VXI CT-100B Rack Mount KIT Installation, Required Tools, Parts List, Assembly Procedure

Page 22

VXI Technology, Inc.

RACK MOUNT KIT INSTALLATION

The rack mount kit (Option 59) provides the basic hardware necessary to rack mount the CT-100B chassis. With the chassis being only 15” wide, standard rack support rails cannot provide mechanical support to the chassis. If the equipment mounted below the CT-100B cannot provide mechanical support to the chassis, either 20” or 24” rack slides will be required to support the chassis when installed into the rack. The rack mounting ears are designed to allow the chassis to be flush mounted in the rack or recessed 4”.

REQUIRED TOOLS

1.#2 Phillips Screwdriver

PARTS LIST

QTY

ITEM

VTI P/N

4

Screw, 6-32 x 1/2", Phillips/Sems

37-0028-050

1

Bracket, Rack Flange w/ hinge mounting holes

41-0135-000

1

Bracket, Rack Flange

41-0135-001

ASSEMBLY PROCEDURE

1.Remove the four (4) black plastic feet from the bottom of the chassis.

2.Lay the chassis on a protected work surface on its long side with the voltage monitor LEDs of the chassis facing front with the power switch toward the top.

3.Locate and remove four black plastic feet on the side of the chassis and four black plastic feet on the bottom of the chassis. Retain the feet if restoring the chassis to its original portable use is anticipated.

4.Find two threaded holes on each side of the chassis (the plastic feet were attached to two of these holes) towards the front of the unit.

5.Line up the rack mount ears with the threaded holes selecting the flush or recessed position as desired. Refer to the rack mount ear installation diagram for visual assistance.

6.Secure the rack ears using the supplied #8-32 hardware.

Before installing the chassis into an EIA switch rack, the chassis handle should be removed. This can be done by doing the following:

1.Remove the four screws located near the handle.

2.Remove the two black decorative covers at each end of the carrying handle using the flat blade screwdriver. Place a piece of paper under the screwdriver blade to prevent scratching the chassis cover.

3.Remove the four Phillips screws holding the handle in place and then remove the handle itself. Retain the carrying handle components if there may be some need to restore the chassis to its original portable use in the future.

22

CT-100B Installation

Image 22
Contents CT-100B Series VXI Technology, Inc Table of Contents Certification WarrantyLimitation of Warranty Restricted Rights LegendC L a R a T I O N O F C O N F O R M I T Y EMCVXI Technology, Inc CT-100B Preface General Safety Instructions Terms and SymbolsSuspected. Product should be inspected or serviced Support Resources VXI Technology, Inc CT-100B Preface Introduction IntroductionBackplane General DescriptionPerformance Flexibility 2CT-100BSIX-SLOT Chassis Covers OFFCT-100B Series Specifications Mttr+5VSTBY Cooling Capacity for CT-100B Typical CT-100B Dimensional Diagram VXI Technology, Inc CT-100B Introduction Installation Line Voltage SelectionCT-100B Back Panel Rack Mount Option Installation OverviewAssembly Procedure Rack Mount KIT InstallationParts List Required ToolsRack Mount EAR Installation Diagram Rack Slide Installation 20 Assembly InstructionsRack Slide Installation Diagram Rack Mount Door KIT Installation Rack Door Installation Diagram Acrylic Rack Mount Door KIT Installation Acrylic Rack Door Installation Diagram VXI Technology, Inc CT-100B Installation 1CT-100BSIX-SLOT Chassis W/ Installed Instruments OperationFront Panel Voltage Indicators Index 5V Standby