RAMP INSTALLATION
Electrical Connections
An
The ramp installer provides an ap- propriate momentary contact control switch.
Terminate the power supply, ground, ramp OUT signal and ramp IN signal DVVSHFLÀHGLQOHJHQG
The Positive (+) “battery” lead wire
must be protected by an
WARNING
Positive (+) battery lead wire must be protected by
Failure to do so may result in serious bodily injury and/or property damage.
BF3248Y & BF3748Y
CONNECTOR - P1
(B.C.# 30136)
E D C
A B
F G H
WIRING PROVIDED
BY INSTALLER
OR
8-COND WIRE CODE
PIN | COLOR |
APOWER SOURCE - 12 GA.*
B VEHICLE GROUND - 12 GA.*
C TO USER STOW - 16 GA.*
D TO USER DEPLOY - 16 GA.*
EPLUG - NOT USED
FPLUG - NOT USED
GRAMP STOW SIGNAL - 16 GA.* H RAMP DEPLOY SIGNAL - 16 GA.*
* RECOMMENDED WIRE GAUGE
BF3248YP
CONNECTOR - P1
(B.C.# 30136)
E D C
A B
F G H
WIRING PROVIDED
BY INSTALLER
PIN | COLOR |
APOWER SOURCE - 12 GA.*
B VEHICLE GROUND - 12 GA.*
C TO USER STOW - 16 GA.*
D TO USER DEPLOY - 16 GA.*
EPLUG - NOT USED
FUSER IGN/MAN REL. - 16 GA.*
G RAMP STOW SIGNAL - 16 GA.* H RAMP DEPLOY SIGNAL - 16GA.*
* RECOMMENDED WIRE GAUGE
Male Plug
(supplied with ramp)
Connector
(ramp equipped)
Figure K
Electrical Connections Illustration