Honeywell 40002083 Final Installation Check, Power Up and System Tests

Page 30

Airport Systems

3.5Final Installation Check

Before applying power to the equipment, perform the procedures in the following sections. If any test does not pass, please consult Sections 3.3.3.2 and 3.3.3.4 in this manual or call Honeywell Technical Support at (805) 581-5591.

3.5.1Preliminary

1.Verify that all AC input power circuit breakers are turned off.

2.Check that the MCU on the Master Controller’s printed circuit boards is properly seated in its socket.

3.Check that any user-installed wiring does not interfere with relay operation when covers are closed.

4.Check that replacement MCUs have been installed in all Flash-heads. Check that all Flash-head covers are shut properly for a weather-tight seal with all latches closed.

5.Set Master Controller switches as follows:

POWER SWITCH ------------------------------------------------------------------

OFF

LOCAL / REMOTE Switch ---------------------------------------------------

LOCAL

MODE Switch -----------------------------------------------------------------------

DAY

3.5.2Verify Correct Wiring from the PLCHMR Module to Master Controller

Check that power supply and StrobeGuard Network connectors on the printed circuit boards are properly seated in their sockets (Re-Verify that Sections 3.3.3.2 and 3.3.3.4 were performed correctly).

3.6Power Up and System Tests

During the power up of the system, there are two LED lights, which will be checked to verify correct operation and installation. The following is a description of all the indicators on PLCHMR.

3.6.1PLCHMR Status Indicators

Power Status Indicators (Figure 2.2-1)

ƒRed LED after power-up indicates Single Board Computer Fault

ƒGreen LED indicates Power is OK

3.6.2System Power Up

All switches and indicators listed in this section are in the Master Controller, except for the external system circuit breakers.

PLC Health Monitoring & Reporting Sys

3-13

Manual EPM40002083-001 Rev -

Image 30
Contents Manual Number EPM40002083-001 State Route Urbana, OH Phone 937 Fax 937ECO# History of RevisionsRev Comment Approved Date PreliminaryDisclaimers Installation & Power UP Table of ContentsSafety Information General Information MaintenanceTable of Figures 1 Plchmr ModuleSafety Information Safety and Workmanship AlertsQualified Personnel InterlocksAirport Systems Scope General DescriptionAirport Systems 1 Plchmr Module 2 Master Controller with Plchmr Module Installed 3 Model SGF-60E Flash Head Safety Precautions Airport Systems Airport Systems Specifications User Supplied Tools DAYInstallation Step Replace existing MCU PN- 40000328 with new MCU PN Plchmr Module Power Supply Connections 2 Plchmr Module Mounted on and Wired to Master Controller 3 Terminal Block- 8 +16V Red and GND -Black Wire Connections 4 StrobeGuard Control & Status Network Wiring Connections Step 40000324-001 Flash Head Status Reporting Relay Installation Wiring 1 PLCHMRs Output Relay connection Diagram Final Installation Check Power Up and System TestsAirport Systems 1 Master Controller Circuit Board Plchmr System Maintenance and Configuration Menus Airport Systems 2 HMS Maintenance Menu Hierarchy 3 HMS Maintenance Menu 4 HMS Light Configuration Menu 5 HMS Modify Light Menu 6 HMS Report Confguration Menu Day Mode Airport Systems Airport Systems Overall Description Plchmr Module Replacement Parts Description Part NumberLight Configuration Examples 1 Tower Example with 9 Flash Heads on Three Physical Tiers Airport Systems TRM TRM #2 TRM #3 TRM #4 TRM #5 TRM #6TRM #7 Airport Systems 5 System Configuration with 24 Flash Heads using 8 relays

40002083 specifications

The Honeywell 40002083 is an advanced control system designed for industrial applications, primarily focusing on process control and automation. This device is a part of Honeywell's integrated portfolio that caters to various industries, including oil and gas, pharmaceuticals, and manufacturing. The 40002083 serves as a vital tool for optimizing operational efficiency and ensuring safety across multiple processes.

One of the standout features of the Honeywell 40002083 is its robust architecture, which supports a diverse range of input and output configurations. This flexibility allows the device to integrate seamlessly with existing systems, accommodating both legacy and modern equipment. The system supports various protocols and communication standards, ensuring connectivity with other devices and platforms. Additionally, it offers user-friendly interfaces for easier monitoring and control.

The Honeywell 40002083 is equipped with cutting-edge technologies to enhance its performance. One such technology is its advanced data analytics capability, which provides real-time insights into operational parameters. This feature empowers users to make informed decisions based on accurate data, ultimately improving productivity and reducing downtime. Furthermore, the device utilizes machine learning algorithms to optimize system performance over time by adapting to changing process conditions.

Another significant characteristic of the Honeywell 40002083 is its emphasis on safety and compliance. The device includes comprehensive safety features, ensuring that critical processes remain within safe operating limits. It also helps meet industry standards and regulations, making it a reliable choice for enterprises striving for compliance. The built-in redundancy mechanisms further enhance system reliability, reducing the risk of failures or unplanned outages.

Moreover, the Honeywell 40002083 supports extensive scalability, making it suitable for both small and large-scale operations. Whether an organization is expanding its facilities or upgrading its control systems, this device can easily accommodate new requirements without necessitating a complete overhaul.

In summary, the Honeywell 40002083 embodies a blend of flexibility, performance, and safety, making it a valuable addition to any industrial automation landscape. With its advanced features, cutting-edge technologies, and strong emphasis on reliability, it stands as a testament to Honeywell's commitment to providing innovative solutions for modern industrial challenges. This control system enables businesses to enhance operational efficiency, maintain compliance, and ensure a safer working environment.