Panasonic CW-XC144HU, CW-XC104HK manual Installation, How to Install the Unit, Window Requirements

Page 10

Installation

How to Install the Unit

1.To prevent vibration and noise, make sure the unit is installed securely and firmly

2.Install the unit where the sunlight does not shine directly on the unit.

3.The outside of the cabinet must extend outward for at least 12" (30.5cm) and there should be no obstacles, such as a fence or wall, within 20" (50.8cm) from the back of the cabinet because it will prevent heat radiation of the condenser.

Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.

Cooled air

30"~60"

(76.2~152.4cm)

Fence

Awning

Heat radiation

About 1/2"(12.7mm)

Over 20"(50.8cm)

and Installation

CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure.

4.Install the unit a little slanted so the back is slightly lower than the front (about 1/2"(12.7mm)).

This will force condensed water to flow to the outside.

5.Install the unit with the bottom about 30"~60"(76.2~152.4cm) above the floor level.

Window Requirements

NOTE: All supporting parts should be secured to firm wood, masonry, or metal.

Features

This unit is designed for installation in standard double hung windows with actual opening widths from 27" to 39" (68.6~99.1cm).

The top and bottom window sash must open sufficiently to allow a clear vertical opening of 16" (40.6cm) from the bottom of the upper sash to the window stool.

27" to 39"

(68.6~99.1cm)

16" min (40.6cm) Stool (With frame curtain)

Interior wall 23 5/8" min.(60cm)

(Without frame curtain)

Offset

1/2" to 11/4"

(12.7~31.8mm)

Sill

Exterior

10

Image 10
Contents Manuel Dinstallation ET Dutilisation For Your Records Safety Precautions Be sure not to do this Be sure to follow the instructionsVentilate well when used About the Controls on the Air Conditioner ControlsRemote controller EconomyAir Direction How to Secure the Drain PipeVentilation Vertical AIR-DIRECTION ControlCare and Maintenance Air Filter CleaningFeatures FeaturesHow to Install the Unit InstallationWindow Requirements Installation Kits Contents Suggested Tool RequirementsCabinet Installation Very slight tilt about 1/212.7mmBottom PAN Line Cord Plug Use Wall Receptacle Power Supply Electrical DataSituations Where the Appliance will be Disconnected Often Electrical Safety Applies to USA and Puerto RicoUSE of Extension Cords Normal Operation Before you call for serviceAbnormal Operation Memo Enregistrement Mesures de sécurité AvertissementNe pas nettoyer le Climatiseur à grande eau Les commandes Instructions de fonctionnementTélécommande Économie DénergieAjuster la direction dair La ventilationComment utiliser le tuyau d’évacuation Nettoyage du filtre à air Nettoyage et entretienComment insérer les piles Caractéristiques CaractéristiquesChoisissez le meilleur emplacement Instructions pour linstallationConditions requises pour linstallation à la fenêtre Contenu de lensemble dinstallation Outils requis pour l’installationInstallation du boîtier RemarqueMise EN Garde NE Percez PAS UN Trou AU Données sur lélectricité Utilisation DE Cordons ProlongateursSituations OÙ Lappareil Devra Être Débranché Fréquemment Situations OÙ Lappareil Naura PAS À Être Débranché SouventLutilisation DE Cordons Prolongateurs Fonctionnement normal Avant de placer un appel de serviceFonctionnement anormal Nota Para SU Informacion Precauciones Importantes de Seguridad Precaucion Controles Control remoto Ahorrador DE EnergíaVentilación Como Installar el Tubo de DesagüeComo controlar la direccion del aire Limpieza de filtro de Aire Cuidado y MantenimientoCómo poner las baterías Características CaracterísticasElija el major lugar Instrucciones de InstalaciónRequistios de ventana Contenido del Juego de Instalación Requisitos de las herra mientas sugeridasInstalación del Gabinete NotaCaracterísticas e Instalacion Datos Electricos USO DE Cordones DE ExtensionInformacion ElectricaAplica a USA y Puerto Rico USO DE ExtensionesOperación normal Antes de avisar al Servicio TécnicoOperación anormal Memo Memo Memo Cooling Capacity CW-XC124HU CW-XC144HU Ref Acwar 11/03 Ref. AcwarFr 11/03 Panasonic Room Air Conditioner