Toshiba SL-9000 owner manual Price deletion, Subtotal

Page 86

14. OPERATING PROCEDURES

14.13 FLOATING VENDOR

(2)Restraints in case of clerks’ name printing on labels

1)“GRADE LINE” can not be selected and printed.

2)Commodity name can not be printed on the 4th line of 57 mm eidth label and 2nd line of 48 mm width label, because 1 line of commodity is used for clerk’s name printing.

3)The printing position of clerk name will be selected by the initial setting for GRADE LINE position.

Initial 3-6 (G. Line Print Position)

0: Right side on bottom line of commodity name

1: Left side on bottom line of commodity name

If you would like to switch the initial setting # please contact your authorized TOSHIBA TEC representative.

Price deletion

Prices already registered can be deleted in the following procedure.

Enter vendor #.

Enter the deletion mode.

NEXT PLU: the next item

VOID: the previous item

Delete a registered price.

VOID

 

NEXT

or

VOID

 

PLU

 

 

 

 

 

 

 

*

Exit the deletion mode.

Subtotal

C

The following procedure will sum up all of the registered items.

Enter vendor #.

Press:

ST

 

Enter prices.

Press:

*

 

C

Press:

(Cancel)

A receipt will be issued.

14-21

Image 86
Contents SL-9000/9000N-FFR-US/CA/QR Page Safety Summary Precautions Table of Contents 14.1 13.113.2 14.2Introduction Accessories Applicable ModelSpecification ScaleSTLAN-2P OptionLON TmccAppearance Label Guide Printer Cover Main Power SwitchAdjustable Legs Meat Platter Power Cord Level GaugeCA/QR Type DisplayUS Type Programming Keyboard Function KEY LayoutProgramming Keyboard Prog SpaceSend PLU Operation Keyboard and Speed KeyboardOperation Keyboard Function DT/TM PRTFor VoidSelf Service Keyboard ZeroKEY Layout Procedure Before Operation Speed KEY SETInstallation Procedure Level Adjustment Removal and Replacement of Media Removal and Replacement of Media Power Outline of Operation1/4LB KEY 100g, kg KEY LB/kg KEY Registration modeXNOT Available Tmcc CMT-port communicarion Clerk LabelProgramming Procedures How to access to Programming MenuTitle and Contents of Programming Menu How to enter characters TEC StorePLU Data Edit MenuPLU Data Setting Set tare limitAuto Code Ingredient Message Nutrition Setting When entering PLU#, be careful of the following Daily Value Max digits Contents of Daily value Set the Daily Value TableMemory file sort Memory file is sorted when a memory full error occursDeleting Nutrition Data PLU Verifying Label Menu Item No Verifies PLU data stored in the scaleAddress and Commercial Message Setting Combination Message Message construction Message display timeThank YOU Call Scrolling Flashing Curtaining Scrolling up Scrolling downThank YOU Thank YOU ANK YOU Call AGASpecial Information Grade LineDepartment Number Speed KEY SettingSetting Department/Vendor Number Vendor NumberPrint Format By pressing KeyLabel Format Number Table Format NoCMT Operations DATE/TIME SettingMenu Item No Error code during PL-3 operation PL-3 OperationCMT Transmission Item ListItem # Transmission Delay Time Table IN-LINE/LOCALLON System Price Address SL-9000N only Cancel Retry ContinueData Transmission Initial #0 #19, SL-9000N only① Weigh or Fix Price Format Default Bar Code FormatBAR Code Format ② By Count FormatFlag PLU # UPC # PC/D Price Weight PLU # UPC # PC/DAdditional 233 Title No Format Additional 221Additional 231 232 Additional 234 235 Additional 7,8 238 Additional 9,10 239Verify SL-9000=CMT Transferring Logo DataSL-9000N only Idiom Setting Error message during data transmissionVendor Setting Enter Free Format SettingKey functions SP-INFO/NET WT Logo Frequent Shopper Print coordinate Menu How to access Report menuProgrammed Data Verification Reports Set the zone PLU #. Ex. PLU #100 ~108 R S Password SecuritySetting Password and Protect Menu R S X Z× ー × Calling Menu by Entering Password Operating Procedures How to access REG., M.DOWN, or Rewrap menuMenu REG., M.DOWN, or Rewrap Mode Weigh Weighing OperationFIX Price Operation for US Type only By Count Operation For Print Count Operation To check the remaining number, clear the PLU and press KeyExample B When operating in Fix or By Count mode Set the number of labels. Max labels Enter the PLU # Issuing Labels with NET Weight Statement for US Type only PLUSample label 14-10 TARE/SAVE Function Procedures Calling and Printing Grade Lines Calling and Printing Logos LogoMenu REG, M.DOWN, or Rewrap Mode WEIGH, FIX, or by Count Selecting Print ItemDate Change Batch Print Mode with 30 Items Run Assignment Unit Price Change and G.Line/LOGO Call Key is pressed to issue Label Issue Stop or CancelTotals Overflow error occurs when KeyVisual Commodity Library Dpt #Floating Vendor Price deletion SubtotalHow to access Read or Reset menu Total OperationPLU Total Report Hourly Total ReportGrand Total Report Ex. Report MenuVendor Total Report For Enter PLU TotalError Message Table Programming ModeLabel lssue Mode Report and Reset ModeLON System Mode Cleaning the Print Head Troubleshooting Before You Call for Service