SINGLE PHASE INSTALLATION

IMPORTANT: The jointer cutterhead is a high inertia load which causes the motor to draw a high inrush current during starting. The jointer must be connected to an electrical circuit protected by a properly sized fuse or circuit breaker to handle this high inrush of current. We recommend either a 30 Amp time lag fuse, or a 40 Amp motor start circuit breaker.

If your machine is supplied with single phase electricals, proceed as follows when connecting your machine to an electrical power system:

1. Remove screw (A) Fig. 12, and terminal strip cover (B).

2.Remove plastic covering (C) Fig. 13, that snaps into terminal strip.

3.Bring power line through access hole in bottom of terminal strip box and connect the two power lines to terminals (D) Fig. 14, and the green ground wire to ground screw (E).

4.Replace plastic covering (C) Fig. 13, and terminal strip cover removed in STEP 1.

B

A

Fig. 12

C

D

E

Fig. 13

Fig. 14

11

Page 11
Image 11
DeWalt 37-360 instruction manual Single Phase Installation