VXI Six-Slot VXIBus Chassis user manual Cooling Capacity for CT-100B Typical

Page 16

VXI Technology, Inc.

COOLING SPECIFICATIONS

COOLING REQUIREMENTS (TBD)

60 W/slot for a 10°C Rise

80 W/slot for a 15°C Rise

AIR FLOW PATH

Air is drawn into the chassis from the rear and is pressurized below the cards. The air is then distributed across all slots along the total length of each slot and is exhausted through the top of the mainframe. When the mainframe is rack mounted, allow approximately 2 inches (50 mm) of clearance at the top and rear for proper airflow.

 

2.5

 

 

 

 

O

2.0

 

 

 

 

2

 

 

 

 

- mm H

1.5

 

 

 

 

Drop

1.0

 

 

 

 

Pressure

 

 

 

 

0.5

 

 

 

 

 

 

 

 

 

 

0.0

 

 

 

 

 

0

2.0

4.0

6.0

8.0

 

 

 

Airflow - Liters/Sec

 

 

* Covers all slots, unrestricted

FIGURE 1.3 COOLING CAPACITY FOR CT-100B (TYPICAL)

16

CT-100B Introduction

Image 16
Contents CT-100B Series VXI Technology, Inc Table of Contents Warranty Limitation of WarrantyCertification Restricted Rights LegendC L a R a T I O N O F C O N F O R M I T Y EMCVXI Technology, Inc CT-100B Preface General Safety Instructions Terms and SymbolsSuspected. Product should be inspected or serviced Support Resources VXI Technology, Inc CT-100B Preface Introduction IntroductionBackplane General DescriptionPerformance Flexibility 2CT-100BSIX-SLOT Chassis Covers OFFCT-100B Series Specifications Mttr+5VSTBY Cooling Capacity for CT-100B Typical CT-100B Dimensional Diagram VXI Technology, Inc CT-100B Introduction Installation Line Voltage SelectionCT-100B Back Panel Rack Mount Option Installation OverviewRack Mount KIT Installation Parts ListAssembly Procedure Required ToolsRack Mount EAR Installation Diagram Rack Slide Installation 20 Assembly InstructionsRack Slide Installation Diagram Rack Mount Door KIT Installation Rack Door Installation Diagram Acrylic Rack Mount Door KIT Installation Acrylic Rack Door Installation Diagram VXI Technology, Inc CT-100B Installation 1CT-100BSIX-SLOT Chassis W/ Installed Instruments OperationFront Panel Voltage Indicators Index 5V Standby