Accel 3302 manual Installation

Page 15

INSTALLATION

10

11

12

Connect the two hoses together using the "Y" connector (left hand subject arrow). Connect the Tempest® Spray line to the press spray hopper line using the reducer (right hand subject arrow).

Attach the exhaust fan/manifold assembly to the center of the delivery guard as shown. Make sure that the arrow on the fan is pointing toward the guard (out of the press) and that the wires are routed toward the NOPS of the press. The top two screws go through the second slot down from the top of the guard. Make sure that the open end of the manifold is pointing toward the NOPS.You will need to file the openings in the guard so that the screws will pass through the guard.

Locate the 2 impression cylinder activation solenoids located on the OPS of the press, one under each head. Remove the 2 outside nuts and screws from each solenoid (lower subject arrows). Install the provided longer M4 x 16MM screws. Install the supplied switch assemblies (as shown in the picture) over the screws and secure them using the original hardware.

The left photo show the #1 head solenoid and the right shows the #2 head solenoid. Note how the microswitch trip arms extend up to the spring studs located on activation linkage (upper subject arrows).

15

Image 15
Contents Tempest Hot Air Drying System Technical General InformationInformation SafetyElectrical RequirementsHOT AIR VS Infrared What Makes Tempest Work HOW Drying is Accomplished with Tempest Page Installation Page Installation Page Installation Page Installation Page Installation Page Installation Page Installation Page Installation HOW Tempest Works TempestOperation Normal Operation Initial SettingsFactors That Effect Drying MaintenanceSafety Requirements Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Indian Trail, Dallas, TX 75229 Phone 972-484-6808, Fax