Thermal Rollback

The VSI controller is equipped with a thermal rollback circuit. This circuit monitors the temperature of the controller, which roughly translates to motor temperature. In the event that the VSI controller becomes excessively hot (above 140° F), motor current (amperage) is reduced. For every degree above 140° F, the motor current limit is reduced by .55 amps until the VSI controller reaches 158° F, at which time the current output is reduced to zero. This reduces your power chair’s “power,” which could also reduce your power chair’s speed, and allows the electrical components and motors to cool down. When the temperature returns to a safe level, your power chair resumes its normal operation.

VSI Error Codes

The VSI controller is designed with the user’s safety as the prime consideration. It incorporates many sophisticated self- test features which search for potential problems at a rate of 100 times per second. If the VSI detects a problem either in its own circuits or in the power chair’s electrical system, it may stop the power chair, depending on the severity of the problem. The VSI is designed to maximize the user’s safety under all normal conditions. The table below identifies the individual error codes. Error codes are displayed as a rapid flashing of the battery condition meter lights. If you get one of these error codes, contact your Quantum Rehab Specialist.

FLASHING LIGHTS

DIAGNOSIS AND SOLUTION

 

 

1

The batteries need charging or there is a bad connection to the batteries. Check the

 

connections to the batteries. If the connections are good, try charging the batteries.

 

 

2

The left motor has a bad connection. Check the left motor connection.

 

 

3

The left motor has a short circuit to a battery connection. Contact your Quantum Rehab

 

Specialist.

 

 

4

The right motor has a bad connection. Check the right motor connection.

 

 

5

The right motor has a short circuit to a battery connection. Contact your Quantum Rehab

 

Specialist.

 

 

6

The power chair is being inhibited by the battery charger. Unplug the battery charger.

 

 

7

A joystick fault is indicated. Make sure that the joystick is in the neutral (center) position

 

before turning on the controller.

 

 

8

A controller system fault is indicated. Make sure that all connections are secure.

 

 

9

The parking brakes have a bad connection. Check the parking brake and motor

 

connections. Make sure the controller connections are secure.

 

 

10

An excessive voltage has been applied to the controller. This is usually caused by a poor

 

battery connection. Check the battery connections.

 

 

 

 

