Accel 3302 manual Initial Settings, Normal Operation

Page 23

OPERATION & MAINTENANCE

INITIAL SETTINGS

NORMAL OPERATION

Pressing the HEAT switch will illuminate both the green and yellow LEDs on the remote control unit. The green LED indicates that the fans (both dryer and exhaust fans if so equipped) are running while the yellow LED indicates that the dryer is armed and the heat will come on automatically when the press goes on impression. When the press does go on impression, the green LED will illuminate indicating that the heat is on. Pressing the heat button again will disarm the heat mode but the fans will continue to run. To turn the unit OFF press the FAN switch at any time.

FAN ONLY OPERATION

To operate only the fans, press the FAN switch. The green LED will illuminate and the fans will come on (both the dryer and exhaust fans if so equipped). The heat mode of the dryer is not armed and will not come on with impression. To turn the fans OFF press the FAN switch again.

FAN SPEED CONTROL

To adjust the fan to a higher setting, press the up arrow on the remote control unit. To decrease the fan speed press the down arrow on the remote. The fans will automatically go to the minimum speed setting for a few seconds when the press goes on impression and then they return to the previous setting. This reduction in fan speed allows the dryer to heat up more quickly.

Try running Tempest® with the fan speed at "4" with the switch on "HEAT." After about 1" of paper is stacked in the delivery, insert the thermometer into the center of the stack. Allow the thermometer to stabilize. It should be approximately 20o F above the initial pile temperature.

If the temperature is below that, decrease the fan speed slightly.

If the temperature is above that, increase the fan speed slightly.

23

Image 23
Contents Tempest Hot Air Drying System Technical General InformationInformation SafetyElectrical RequirementsHOT AIR VS Infrared What Makes Tempest Work HOW Drying is Accomplished with Tempest Page Installation Page Installation Page Installation Page Installation Page Installation Page Installation Page Installation Page Installation Operation HOW Tempest WorksTempest Normal Operation Initial SettingsFactors That Effect Drying MaintenanceSafety Requirements Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Indian Trail, Dallas, TX 75229 Phone 972-484-6808, Fax