Panasonic WV-CW504F manual Set the detection sensitivity, Set the minimum size of objects detected

Page 17

Step 6

Set the detection sensitivity and the minimum size of objects detected. Perform the setup while viewing the detection result displayed on the screen.

Set the detection sensitivity

Move the cursor to "SENSITIVITY" and select one of the following options for the detection sensitivity: LOW (default)/MID/HIGH

Set the minimum size of objects detected

Move the cursor to "MIN SIZE" and select the minimum size of objects detected from the following: The size options will be displayed in a green frame in the center of the screen. In "OFF" position, any object will be detected regardless of its size.

Perform the setup while viewing the detection result displayed on the screen. OFF (default)/SMALL/MEDIUM/LARGE

Note:

The detection sensitivity and minimum size selected in this step will be applied to all the alarm actions selected in step 3.

The detection areas set in step 4 will be displayed as a white frame on the "SENSITIVITY" screen.

When a motion is detected, a blue frame appears and changes to a red frame after a given time (approx. 1 second.) on the

"SENSITIVITY" screen. In operation, an alarm signal is provided when the frame changes to red.

Perform the settings relating to the detection of appearance/disappearance of stationary objects

Perform the settings relating to the detection of appearance/disappearance of stationary objects as follows. Up to 4 appearances/ disappearances of stationary objects can be simultaneously detected. However, use of the scene change detection function decreases the maximum simultaneous detectable appearances/disappearances of stationary objects to 3.

Follow the procedure below.

"CAMERA SETUP" screen

"i-VMD SETUP" screen

"OBJECT" screen

"SENSITIVITY" screen

 

**CAMERA SETUP**

**i-VMD SETUP**(1)

**OBJECT DET**(1)

**SENSITIVITY**(1)

SCENE1

 

MOTION DET

 

 

REMOVAL AND LEFT BEHIND

MIN SIZE

OFF

 

 

ALC

ALC

OBJECT DET

ON

 

 

 

 

 

 

 

 

SHUTTER

OFF

SCENE CHANGE

OFF

 

DURATION TIME

10s

 

 

 

 

AGC

ON(HIGH)

INDICATOR

OFF

AREA

ALL

 

 

 

 

SENS UP

OFF

SENSITIVITY

 

 

 

 

 

 

WHITE BAL

ATW1

ALARM

CONT

 

 

 

 

 

 

 

DNR

HIGH

 

 

 

 

 

 

 

 

 

 

BW MODE

AUTO1

 

 

 

 

 

 

 

 

 

 

i-VMD

 

 

 

 

 

 

 

 

 

 

 

 

RET TOP END

 

RET TOP END

 

 

RET TOP END

 

RET TOP END

 

 

Step 1

Move the cursor to "i-VMD" and press the setting button.

The "i-VMD SETUP" screen appears.

Step 2

Move the cursor to "OBJECT DET" and press the setting button.

The "OBJECT DET" screen appears.

Step 3

Move the cursor to "DURATION TIME" and select the wait time of appearance/disappearance of stationary objects from the following. 10 s (default)/20 s/30 s/40 s

17

Image 17
Contents Operating Instructions Trademarks and registered trademarks PrefaceContents Setup item Description Reference Pages About the setup menusStep Basic operationScreen transition diagram Camera ID screen Camera title setting Camera IDTop screen Display positioning screenRegister a scene file SCENE1/SCENE2 Screen when SCENE1 is selectedScreen when SCENE2 is selected Camera Setup screen ALC Cont screen SUPER-D5 settingArea setting screen Light quantity control method selection ALCWhen not using the SUPER-D5 function When using the SUPER-D5 functionMask setting screen Electronic shutter setting ShutterWhite balance setting White BAL Gain control setting AGCElectronic sensitivity enhancement setting Sens UP Fine adjustment screen Manual fine adjustment of white balanceCamera Setup screen Camera Setup screen BW Mode screen Digital noise reduction function setting DNRBlack-and-white mode setting BW Mode VMD setting i-VMD Detect objects that move into the specified direction Perform the settings relating to the motion detectionDetect motion of objects Set the minimum size of objects detected Set the detection sensitivityMotion DET screen Object DET screen Set the detection areasCamera Setup screen VMD Setup screen Setting of scene change detectionConfigure alarm notification Configure frame displaySetting of the power supply synchronization LL mode Camera system setting System SetupFollow the procedure below System Setup screen Sync screen Synchronization method selection SyncZone setting screen Automatic adjustments of the focus LensPrivacy zone setting Privacy Zone Image stabilizer setting Stabilizer Pan/tilt setting screen Electronic zoom setting EL-ZOOMDisplay setting of vertical or horizonal flip UPSIDE-DOWN Back focus adjustment Back focus setting BACK-FOCUS SetupABF Auto Chroma level adjustment Chroma Gain Special menu setting Special SetupAperture level adjustment AP Gain Pedestal level adjustment PedestalSpecial Setup screen PIX OFF screen Default resetting Camera ResetFlaw compensation PIX OFF Serial number viewing SER.NOLanguage selection Language Setup Shortcut operation System controller operation Setting contentsSystem controller operation Setting contents Panasonic Sales Company Panasonic System Solutions CompanyPanasonic Canada Inc
Related manuals
Manual 44 pages 27.27 Kb

WV-CW504SK, WV-CW504S, WV-CW504F, WV-CW504FK specifications

Panasonic’s range of WV-CW504 series network cameras, including models WV-CW504FK, WV-CW504F, WV-CW504S, and WV-CW504SK, epitomizes advanced security technology tailored for both indoor and outdoor surveillance applications. These cameras are designed to provide high-definition video quality alongside a range of features that enhance usability and security, making them ideal for various environments, from retail to public spaces.

One of the standout features of the WV-CW504 series is its exceptional image quality, with a resolution of up to 1080p. This ensures crystal-clear video capture, even in challenging lighting conditions, thanks to the integration of advanced image processing technologies. The cameras are equipped with Wide Dynamic Range (WDR) technology, which balances exposure levels to ensure that both bright and dark areas of the scene are visible.

Panasonic's WV-CW504 models come with a built-in motorized zoom lens that allows users to remotely adjust the field of view without having to physically reposition the camera. This feature is crucial for applications where flexibility in monitoring specific areas is necessary. Additionally, the cameras support various viewing angles, which can be critical for comprehensive coverage in various environments.

In terms of connectivity, these network cameras support Power over Ethernet (PoE), allowing for easier installation as they can receive power and data through a single cable. This significantly reduces installation costs and complexities, making these cameras an attractive choice for both new installations and upgrades to existing systems.

The WV-CW504 series also integrates advanced video analytics features, such as motion detection and tampering detection. These functionalities help optimize security monitoring by alerting users to unusual activity and allowing for a more proactive approach to surveillance management. Furthermore, the cameras support ONVIF compliance, ensuring compatibility with a wide range of network video recorders and third-party software.

With robust weatherproof and vandal-resistant ratings, particularly in models meant for outdoor use, the WV-CW504 series ensures reliable performance in various environmental conditions. The sleek design of these cameras also allows them to blend seamlessly into any interior or exterior space, enhancing security without compromising aesthetics.

In conclusion, the Panasonic WV-CW504FK, WV-CW504F, WV-CW504S, and WV-CW504SK network cameras offer a powerful combination of high-definition imaging, versatile installation options, and intelligent surveillance features, making them an excellent choice for ensuring the safety and security of any environment.