Quantum 1107

www.quantumrehab.com

41

Image 41
Contents Page F E T Y G U I D E L I N E S III N T E N T SN T R O D U C T I O N SafetyPURCHASER’S Agreement Information ExchangeMy Quantum Rehab Specialist Pride Owners ClubS a F E T Y Product Safety SymbolsS a F E T Y Modifications Pre-Ride Safety CheckIncline Information Weight LimitationsTire Inflation Outdoor Driving Surfaces Braking InformationCornering Information Public Streets and Roadways Stairs and Escalators Freewheel ModeStationary Obstacles Steps, Curbs, etc Doors TransfersMotor Vehicle Transport Elevators Inclement Weather PrecautionsLift/Elevation Products Positioning BeltsAlcohol Preventing Unintended Movement Removable Parts BatteriesPrescription Drugs/Physical Limitations Electromagnetic and Radio Frequency Interference EMI/RFI Quantum I . Y O U R P O W E R C H a I RQuantum 1107 Specifications Quantum 1107 Power Base Quantum 1107 Electrical Components Electrical ComponentsTo engage or disengage the drive motors Manual Freewheel LeversA S S E M B L Y / D I S a S S E M B L Y Initial AssemblyTo remove the seat Seat InstallationTo install the seat initial installation To disassemble the power chair Power Base DisassemblyQuantum 1107 Battery Box Removal and Frame Separation Seat Height and Seat Angle Adjustment Comfort AdjustmentsO M F O R T a D J U S T M E N T S To change the seat heightManual Recline Seatback Adjustment Seatback Angle AdjustmentArmrest Width Adjustment Seat PositionTo change the armrest width Armrest Angle AdjustmentTo change the armrest angle Controller PositionFoot Platform Depth Adjustment Foot Platform Height AdjustmentFoot Platform Angle Adjustment Quick Release FastenersMulti-Axis Foot Plate Swing-away FootrestsElevating Leg Rests Optional O M F O R T Anti-Tip Wheels AdjustmentCharging the Batteries B a T T E R I E S a N D C H a R G I N GBatteries and Charging Frequently Asked Questions FAQs Battery Break-inTo break in new batteries for maximum efficiency How does the charger work?Why do my new batteries seem weak? Can I use a different battery charger?How often must I charge the batteries? Daily UseHow should I store my power chair and its batteries? How can I ensure maximum battery life?What about public transportation? What about shipping?Flight Controller I . O P E R a T I O NFlight consists JoystickLock Mode Battery Condition MeterOn/Off Key Actuator Keys and Actuator Lights For Optional EquipmentError Codes Sleep Mode If EnabledError Code Probable Cause Possible Solution Horn KeyVSI consists VSI Electronic ControllerSpeed/Profile Keys Red lights only lit or slow flash Charge batteries as soonController Connector Actuator Connector OptionalLocking/Unlocking the VSI To lock the VSIThermal Rollback VSI Error CodesRemote Plus consists of the following Remote Plus ControllerTo select a speed setting Mode Key Speed SettingsPower Accessories/Power Accessory Indicator Optional Right/Left Turn Indicator Keys OptionalSleep Mode Light Key OptionalFlashing Lights Diagnosis Solution Remote Plus Error CodesMicrodrive Controller consists Microdrive ControllerActuator Indicator Profile and Speed IndicatorDisplay Pad Joystick Interface ModuleSpeed Adjustment To select a profile settingDrive Profile Selection To change the speedFlashing Lights Diagnosis Solution Should your power chair come in contact with water Care and MaintenanceTemperature I I . C a R E a N D M a I N T E N a N C EWeekly Checks Daily ChecksMonthly Checks Yearly ChecksWheel Replacement Disposal of Your Power ChairCleaning and Disinfection To replace the batteries Battery ReplacementCorrective Maintenance When to See Your Quantum Rehab Specialist for ServiceW a R R a N T Y Warranty Exclusions Reconditioned Units WarrantyService Checks and Warranty Service Exclusions also include components with damage caused byT E S T E S Quality Control Quantum
Related manuals
Manual 2 pages 6.57 Kb

1107 specifications

Quantum 1107 represents a significant advancement in the realm of quantum computing, designed to address the growing complexities of computational tasks across various industries. This cutting-edge system leverages quantum bits, or qubits, which form the foundation of its unique processing abilities, allowing for operations that significantly outpace traditional binary computing.

One of the standout features of the Quantum 1107 is its impressive qubit count. With over 100 qubits, it is engineered to handle intricate calculations and simulations that would take classical computers an impractical amount of time. Each qubit is constructed using superconducting materials, allowing for high coherence times that enhance reliability and performance. This stability is critical for executing precise operations, ultimately expanding the potential applications of quantum algorithms.

The Quantum 1107 employs a novel quantum error correction technology, which is essential for maintaining the integrity of quantum calculations. By continuously monitoring and correcting errors that may arise during computations, this system ensures that users can trust the results produced, facilitating more complex problem-solving without the usual risk of errors that plague many quantum computing systems.

Furthermore, the system implements advanced quantum entanglement protocols, enabling qubits to work together in ways that amplify processing power. This phenomenon allows for simultaneous computations that drastically reduce the time required to solve specific algorithms, such as those in optimization, cryptography, and complex simulations.

Quantum 1107 also features a user-friendly interface that simplifies the programming of quantum applications. With built-in support for high-level programming languages designed for quantum computing, researchers and developers can easily implement quantum algorithms without needing to delve into the underlying hardware intricacies.

Another aspect of the Quantum 1107 is its robust scalability. This system is designed to grow alongside technological advancements, allowing for seamless upgrades in qubit count and processing capabilities. As the field of quantum computing continues to evolve, the Quantum 1107 remains positioned to adapt, ensuring that users can leverage the latest innovations.

In summary, Quantum 1107 stands out in the quantum computing landscape due to its high qubit count, advanced error correction, and entanglement capabilities, combined with a user-friendly interface and scalability. These features make it an invaluable tool for researchers and industries seeking to unlock the transformative potential of quantum technology.