VXI CT-100B, Six-Slot VXIBus Chassis user manual Acrylic Rack Mount Door KIT Installation

Page 28

VXI Technology, Inc.

ACRYLIC RACK MOUNT DOOR KIT INSTALLATION

An acrylic rack mount door is offered as an alternative to the aluminum rack mount door. The kit (Option 65) provides the necessary hardware to install a 1/8” thick acrylic door in front of the rack mounted chassis. An installation diagram is provided on the following page for ease of assembly. This option requires that the rack mount ear kit also be installed and configured for recessed mounting.

REQUIRED TOOLS

1.#2 Phillips Screwdriver

2.1/8" Flat Blade Screwdriver

3.11/32" Open Ended Wrench

PARTS LIST

QTY

ITEM

VTI P/N

2

Screw, 6-32 x 1/2" Pan Head Phillips, Sems Zinc

37-0028-050

2

Nut, Hex, 6-32, Zinc/Steel

37-0030-632

1

Latch, Vise Action, Knob Style, Black

37-0065-000

2

Hinge, Adjustable Damping, Black

37-0066-000

4

Screw, 8-32 x 3/8" Pan Head Phillips, Black Oxide

37-0079-037

1

Stop, Front Door, CT-100B

41-0133-000

1

Door, Front, CT-100, Acrylic

41-0303-000

2

Brace, Rackmount, CT-100B

41-0136-000

4

Nut, Hex, 8-32, Zinc/Steel

37-0030-832

4

Washer, Split Lock, 8-32 Zinc

37-0013-008

4

Washer, Flat 8-32, Zinc

37-0012-008

4

Screw, 8-32 x 1/2" Pan Head Phillips, Black Oxide

37-0079-050

4

Screw, 8-32 x 3/8" Flat Head Phillips, Zinc

37-0080-037

ASSEMBLY PROCEDURE

1.Lay the chassis on a protected work surface on its long side with the voltage monitor LEDs of the chassis facing front with the power switch toward the top.

2.Locate two rack mount (cross) braces. Install one each along the front of the flanges (one on top and one on the bottom) using four (two ea.) #8 flathead screws. The lip along the long edge of each brace goes toward the front and pointing inside. The braces fit over the flanges and the screws are placed from the inside going through the flange and then into the brace.

3.Locate the front door and two hinges. Install the two hinges to the front door using four 1/2” black oxide pan head screws through the holes of the hinge with the flat washer in contact with the door and with the split lock washer between the hex nut and the flat washer.

4.Locate the latch kit and install it into the door from the side where the hinges are mounted.

5.Locate the door latch bracket and install it on the rack mount ear opposite the end where the hinges will be installed. Use the rack mount door installation diagram below as a reference.

28

CT-100B Installation

Image 28
Contents CT-100B Series VXI Technology, Inc Table of Contents Warranty Limitation of WarrantyCertification Restricted Rights LegendC L a R a T I O N O F C O N F O R M I T Y EMCVXI Technology, Inc CT-100B Preface General Safety Instructions Terms and SymbolsSuspected. Product should be inspected or serviced Support Resources VXI Technology, Inc CT-100B Preface Introduction IntroductionBackplane General DescriptionPerformance Flexibility 2CT-100BSIX-SLOT Chassis Covers OFFCT-100B Series Specifications Mttr+5VSTBY Cooling Capacity for CT-100B Typical CT-100B Dimensional Diagram VXI Technology, Inc CT-100B Introduction Installation Line Voltage SelectionCT-100B Back Panel Rack Mount Option Installation OverviewRack Mount KIT Installation Parts ListAssembly Procedure Required ToolsRack Mount EAR Installation Diagram Rack Slide Installation 20 Assembly InstructionsRack Slide Installation Diagram Rack Mount Door KIT Installation Rack Door Installation Diagram Acrylic Rack Mount Door KIT Installation Acrylic Rack Door Installation Diagram VXI Technology, Inc CT-100B Installation 1CT-100BSIX-SLOT Chassis W/ Installed Instruments OperationFront Panel Voltage Indicators Index 5V Standby