Reporting Relay Installation Wiring 1 PLCHMRs Output Relay connection Diagram Final Installation Check Power Up and System TestsAirport Systems 1 Master Controller Circuit Board Plchmr System Maintenance and Configuration Menus Airport Systems 2 HMS Maintenance Menu Hierarchy 3 HMS Maintenance Menu 4 HMS Light Configuration Menu 5 HMS Modify Light Menu 6 HMS Report Confguration Menu Day Mode Airport Systems Airport Systems Overall Description Plchmr Module Replacement Parts Description Part NumberLight Configuration Examples 1 Tower Example with 9 Flash Heads on Three Physical Tiers Airport Systems TRM #2 TRM #3 TRM #4 TRM #5 TRM #6 TRMTRM #7 Airport Systems 5 System Configuration with 24 Flash Heads using 8 relays

40002083 specifications

The Honeywell 40002083 is an advanced control system designed for industrial applications, primarily focusing on process control and automation. This device is a part of Honeywell's integrated portfolio that caters to various industries, including oil and gas, pharmaceuticals, and manufacturing. The 40002083 serves as a vital tool for optimizing operational efficiency and ensuring safety across multiple processes.

One of the standout features of the Honeywell 40002083 is its robust architecture, which supports a diverse range of input and output configurations. This flexibility allows the device to integrate seamlessly with existing systems, accommodating both legacy and modern equipment. The system supports various protocols and communication standards, ensuring connectivity with other devices and platforms. Additionally, it offers user-friendly interfaces for easier monitoring and control.

The Honeywell 40002083 is equipped with cutting-edge technologies to enhance its performance. One such technology is its advanced data analytics capability, which provides real-time insights into operational parameters. This feature empowers users to make informed decisions based on accurate data, ultimately improving productivity and reducing downtime. Furthermore, the device utilizes machine learning algorithms to optimize system performance over time by adapting to changing process conditions.

Another significant characteristic of the Honeywell 40002083 is its emphasis on safety and compliance. The device includes comprehensive safety features, ensuring that critical processes remain within safe operating limits. It also helps meet industry standards and regulations, making it a reliable choice for enterprises striving for compliance. The built-in redundancy mechanisms further enhance system reliability, reducing the risk of failures or unplanned outages.

Moreover, the Honeywell 40002083 supports extensive scalability, making it suitable for both small and large-scale operations. Whether an organization is expanding its facilities or upgrading its control systems, this device can easily accommodate new requirements without necessitating a complete overhaul.

In summary, the Honeywell 40002083 embodies a blend of flexibility, performance, and safety, making it a valuable addition to any industrial automation landscape. With its advanced features, cutting-edge technologies, and strong emphasis on reliability, it stands as a testament to Honeywell's commitment to providing innovative solutions for modern industrial challenges. This control system enables businesses to enhance operational efficiency, maintain compliance, and ensure a safer working environment.