Tanita BC-41 instruction manual Switching to Remote Mode, Control Commands, Error Codes

Page 16

Output (Fat Monitor Mode) Format

Remote Mode

All types of data may be entered by connecting the BC-418 to a PC and switching to Remote mode.

Switching to Remote Mode

 

 

 

 

1. When the unit is switched off, press the [

ON

]

 

 

WEIGHT

kg

OFF

 

 

CLOTHES

lb

and [ ] keys simultaneously.

 

 

 

 

MALE

cm

Note The default setting is off.

 

 

FEMALE

ft.in

 

 

ATHLETIC

AGE

 

 

STEP ON

% FAT

 

 

 

 

 

 

 

 

 

 

Control Commands

When in Remote mode, the body fat analyzer may be operated remotely by sending control commands from a host.

 

U

?

 

CR

 

 

LF

 

 

 

 

 

 

U? : Confirm current setting

commands

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U0: Use cm/kg mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U

0

 

CR

 

 

LF

 

 

 

 

 

 

U

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U1: Use in/lb mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U

1

 

CR

 

 

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

?

 

 

 

 

 

 

 

 

 

 

 

D? : Confirm current setting

 

 

CR

 

 

LF

 

 

 

 

 

 

 

D

0

 

X

 

X

X . X

 

 

 

D0

: Set clothing weight (5-byte fixed length)

 

 

 

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1

: Set gender male = 1 female = 2

D

1

X

CR

 

LF

WEIGHT

kg

CLOTHES

lb

MALE

cm

FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

WEIGHT

kg

CLOTHES

lb

MALE

cm

FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

WEIGHT

kg

CLOTHES

lb

MALE

cm

FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

WEIGHT

kg

CLOTHES

lb

MALE

cm

FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

2.Press [0], [8].

3.Switch Remote mode on and off by pressing [1]

or [0].

[1]: Enables Remote mode

[0]: Disables Remote mode

4.Press [ ] to confirm.

5. Push the [

ON

] key.

OFF

Only "r S" will appear (standby display).

To switch off Remote mode, start Note from the beginning again and

select "OFF" at Step 3.

commands

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D2

: Set body type standard = 0 athlete = 2

D

2

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

CR

 

 

 

LF

 

 

 

 

 

 

 

 

 

 

D

3

 

X

 

X

X

X X

 

 

 

 

 

D3

: Set height (5-byte fixed length)

 

 

 

 

CR

 

LF

 

D

4

 

X

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D4

: Set age (2-byte fixed length)

 

CR

 

 

LF

 

 

 

 

 

 

 

 

D

6 X X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D6

: Set Target BF (2-byte fixed length)

 

CR

 

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

commands

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G1: Start measuring body fat

 

 

 

 

1

 

 

 

 

 

 

 

 

CR

LF

 

 

 

G

G

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G2: Measure weight only

 

CR

 

 

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHR$(01FH): Reset settings

Special

CHR$(01FH)

 

CR

 

 

LF

 

 

 

 

 

 

commands

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHR$(01EH): Cancel measurement

CHR$(01EH)

 

CR

 

 

LF

 

 

 

 

 

 

*All fixed-length data right aligned. Enter 0 for blanks.

Error Codes

If an error occurs, the body composition analyzer will send an error code to the host.

 

 

 

 

 

 

 

E00

: Attempted to start measuring without completing settings

E

0

0

CR

 

LF

 

E

0

1

 

 

 

 

E01

: Error in calculating body fat percentage

CR

LF

E

X

X

 

 

 

 

EXX :other error ’ body fat analyzer switches off

CR

LF

 

 

 

 

 

 

 

 

 

*See p.26 "7. Troubleshooting" for details of errors.

30

31

Image 16
Contents Body Composition Analyzer Table of Contents AdvantagesSafety Notes Power SourceUsage Conditions Storage ConditionsProduct Assembly and Components Membrane Switch Assembly InstructionsDigital display Connection and Installation Loading the Printer Paper Roll Preparation for UseMode Selection Setting Date and TimeSetting the date and time Setting the Original Mode N TStandard Athletic Operating Instructions Body Composition AnalysisWeight Only Function Explanation of the Print Out Body Fat Ranges for Standard AdultsBased on NIH/WHO BMI Guidelines AgeClearing Paper Jams Components of the Printer Unit Clearing Paper JamsTroubleshooting Problem ListSpecifications Signal lines and connection methodsTransmission data Output data itemsOutput data format Output data Ascii codeControl Commands Switching to Remote ModeError Codes Switch on body composition analyzer Set tare weightExample of Use Set genderResetting CancelDuring measurement Measurement finishedIntroduction Body impedance measurement methodsCurrent VoltageCauses of errors in impedance measurements Intra-day fluctuations WeightIntra-day fluctuations cyclic activity within a single day Intra-day fluctuations Impedance valueWeight vs REE Inter-day changesNew Regression Formula for Basal Metabolic Rate BMR FFM vs REEProduct specifications REE→BMRKowloon, Hong Kong