Quantum 1107 owner manual On/Off Key, Battery Condition Meter, Lock Mode

Page 36
Figure 30. FLIGHT Controller Keypad

V I I . O P E R A T I O N

On/Off Key

 

BATTERY

The on/off key turns the FLIGHT on and off.

 

 

METER

 

 

CONDITION

WARNING! Unless faced with an emergency situation,

 

 

do not use the on/off key to stop the chair. This will

SETTING

 

cause the power chair to stop abruptly.

 

 

SPEED

 

 

INDICATOR

ON/OFF

WARNING! Always turn the power off when you are

 

KEY

TORTOISE

HARE

stationary to prevent unexpected movement.

KEY

KEY

 

 

HORN

Battery Condition Meter

HAZARD

KEY

LIGHT KEY

HEADLIGHT

(OPTIONAL)

KEY (OPTIONAL)

The battery condition meter consists of ten lights arranged in an arc

 

ACTUATOR LIGHTS

over the on/off key. As the battery voltage drops, the number of

INDICATOR LIGHT

INDICATOR LIGHT

lights reduces from right to left. When the battery capacity drops to

LEFT TURN

RIGHT TURN

10% or below, the left red LED will flash.

SIGNAL KEY

SIGNAL KEY

! Left Red LED Flashing: Battery charge is low; charge the

(OPTIONAL)

(OPTIONAL)

 

SEAT ACTUATOR

batteries as soon as possible.

 

 

KEY (OPTIONAL)

!Right-to-Left Ripple of LEDs: FLIGHT is in lock mode; un- lock the FLIGHT.

!Left-to-Right Ripple of LEDs Alternating with Steady Dis- play: FLIGHT is in programming, inhibit, or charging mode.

!Right Green LED Flashing: FLIGHT is in speed limit mode.

!All LEDs Flashing Slowly: The joystick was not in the neutral

position when the controller was turned on. If you get “all LEDs flashing slowly,” turn off the controller, allow the joystick to return to the neutral position, then turn on the controller.

!All LEDs Flashing Quickly: The FLIGHT has detected a fault; Refer to the Error Code table.

Lock Mode

The FLIGHT controller is equipped with a feature that enables you to “lockout” unauthorized users.

To lock the FLIGHT controller:

1.While the power is on, press and hold the on/off key for 2 seconds. The display will turn off immediately. After 2 seconds, all LEDs will flash briefly and the horn will sound a short beep.

2.The FLIGHT controller is now locked.

To unlock the FLIGHT controller:

1.While the FLIGHT is locked, press the on/off key to turn on the FLIGHT. All LEDs will flash briefly. The LEDs will then slowly ripple from right to left.

2.Press the horn key twice before the LED ripple has completed, approximately 10 seconds. The FLIGHT is now unlocked.

Actuator Keys and Actuator Lights (For Optional Equipment)

Actuator keys and actuator lights are used for optional equipment such as power elevating leg rests. For specific operation of the actuator keys and actuator lights, contact your Quantum Rehab Specialist.

