Fitting Instructions

Must be followed each time respirator is worn.

1.Cup the respirator in your hand, with the nosepiece at your fingertips, allowing the headbands to hang freely below your hand (Fig. 1).

2.Position the respirator under your chin with the nosepiece up. Pull the top strap over your head resting it high at the top back of your head. Pull the bottom strap over your head and position it around the neck below the ears (Fig. 2).

3. Place your fingertips from both hands at the top of the metal 4.

Perform a User Seal Check prior to each wearing. To check

nosepiece. Using two hands, mold the nose area to the

the respirator-to-face seal, place both hands completely over

shape of your nose by pushing inward while moving your

the respirator and inhale sharply. Be careful not to disturb

fingertips down both sides of the nosepiece (Fig. 3).

the position of the respirator. A negative pressure should be

WPinching the nosepiece using one hand may result feltin inside the respirator. If air leaks around nose, readjust the

improper fit and less effective respirator performance. Use

nosepiece as described in step 3. If air leaks at the respirator

two hands.

edges, work the straps back along the sides of your head.

 

If you CANNOT achieve a proper seal, DO NOT enter the

 

contaminated area. See your supervisor.

Removal Instructions

See step 2 of Fitting Instructions and cup respirator in hand to maintain position on face. Pull bottom strap over head. Still holding respirator in position, pull top strap over head and remove respirator.

NIOSH Approved: N95

At least 95% filtration efficiency against solid and liquid aerosols that do not contain oil.

3M

St. Paul, Minnesota, USA

1-800-243-4630

8511 Series Respirators

THESE RESPIRATORS ARE APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS:

 

 

RESPIRATOR COMPONENTS

 

 

 

 

 

 

 

FILTERING FACEPIECE

 

 

 

 

 

 

 

 

 

PROTECTION1

 

 

 

 

CAUTIONS AND

TC-

8211

8511

8515

8516

LIMITATIONS2

84A-1299

N95

X

X

X

X

ABCJMNOP

1. PROTECTION

N95 - Particulate Filter (95% filter efficiency level) effective against particulate aerosols free of oil; time use restrictions may apply.

2. CAUTIONS AND LIMITATIONS

A - Not for use in atmospheres containing less than 19.5 percent oxygen. B - Not for use in atmospheres immediately dangerous to life or health.

C - Do not exceed maximum use concentrations established by regulatory standards. J - Failure to properly use and maintain this product could result in injury or death.

M - All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA and other applicable regulations.

N - Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer.

O - Refer to User's Instructions, and/or maintenance manuals for information on use and maintenance of these respirators.

P - NIOSH does not evaluate respirators for use as surgical masks.

Rev. D: 03-27-08

This respirator contains no components made from natural rubber latex.

Image 5
Contents # 8511/8211/07185 98-0060-0125-33 34-8713-5011-1 3M 2014. All rights reservedUse Instructions Use For Do Not Use ForBiological Particles Storage Conditions and Shelf Life Use LimitationsTime Use Limitation United States, contactRemoval Instructions Fitting InstructionsRespirateur N95 contre les particules Particules biologiques Utiliser pour Ne pas utiliser pourDirectives d’utilisation Restrictions d’utilisationDurée maximale d’utilisation Conditions d’entreposage et durée de conservationDirectives d’ajustement Directives de retraitSt. Paul, Minnesota, É.-U 800 Respirateurs de série Homologation du Niosh N95Respirador para partículas N95 Partículas biológicas Usar para No usar paraInstrucciones Limitaciones de usoLimitación de tiempo de uso Condiciones de almacenamiento y vida útilHumedad relativa máxima de almacenamiento 80% HR En Estados Unidos Llame a 3M en su localidadInstrucciones de remoción Instrucciones de ajuste