VXI CT-100B, Six-Slot VXIBus Chassis user manual Rack Slide Installation 20, Assembly Instructions

Page 24

VXI Technology, Inc.

RACK SLIDE INSTALLATION (20” AND 24”)

The 20” and 24” slide hardware kits (Options 63 and 64, respectively) provide standard flanges to mount the slides into standard EIA relay racks. It should be noted that the slide flanges in the front should be installed behind the rack’s front panel mounting rails. This will allow the rack mounting ears to sit flush with the front of the rack. It should also be noted that although the hardware provided in this kit will provide all the necessary components to successfully install the CT-100B into a rack, there are many variations in how EIA relay racks are designed and additional adapter hardware may be required to install the chassis. Please refer to the relay rack manufacture’s catalog for additional options.

This procedure provides instructions for installing the 20” or 24” slide kits. Note that the 20” and 24” slide kits are identical except for the length of the slide units. A 20” slide kit is used when the chassis is flush mounted and a 24” slide kit is used when the chassis is recess mounted.

REQUIRED TOOLS

1.#2 Phillips Screwdriver

2.1/8" Flat Blade Screwdriver

PARTS LIST

QTY

ITEM

VTI P/N

2

Slide, Rack Mount, Steel, 20”

37-0054-020

 

- or -

 

2

Slide, Rack Mount, Steel, 24”

37-0054-024

1

Hardware Kit, Rack Mount Slide, Steel

37-0055-000

6

Screw, 8-32 x 3/8” Pan Head Phillips, Sems Zinc

37-0073-037

6

Screw, 8-32 x 1/4” Pan Head Phillips, Steel/Zinc

37-0074-025

4

Screw, 8-32 x 3/8”, F/H Undercut Phillips, Zinc

37-0115-037

2

Bracket, Slide, Front

41-0108-000

1

Bracket, Slide, Top Side

41-0131-000

1

Bracket, Slide, Bottom

41-0132-000

ASSEMBLY INSTRUCTIONS

1.Lay the chassis on a protected work surface on its long side with the voltage monitor LEDs of the chassis facing front with the power switch toward the top.

2.If the rack mount ears were installed flush, remove the rack mount ears and install the front slide bracket to them as shown in the assembly drawing using a flat head screw driver. If the rack mount ears were installed recessed, simply install the slide brackets onto the ears as shown on the following page.

3.Reinstall the rack mount ears (if necessary).

4.Install the top and bottom slide brackets using 1/4” Phillips pan head screws. Note that the slide mounting holes should be oriented below the centerline of the chassis.

24

CT-100B Installation

Image 24
Contents CT-100B Series VXI Technology, Inc Table of Contents Warranty Limitation of WarrantyCertification Restricted Rights LegendC L a R a T I O N O F C O N F O R M I T Y EMCVXI Technology, Inc CT-100B Preface General Safety Instructions Terms and SymbolsSuspected. Product should be inspected or serviced Support Resources VXI Technology, Inc CT-100B Preface Introduction IntroductionGeneral Description BackplanePerformance Flexibility 2CT-100BSIX-SLOT Chassis Covers OFFCT-100B Series Specifications Mttr+5VSTBY Cooling Capacity for CT-100B Typical CT-100B Dimensional Diagram VXI Technology, Inc CT-100B Introduction Installation Line Voltage SelectionCT-100B Back Panel Rack Mount Option Installation OverviewRack Mount KIT Installation Parts ListAssembly Procedure Required ToolsRack Mount EAR Installation Diagram Rack Slide Installation 20 Assembly InstructionsRack Slide Installation Diagram Rack Mount Door KIT Installation Rack Door Installation Diagram Acrylic Rack Mount Door KIT Installation Acrylic Rack Door Installation Diagram VXI Technology, Inc CT-100B Installation 1CT-100BSIX-SLOT Chassis W/ Installed Instruments OperationFront Panel Voltage Indicators Index 5V Standby