Omega Engineering GP901 manual Gauge Head Application Information, Tip, Pneumatic Gage Heads

Page 5

Gauge Head Application Information

When mounting the Gauge Head in a fixture, care must be taken as the linear bearing assembly at the tip end is made to very fine tolerances. If a high force is applied to the probe casing performance may be affected. Ideally probes should be clamped in a yoke, split or collar clamp. If single point screw clamping is adopted (see diagram), then a tightening torque (in Nm) should be limited to that which will give a maximum of 50Kg point load. The Gauge Head may be mounted in any attitude.

where

d = Screw dia. (mm)

 

P = Screw pitch (mm)

(assumes a V form thread and 0.15 coefficient of friction).

Typical maximum torque is 0.27 Nm (i.e. M5 x 0.8 steel or 10-32 UNF steel)

A clearance hole in the fixturing of 9.5 mm Φ is desirable around the gaiter for satisfactory operation.

Tip

Generally, where piece parts are automatically loaded into a fixture, or where there is the possibility of severe side loads, the use of pneumatically operated transducers is strongly recommended.

To remove the tip, the shaft should be fully retracted into the body before unscrewing.

Pneumatic Gage Heads

The tip of a pneumatic Gage Head is normally biased in the inward direction and the extension of the tip is achieved by applying air pressure to the Gauge Head nozzle.

Air pressure may be varied within the specified limits to achieve the desired tip force at zero. The pneumatic Gage Heads are designed to be leak free and of small volume to minimise the air flow requirements and maintain a consistent tip force. Care must be taken not to damage the gaiter seal as the satisfactory operation of the Gage Head is entirely dependent on this component. A clearance hole in the fixturing of 9.5 mm Φ is desirable around the gaiter for satisfactory operation.

To maximise working life of the Gage Heads the air supply should be both clean and dry for continual reliable operation. Maximum relative humidity of 60 % RH and filtered to better than 5 µm particle size.

Environmental Considerations

Most Gage Heads are designed to be used with a gaiter and are designed to withstand the rigours of in-process gauging and will operate satisfactorily in the presence of copious amounts of coolants and cleaning solvents.

For Gage Heads without a gaiter such as Feather touch or in situations where removal of the gaiter is necessary (i.e. at low temperatures where stiffening of the gaiter may be a problem) then the working atmosphere must be both clean and dry. Ingress of dirt or fluids may interfere with the performance of the probe or even cause damage.

GP901 M-3343 05/08

Image 5
Contents User’s Guide For immediate technical or application assistance Introduction Digital Probe SpecificationsDigital Probe Data GP901-05 GP901-1Pneumatic Operation Not GP901-05 version AccuracyTip Gauge Head Application InformationPneumatic Gage Heads Environmental ConsiderationsConnections CablePIE and T-CON Installation This Page Intentionally Left Blank This Page Intentionally Left Blank This Page Intentionally Left Blank WARRANTY/DISCLAIMER Temperature

GP901 specifications

The Omega Engineering GP901 is a notable addition to the realm of industrial instrumentation, specifically designed for high-performance applications in diverse settings. Engineered for accuracy and reliability, the GP901 is particularly well-suited for temperature measurement, boasting a robust set of features that cater to both novice and expert users in various industries.

At the core of the GP901's functionality is its advanced thermocouple technology, which provides highly accurate temperature readings across a wide range of applications. With the ability to measure temperatures from -200°C to 1372°C, the GP901 easily accommodates a variety of processes, from cryogenic environments to high-temperature industrial operations. This versatility makes the device a staple in sectors such as chemical processing, food and beverage production, and HVAC systems.

One of the standout features of the GP901 is its user-friendly interface. The device is equipped with a clear LCD display that ensures real-time monitoring of temperature readings, facilitating quick adjustments when required. Its intuitive design allows users to navigate through settings seamlessly, making configuration and calibration straightforward. This ease of use minimizes downtime, thereby enhancing operational efficiency.

Additionally, the GP901 includes robust connectivity options, allowing it to integrate into existing systems effortlessly. With compatibility for various sensors and communications protocols, including RS-232 and USB, the GP901 is capable of transmitting data to central control systems for further analysis and record-keeping. This capability is essential for industries that require stringent compliance with regulatory standards.

Durability is another hallmark of the GP901, as it features a rugged housing that is resistant to harsh environmental conditions. This makes the unit ideal for outdoor installations or areas with exposure to moisture, dust, or extreme temperatures. The device's design takes into consideration not only performance but also longevity, ensuring that it can withstand the rigors of industrial use.

In conclusion, the Omega Engineering GP901 stands out for its exceptional performance characteristics, user-friendly functionality, versatility in temperature measurement, and durable design. Its commitment to precision and reliability makes it an indispensable tool for professionals across various fields, solidifying its reputation as a leading choice in temperature measurement technology.