36

www.quantumrehab.com

Quantum 1107

Image 36
Contents Page F E T Y G U I D E L I N E S N T E N T S IIISafety N T R O D U C T I O NPURCHASER’S Agreement Information ExchangePride Owners Club My Quantum Rehab SpecialistProduct Safety Symbols S a F E T YS a F E T Y Pre-Ride Safety Check ModificationsWeight Limitations Tire InflationIncline Information Braking Information Cornering InformationOutdoor Driving Surfaces Freewheel Mode Stationary Obstacles Steps, Curbs, etcPublic Streets and Roadways Stairs and Escalators Transfers Motor Vehicle TransportDoors Inclement Weather Precautions ElevatorsLift/Elevation Products Positioning BeltsPreventing Unintended Movement Removable Parts Batteries Prescription Drugs/Physical LimitationsAlcohol Electromagnetic and Radio Frequency Interference EMI/RFI I . Y O U R P O W E R C H a I R QuantumQuantum 1107 Specifications Quantum 1107 Power Base Electrical Components Quantum 1107 Electrical ComponentsManual Freewheel Levers To engage or disengage the drive motorsInitial Assembly A S S E M B L Y / D I S a S S E M B L YSeat Installation To install the seat initial installationTo remove the seat Power Base Disassembly To disassemble the power chairQuantum 1107 Battery Box Removal and Frame Separation Comfort Adjustments Seat Height and Seat Angle AdjustmentO M F O R T a D J U S T M E N T S To change the seat heightSeatback Angle Adjustment Manual Recline Seatback AdjustmentArmrest Width Adjustment Seat PositionArmrest Angle Adjustment To change the armrest widthTo change the armrest angle Controller PositionFoot Platform Height Adjustment Foot Platform Depth AdjustmentFoot Platform Angle Adjustment Quick Release FastenersSwing-away Footrests Elevating Leg Rests OptionalMulti-Axis Foot Plate Anti-Tip Wheels Adjustment O M F O R TB a T T E R I E S a N D C H a R G I N G Batteries and ChargingCharging the Batteries Battery Break-in Frequently Asked Questions FAQsTo break in new batteries for maximum efficiency How does the charger work?Can I use a different battery charger? Why do my new batteries seem weak?How often must I charge the batteries? Daily UseHow can I ensure maximum battery life? How should I store my power chair and its batteries?What about public transportation? What about shipping?I . O P E R a T I O N Flight ControllerFlight consists JoystickBattery Condition Meter Lock ModeOn/Off Key Actuator Keys and Actuator Lights For Optional EquipmentSleep Mode If Enabled Error CodesError Code Probable Cause Possible Solution Horn KeyVSI Electronic Controller VSI consistsRed lights only lit or slow flash Charge batteries as soon Speed/Profile KeysActuator Connector Optional Controller ConnectorLocking/Unlocking the VSI To lock the VSIVSI Error Codes Thermal RollbackRemote Plus Controller Remote Plus consists of the followingMode Key Speed Settings To select a speed settingRight/Left Turn Indicator Keys Optional Power Accessories/Power Accessory Indicator OptionalSleep Mode Light Key OptionalRemote Plus Error Codes Flashing Lights Diagnosis SolutionMicrodrive Controller Microdrive Controller consistsProfile and Speed Indicator Actuator IndicatorDisplay Pad Joystick Interface ModuleTo select a profile setting Speed AdjustmentDrive Profile Selection To change the speedFlashing Lights Diagnosis Solution Care and Maintenance Should your power chair come in contact with waterTemperature I I . C a R E a N D M a I N T E N a N C EDaily Checks Weekly ChecksMonthly Checks Yearly ChecksDisposal of Your Power Chair Cleaning and DisinfectionWheel Replacement Battery Replacement To replace the batteriesWhen to See Your Quantum Rehab Specialist for Service Corrective MaintenanceW a R R a N T Y Reconditioned Units Warranty Warranty ExclusionsService Checks and Warranty Service Exclusions also include components with damage caused byT E S T E S Quality Control Quantum
Related manuals
Manual 2 pages 6.57 Kb

1107 specifications

Quantum 1107 represents a significant advancement in the realm of quantum computing, designed to address the growing complexities of computational tasks across various industries. This cutting-edge system leverages quantum bits, or qubits, which form the foundation of its unique processing abilities, allowing for operations that significantly outpace traditional binary computing.

One of the standout features of the Quantum 1107 is its impressive qubit count. With over 100 qubits, it is engineered to handle intricate calculations and simulations that would take classical computers an impractical amount of time. Each qubit is constructed using superconducting materials, allowing for high coherence times that enhance reliability and performance. This stability is critical for executing precise operations, ultimately expanding the potential applications of quantum algorithms.

The Quantum 1107 employs a novel quantum error correction technology, which is essential for maintaining the integrity of quantum calculations. By continuously monitoring and correcting errors that may arise during computations, this system ensures that users can trust the results produced, facilitating more complex problem-solving without the usual risk of errors that plague many quantum computing systems.

Furthermore, the system implements advanced quantum entanglement protocols, enabling qubits to work together in ways that amplify processing power. This phenomenon allows for simultaneous computations that drastically reduce the time required to solve specific algorithms, such as those in optimization, cryptography, and complex simulations.

Quantum 1107 also features a user-friendly interface that simplifies the programming of quantum applications. With built-in support for high-level programming languages designed for quantum computing, researchers and developers can easily implement quantum algorithms without needing to delve into the underlying hardware intricacies.

Another aspect of the Quantum 1107 is its robust scalability. This system is designed to grow alongside technological advancements, allowing for seamless upgrades in qubit count and processing capabilities. As the field of quantum computing continues to evolve, the Quantum 1107 remains positioned to adapt, ensuring that users can leverage the latest innovations.

In summary, Quantum 1107 stands out in the quantum computing landscape due to its high qubit count, advanced error correction, and entanglement capabilities, combined with a user-friendly interface and scalability. These features make it an invaluable tool for researchers and industries seeking to unlock the transformative potential of quantum technology.