Omega Engineering OS533E manual OS530LE

Page 9

1General Description

The thermometer is easy to use:

Units have standard “V” groove aiming sights.

Integral tripod mount permits hands-free operation, if necessary.

Temperature readings are switchable from °F to °C via the keypad.

Parameters, such as target material emissivity and alarm setpoints, can be set and remain in memory until reset.

This instrument has a rugged and functional design, including:

Sealed keypad display.

Convenient trigger operation.

Soft carrying case and wrist strap, for safety and ease of carrying.

Rubber boot around the lens and the display.

Table 1-1. OS530 Series Handheld Infrared Thermometer Features

Features

OS530LE

OS532E

OS533E

OS534E

OS534E-LR

Accuracy*

±1% rdg

±1% rdg

±1% rdg

±1% rdg

±1% rdg

 

 

 

 

 

Range

-10 to 1000°F -10 to 1000°F

-10 to 1000°F

-10 to 1600°F

-10 to 1600°F

 

-23 to 538°C

-23 to 538°C

-23 to 538°C

-23 to 871°C

-23 to 871°C

Emissivity

adjustable

adjustable

adjustable

adjustable

adjustable

 

 

 

 

 

 

Backlit Dual Display

standard

standard

standard

standard

standard

 

 

 

 

 

 

Distance to Spot

 

 

 

 

 

Size Ratio

10:1

10:1

20:1

30:1

110:1

Differential Temp.

standard

standard

standard

standard

standard

 

 

 

 

 

 

Min/Max Temperature

standard

standard

standard

standard

standard

 

 

 

 

 

 

Average Temperature

standard

standard

standard

standard

standard

 

 

 

 

 

 

High Alarm

standard

standard

standard

standard

standard

 

 

 

 

 

 

Thermocouple Input

standard

standard

standard

standard

 

 

 

 

 

 

Audible Alarm

 

 

 

 

 

& Indicator

standard

standard

standard

standard

standard

Analog Output

1mV/deg

1mV/deg

1mV/deg

1mV/deg

1mV/deg

 

 

 

 

 

 

Built-in Laser Sighting

dot/circle

dot/circle

dot/circle

dot/circle

dot/circle

 

 

 

 

 

 

Trigger Lock

standard

standard

standard

standard

standard

 

 

 

 

 

 

Last Temp. Recall

standard

standard

standard

standard

standard

 

 

 

 

 

 

Low Alarm

standard

standard

standard

 

 

 

 

 

 

Ambient Target

 

 

 

 

 

Temperature

standard

standard

standard

Compensation

 

 

 

 

 

RS232 Interface

standard

standard

standard

 

 

 

 

 

 

Data Storage

standard

standard

 

 

 

 

 

 

Distance Measurement

 

 

Optional

 

 

 

 

 

 

 

 

1-2

Image 9
Contents User’sGuide Servicing North America Unpacking Instructions Accessories Page Unpacking Instructions Chapter General Description Chapter Maintenance General Description Introduction OS530LE OS530HRE OS530LE-CF OS533E-CF OS534E-CF Features OS523E OS524E LCD Parts of the Thermometer Front of the ThermometerKey General Description General Description Installing the Batteries Ac Power OperationField of View Positions Operating the ThermometerField of View OS534E, OS523E-1 Field of View OS53xE-CF Field of View OS523E-3 Measurement Techniques 11 Recorder Hookup 12. General Operational Block Diagram Real Time Mode Active OperationReal Time Modes 13. Visual Function Flow Chart Adjusting Emissivity Using the Lock FunctionUsing the Trigger Function Must be hard, flat, and reflective to ultrasonic pulse Using the Distance FunctionDS = 17. Field of View of Distance Meter HH-DM Laser Sighting Status Calculating Temperature ValuesChanging the Temperature from F to C or vice Versa Turning on the Display BacklightingThermocouple Input OS532E, OS533E, OS534E Using the Alarm Functions To set the low alarm value OS533E, OS534E, OS523E, OS524E Use the Ambient Target Temperature Compensation Atcf Operation PC User Application, OS530 Series19. Main Menu 10. Settings Menu Settings Menus21. Typical Temperature Data File Ascii PC Interface CommandsString Description Storing Temperature Data on Command OS534E, OS523E, OS524E Logging Temperature Data in Real Time OS523E, OS524E,OS534E Erasing the Temperature Data from Memory Mode Recall Mode Passive OperationRecall Modes Reviewing the Last Parameters Laser Sighting Right Side View DescriptionOperating the Laser Sighting Two Laser ConfigurationsLines of Sight of the Laser Sighting and Thermometer Sighting Scope Installing and Operating the Sighting ScopeInstalling the Sighting Scope Maintenance Replacing the Batteries Safety WarningCleaning the Lens Calibrating the ThermometerServicing the Laser Sighting Problem Solution Troubleshooting GuideTroubleshooting Guide Problem Troubleshooting Guide Specifications Specifications are for all models except where notedGND With Built-in Distance Module Laser Sighting Distance Measuring Built-in-DM Specifications Glossary of Key Strokes Glossary of Key Strokes Appendix How Infrared Thermometry Works a Thermal RadiationBlackbody Calculating Temperature Optics Field of View Appendix Emissivity Values MetalsNonmetals Appendix Determining an Unknown Emissivity Figure C-1. Determining Emissivity Figure C-2. Determining Emissivity with a Drilled Hole Appendix Determining an Unknown Emissivity Index Field of View Diagrams Recall WARRANTY/DISCLAIMER PH/CONDUCTIVITY Temperature