Toshiba SL-9000 owner manual When entering PLU#, be careful of the following

Page 34

11. PROGRAMMING PROCEDURES

11.4 NUTRITION SETTING

A

Additional Information Area 26.

(099999 or 0.0999.9)

ENTER

Enter the

 

Enter the

 

 

vitamin A.

ENTER

Vitamin C.

ENTER

 

(0999)

 

(0999)

 

 

Enter the

 

Enter the

 

 

Calcium.

ENTER

Iron.

ENTER

 

(0999)

 

(0999)

 

 

e

 

 

 

 

 

 

Additional

 

ENTER

 

 

 

Information

 

 

 

 

 

 

 

 

PROG.

<MENU>

 

 

 

 

Page 1

 

 

 

 

 

 

 

 

 

ESC.

Main

 

 

 

 

<MENU>

 

 

 

 

 

 

 

 

 

f

 

 

 

 

 

Pressing the key instead of the ENTER key advances to the next menu.

Pressing the key

returns to the preceding menu.

NOTES: 1.

When entering PLU#, be careful of the following.

 

When a selected PLU# is not stored in the PLU file, an error occurs.

2.

Nutrition file is input each time the

ENTER

key is pressed. Thus, the if you quit

 

 

 

 

 

key is not

 

the procedure on the way, data entered without pressing

ENTER

stored.

3.The additional information can be used only when its title has been registered in Section 11.17.

11- 9

Image 34
Contents SL-9000/9000N-FFR-US/CA/QR Page Safety Summary Precautions Table of Contents 14.1 13.113.2 14.2Introduction Accessories Applicable ModelSpecification ScaleSTLAN-2P OptionLON TmccAppearance Label Guide Printer Cover Main Power SwitchAdjustable Legs Meat Platter Power Cord Level GaugeUS Type DisplayCA/QR Type Programming Keyboard KEY LayoutProgramming Keyboard Function Send SpaceProg Operation Keyboard Function Operation Keyboard and Speed KeyboardPLU DT/TM PRTFor VoidSelf Service Keyboard ZeroKEY Layout Procedure Before Operation Speed KEY SETInstallation Procedure Level Adjustment Removal and Replacement of Media Removal and Replacement of Media Power Outline of Operation1/4LB KEY 100g, kg KEY LB/kg KEY Registration modeXNOT Available Tmcc CMT-port communicarion Clerk LabelProgramming Procedures How to access to Programming MenuTitle and Contents of Programming Menu How to enter characters TEC StorePLU Data Edit MenuPLU Data Setting Set tare limitAuto Code Ingredient Message Nutrition Setting When entering PLU#, be careful of the following Daily Value Max digits Contents of Daily value Set the Daily Value TableDeleting Nutrition Data Memory file is sorted when a memory full error occursMemory file sort PLU Verifying Label Menu Item No Verifies PLU data stored in the scaleAddress and Commercial Message Setting Combination Message Message construction Message display timeThank YOU Call Scrolling Flashing Curtaining Scrolling up Scrolling downThank YOU Thank YOU ANK YOU Call AGASpecial Information Grade LineDepartment Number Speed KEY SettingSetting Department/Vendor Number Vendor NumberPrint Format By pressing KeyLabel Format Number Table Format NoMenu Item No DATE/TIME SettingCMT Operations Error code during PL-3 operation PL-3 OperationItem # Transmission Item ListCMT Transmission Delay Time Table IN-LINE/LOCALLON System Price Address SL-9000N only Cancel Retry ContinueData Transmission Initial #0 #19, SL-9000N only① Weigh or Fix Price Format Default Bar Code FormatBAR Code Format ② By Count FormatFlag PLU # UPC # PC/D Price Weight PLU # UPC # PC/DAdditional 233 Title No Format Additional 221Additional 231 232 Additional 234 235 Additional 7,8 238 Additional 9,10 239SL-9000N only Transferring Logo DataVerify SL-9000=CMT Idiom Setting Error message during data transmissionVendor Setting Key functions Free Format SettingEnter SP-INFO/NET WT Logo Frequent Shopper Print coordinate Programmed Data Verification Reports How to access Report menuMenu Set the zone PLU #. Ex. PLU #100 ~108 R S Password SecuritySetting Password and Protect Menu R S X Z× ー × Calling Menu by Entering Password Operating Procedures How to access REG., M.DOWN, or Rewrap menuMenu REG., M.DOWN, or Rewrap Mode Weigh Weighing OperationFIX Price Operation for US Type only By Count Operation For Print Count Operation To check the remaining number, clear the PLU and press KeyExample B When operating in Fix or By Count mode Set the number of labels. Max labels Enter the PLU # Issuing Labels with NET Weight Statement for US Type only PLUSample label 14-10 TARE/SAVE Function Procedures Calling and Printing Grade Lines Calling and Printing Logos LogoMenu REG, M.DOWN, or Rewrap Mode WEIGH, FIX, or by Count Selecting Print ItemDate Change Batch Print Mode with 30 Items Run Assignment Unit Price Change and G.Line/LOGO Call Key is pressed to issue Label Issue Stop or CancelTotals Overflow error occurs when KeyVisual Commodity Library Dpt #Floating Vendor Price deletion SubtotalHow to access Read or Reset menu Total OperationPLU Total Report Hourly Total ReportGrand Total Report Ex. Report MenuVendor Total Report For Enter PLU TotalError Message Table Programming ModeLabel lssue Mode Report and Reset ModeLON System Mode Cleaning the Print Head Troubleshooting Before You Call for Service