Fluke User Manual for Auto-Monitor Alarm Feature of Thermometers

Page 30

VT02, VT04A, VT04

Users Manual

Auto-Monitor Alarm (VT04A, VT04)

The Auto-Monitor Alarm feature is similar to the high/low temperature alarm feature. The difference is that instead of a flashing warning, the Product saves an image. When the temperature of an object in the scene goes above or below the threshold value, the Product saves the image.

By default, the file name for these captured images includes an A, for example, XXXA.is2.

Note

Measurements are the scene temperature (area shown inside the markers).

To set the Auto-Monitor Alarm:

(-10 °C to +250 °C)

(15 min, 30 min,

1 hr, 2 hr, 4 hr, 8 hr)

To stop the Auto-Monitor Alarm:

Note

The Auto Off feature is disabled in the Auto-Monitor Alarm mode.

The Auto-Monitor Alarm feature is disabled when the Product is connected to power.

22

Image 30
Contents VT02, VT04A, VT04 Limited Warranty and Limitation of Liability Table of Contents VT02, VT04A, VT04 List of Tables VT02, VT04A, VT04 List of Figures VT02, VT04A, VT04 Introduction How to Contact Fluke Safety InformationVisual IR Thermometer Before You Start VT04APower On and Off Start-Up Screen and Status IndicatorRechargeable Battery Rechargeable BatteryFeatures and Controls Button Operation Image BlendingVisual Image Alignment Control Visual Image AlignmentCapture and Save Micro SD Memory Card Warning IconsMenu Functions Basic NavigationParameter Adjustment Menu Icons Description VT02 Review Memory EmissivityTemperature Measurement  WarningTemperature Measurement Accuracy On-Screen Comparison of DS Ratio Reflected Background Temperature Color PaletteHot and Cold Markers Temperature Units Date and TimeHigh/Low Temperature Alarm VT04A, VT04 High/Low Temperature AlarmTime-Lapse Image Capture VT04A, VT04 To set the time-lapseAuto-Monitor Alarm VT04A, VT04 To stop the Auto-Monitor AlarmImage Capture Scenarios for Auto-Monitor Alarm LCD Brightness VT04A, VT04 Factory Reset VT04A, VT04Auto Off VT04A, VT04 BMP File Format VT04A, VT04Measurements Smartview SoftwareMaintenance How to CleanBattery Care   CautionVT02, VT04A Specifications VT04Image Presentation Controls and Adjustments Batteries