RAMP INSTALLATION

Electrical Connections

An 8-pin Deutsch connector (male plug) is supplied with the ramp.

The ramp installer provides an ap- propriate momentary contact control switch.

Terminate the power supply, ground, ramp OUT signal and ramp IN signal DVVSHFLÀHGLQOHJHQG

The Positive (+) “battery” lead wire

must be protected by an in-line 30 ampere fuse or circuit breaker (installer provided).

WARNING

Positive (+) battery lead wire must be protected by installer-provided 30 ampere fuse or circuit breaker.

Failure to do so may result in serious bodily injury and/or property damage.

BF3248Y & BF3748Y

CONNECTOR - P1

(B.C.# 30136)

E D C

A B

F G H

WIRING PROVIDED

BY INSTALLER

OR

8-COND WIRE CODE

PIN

COLOR

APOWER SOURCE - 12 GA.*

B VEHICLE GROUND - 12 GA.*

C TO USER STOW - 16 GA.*

D TO USER DEPLOY - 16 GA.*

EPLUG - NOT USED

FPLUG - NOT USED

GRAMP STOW SIGNAL - 16 GA.* H RAMP DEPLOY SIGNAL - 16 GA.*

* RECOMMENDED WIRE GAUGE

BF3248YP

CONNECTOR - P1

(B.C.# 30136)

E D C

A B

F G H

WIRING PROVIDED

BY INSTALLER

8-COND WIRE CODE

PIN

COLOR

APOWER SOURCE - 12 GA.*

B VEHICLE GROUND - 12 GA.*

C TO USER STOW - 16 GA.*

D TO USER DEPLOY - 16 GA.*

EPLUG - NOT USED

FUSER IGN/MAN REL. - 16 GA.*

G RAMP STOW SIGNAL - 16 GA.* H RAMP DEPLOY SIGNAL - 16GA.*

* RECOMMENDED WIRE GAUGE

8-pin Deutsch

Male Plug

(supplied with ramp)

8-pin Deutsch

Connector

(ramp equipped)

Figure K

Electrical Connections Illustration

Page 19

Image 21
Contents Braun Congratulations Contents Ramp Terminology Illustration Ramp TerminologyLeftin Outright Ramp Components Terminology IllustrationIntroduction Ramp Actions and Functions Ramp ComponentsSafety Symbols Safety FIRST! Know That Ramp Operation Safety PrecautionsRamp Operation Ramp Operation Pre-Operation Notes and Details Ramp Access Doors and InterlocksPreventive Maintenance Operation Procedure ReviewKeep clear of area in which ramp operates Ramp Passenger Safety All ramp safety precautionsRamp Manual Operation Ramp also. Read and become familiar withBodily injury and/or property damage Installation / Service Safety Precautions Ramp InstallationInstallation/Service Safety Precautions Installation RequirementsChassis Requirements Outboard Support Tube Recom Floor Pocket Clear Opening DimensionsÝ Structure Minimum 1-1/2 x 2 steel tub- ing or equivalentFigure E Clear Door Opening Width DimensionInstalled Ramp Deployed Installed Ramp StowedElectrical Connections Figure JElectrical Connections Illustration Electrical ConnectionsLO Light Oil Lubrication DiagramDE Door-Ease LG Light GreaseCycles Maintenance and Lubrication IntroductionYear 1250 Cycles Ramp deployed fully. Fill to within YearElectrical Systems DescriptionsFigure L Relief Valve Adjustment Procedure HydraulicsDeploy and Stow Pressure Relief Valves Drift in Speed Cam Drift OUT Speed CamTroubleshooting Diagnosis Chart TroubleshootingFaulty or Stow Blank for Layout Power Connections / Control Signals Provided by Installer Electrical Schematic BF3248Y & BF3748YWiring Diagram BF3248Y & BF3748Y Description Symbol Electrical Schematic BF3248YPRelay #2 Wire Code Wiring Diagram BF3248YPHydraulics Hydraulic Schematic BF3248Y & BF3748YQty Description BF3248Y BF3748Y Hydraulic Diagram and Parts List BF3248Y and BF3748YHydraulic Schematic BF3248YP Qty Description BF3248YP Hydraulic Diagram and Parts List BF3248YPItem Qty Description BF3248Y BF3748Y BF3248YP Repair PartsExploded View Specification and Dimensions Pre-Trip Inspection Daily Preventive Maintenance SchedProviding Access to the World Braun Commercial RA300 Transit Ramp