Braun RA300 service manual Systems Descriptions, Electrical

Page 26

SYSTEMS DESCRIPTIONS

Electrical

WARNING

Improper microswitch adjustment may re- sult in serious bodily injury and/or property damage.

Microswitches: Three micro- switches (limit switches) are incorporated in the RA300 Ramp electrical system. "Y" ramp mod- els microswitches are: Drift-In,Drift-Out and Counter. The "YP" ramp model also has three micro- switches: Drift-In,Drift-Out and

Power Down Activation. Details and photos of the microswitches DUHSURYLGHGEHORZ$GMXVW microswitch(es) as detailed (if necessary only).

Microswitch Sequence

Stowed Position: When the ramp is in the stowed posi- tion, the Drift-Out and Counter microswitches are deactivated (common and normally closed terminals have continuity). In contrast, the Drift-In microswitch is activated.

Deploy Sequence: When the ramp is in the stowed position, the Drift-Out microswitch is deacti- vated. Current is allowed to pass from the vehicle Deploy Relay, which directs current to the Bidi- rectional Pump motor in direction A (hydraulically drives cylinders to deploy ramp).

When the ramp’s platform reach- es the Drift-In limit (approx. 45° above ground level), the micro- switch is activated (common and normally open terminals have continuity), and the current to the Deploy Relay is interrupted thus stopping the current to the pump motor. The platform then “drifts”

downward to ground level, during which, at some position, the Drift- Out microswitch is activated. The Drift-In microswitch is deactivated during the deploy movement of the platform. Note, however, that neither of the other 2 micro- switches have any bearing on the deploy sequence.

Deployed Position: When the ramp is in the deployed posi- tion, the Drift-Out and Counter microswitches are activated. In contrast, the Drift-In microswitch is deactivated.

Stow Sequence: When the ramp is in the deployed posi- tion, the Drift-In microswitch is deactivated, allowing current to pass from the vehicle Stow switch circuit and energize the ramp Stow Relay, which directs current to the Bidirectional Pump motor in direction B (hydraulically drives cylinder to stow ramp).

When the ramp’s platform reach- es the Drift-Out limit (approx. 45° above ground level) and deacti- vates the microswitch, the current to the Stow Relay will be inter- rupted.

"Y" Models Only: When the ramp’s platform reaches the Drift-In limit (approx. 15° above YHKLFOHÁRRUOHYHO WKHPLFUR- switch is activated and the current to the Stow Relay is interrupted thus stopping the current to the pump motor. The platform then “drifts” downward to the vehicle ÁRRU7KH'ULIW2XWPLFURVZLWFKLV also deactivated during the stow movement of the platform

Page 24

Image 26
Contents Braun Congratulations Contents Ramp Terminology Ramp Terminology IllustrationRamp Components Terminology Illustration Leftin OutrightIntroduction Ramp Components Ramp Actions and FunctionsRamp Operation Safety Symbols Safety FIRST! Know ThatRamp Operation Safety Precautions Ramp Operation Ramp Access Doors and Interlocks Pre-Operation Notes and DetailsOperation Procedure Review Preventive MaintenanceKeep clear of area in which ramp operates Ramp Manual Operation All ramp safety precautionsRamp Passenger Safety Ramp also. Read and become familiar withBodily injury and/or property damage Ramp Installation Installation / Service Safety PrecautionsChassis Requirements Installation/Service Safety PrecautionsInstallation Requirements Ý Floor Pocket Clear Opening DimensionsOutboard Support Tube Recom Structure Minimum 1-1/2 x 2 steel tub- ing or equivalentClear Door Opening Width Dimension Figure EInstalled Ramp Stowed Installed Ramp DeployedFigure J Electrical ConnectionsElectrical Connections Electrical Connections IllustrationDE Door-Ease Lubrication DiagramLO Light Oil LG Light GreaseMaintenance and Lubrication Introduction CyclesYear 1250 Cycles Year Ramp deployed fully. Fill to withinSystems Descriptions ElectricalFigure L Deploy and Stow Pressure Relief Valves Relief Valve Adjustment ProcedureHydraulics Drift OUT Speed Cam Drift in Speed CamTroubleshooting Troubleshooting Diagnosis ChartFaulty or Stow Blank for Layout Electrical Schematic BF3248Y & BF3748Y Power Connections / Control Signals Provided by InstallerWiring Diagram BF3248Y & BF3748Y Electrical Schematic BF3248YP Description SymbolWiring Diagram BF3248YP Relay #2 Wire CodeHydraulic Schematic BF3248Y & BF3748Y HydraulicsHydraulic Diagram and Parts List BF3248Y and BF3748Y Qty Description BF3248Y BF3748YHydraulic Schematic BF3248YP Hydraulic Diagram and Parts List BF3248YP Qty Description BF3248YPRepair Parts Item Qty Description BF3248Y BF3748Y BF3248YPExploded View Specification and Dimensions Daily Preventive Maintenance Sched Pre-Trip InspectionProviding Access to the World Braun Commercial RA300 Transit Ramp