Tanita BC-41 instruction manual Operating Instructions, Body Composition Analysis

Page 10

6.Operating Instructions

Body Composition Analysis

This explains the procedure when the printer function is turned on. Please be aware that the display may be different if the number of printouts is set to [0].

Do not wipe the equipment with corrosive chemicals (gasoline, cleaner, etc.). Please use a neutral detergent to clean the equipment.

When the equipment has been transferred to any location where there is a temperature difference of 20˚C or more, wait for at least two hours before using it.

In taking measurements, please keep the person away from the unit, who uses transmitters such as a mobile phone avoid causing margin errors.

WEIGHT

CLOTHES

~

MALE

FEMALE

 

ATHLETIC

STEP ON

kg

6. Set the Target Body Fat Ratio.

After you input the height, “GOAL” will

lb

cm

automatically flash on the display. Input the target

ft.in

body fat ratio desired using the numerical keys.

AGE

Example: 16% = Press [1] and [6].

% FAT

9% = Press [0] and [9].

* If the number of print outs is set to “0”, nothing will

be displayed.

* If the target body fat ratio is set to OFF, the target

body fat ratio will not be printed out.

• Before you start a body weight management

program and set the appropriate personal

body fat ratio, please consult your doctor.

~

WEIGHT

kg

CLOTHES

lb

MALE

cm

FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

WEIGHT

kg

CLOTHES

lb

MALE

cm

FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

1. Turn on the Power.

Press the [

ON

] key.

OFF

“0.0” will appear on the upper portion of the display.

2. Enter Clothes Weight.

Enter clothes weight using the numerical keys. Example: if the clothes weight is 2.0 kg, press [2], [.] and then [0].

When the data input is completed, the data will be displayed as a minus number.

Tanita is not responsible for setting the

appropriate target body fat ratio for specific

individuals.

• For details of the desirable body fat

percentage, please refer to the Technical Notes.

Male athletes may wish to select a single digit

body fat percentage as their target. However,

this is not recommended for Standard Adults, in

particular women, who should avoid becoming

excessively lean. Always consult a doctor about

the target body fat percentage most suitable for

your body type.

• Do not step on the Weighing Platform until the

 

 

WEIGHT

kg

Male

Female

CLOTHES

lb

 

 

STANDARD

STANDARD

MALE

cm

ATHLETIC

ATHLETIC

FEMALE

ft.in

 

 

 

 

ATHLETIC

AGE

 

 

STEP ON

% FAT

 

 

WEIGHT

kg

 

 

CLOTHES

lb

~

MALE

cm

FEMALE

ft.in

 

 

 

 

ATHLETIC

AGE

 

 

STEP ON

% FAT

 

WEIGHT

kg

 

CLOTHES

lb

~

MALE

cm

FEMALE

ft.in

 

 

ATHLETIC

AGE

 

STEP ON

% FAT

3. Select the Body Type.

Select the Body Type from Standard Male, Standard Female, Athletic Male and Athletic Female. Please use the Athletic key when the user is 17 years or older and also meets the following criteria.

See page 8 for Tanita’s definition of “Athlete.”

4.Enter Age.

*If the user is 32 years old or younger. Example: Press [3] and [2].

*If the user is 9 years old or younger Example: press [0] and [9].

*If ages 16 or less are entered, even if Athletic is selected for the Body Type, it will be automatically changed to Standard.

5.Enter Height.

Example: If the user’s height is 172 cm, please press [1], [7] and then [2].

WEIGHT

kg

WEIGHT

CLOTHES

lb

CLOTHES

MALE

cm

MALE

FEMALE

ft.in

FEMALE

ATHLETIC

AGE

ATHLETIC

STEP ON

% FAT

STEP ON

Posterior Electrodes

Anterior Electrodes

target body fat ratio setting has been

completed because the power may be

automatically turned off or the measurement

may be inaccurate.

 

* If you want to change the settings, please press the

 

[

] key and the procedure will go back to the

 

former step. Please re-enter the data.

 

7. After “88888” is displayed on the upper portion

kg

of the display, a flashing arrow will appear next

lb

to

STEP ON .

 

cm ft.in

AGE % FAT

8. Start Measurement.

Step on the Weighing Platform with bare feet so they touch the electrodes. Stand in a stable position without bending your knees.

Do not use the hand grips, as you will only be measuring your body weight this time.

18

19

Image 10
Contents Body Composition Analyzer Table of Contents AdvantagesUsage Conditions Safety NotesPower Source Storage ConditionsProduct Assembly and Components Membrane Switch Assembly InstructionsDigital display Connection and Installation Loading the Printer Paper Roll Preparation for UseMode Selection Setting Date and TimeSetting the date and time Setting the Original Mode N TStandard Athletic Operating Instructions Body Composition AnalysisWeight Only Function Based on NIH/WHO BMI Guidelines Explanation of the Print OutBody Fat Ranges for Standard Adults AgeClearing Paper Jams Components of the Printer Unit Clearing Paper JamsSpecifications TroubleshootingProblem List Signal lines and connection methodsOutput data format Transmission dataOutput data items Output data Ascii codeControl Commands Switching to Remote ModeError Codes Example of Use Switch on body composition analyzerSet tare weight Set genderDuring measurement ResettingCancel Measurement finishedCurrent IntroductionBody impedance measurement methods VoltageIntra-day fluctuations cyclic activity within a single day Causes of errors in impedance measurementsIntra-day fluctuations Weight Intra-day fluctuations Impedance valueNew Regression Formula for Basal Metabolic Rate BMR Weight vs REEInter-day changes FFM vs REEProduct specifications REE→BMRKowloon, Hong Kong