Introduction

The VT Series (the Product) are Visual IR Thermometers that combine a center-point temperature measurement with a blended digital image and heat map overlay. The thermal image removes the time necessary for component- by-component measurement associated with a traditional spot thermometer (radiometer). The Product is ideal for electrical, HVAC, and facility maintenance applications.

The recommended use model is:

1.Scan a broad area with the blended digital image and heat map overlay to quickly identify temperature anomalies that need more inspection.

2.Use the wide field-of-view to move closer to the target for a temperature measurement with more detail.

3.Capture both heat map and visual images with a single trigger pull.

4.Create a report with Fluke SmartViewsoftware.

The Product is easy to use. Turn on and within seconds it provides an image with no training needed. Several features increase the accuracy and usability of the Product:

Adjustable emissivity and reflected background compensation improves measurement accuracy on semi-reflective surfaces

Hot and cold spot temperature markers that guide the user to the hottest and coldest regions in the infrared heat map

Selectable color palettes

Visual/heat map image alignment

The VT04A and VT04 include these additional features:

High/Low Temperature Alarms

Time-Lapse Image Capture

Auto-Monitor Alarm

1

Image 9
Contents VT02, VT04A, VT04 Limited Warranty and Limitation of Liability Table of Contents VT02, VT04A, VT04 List of Tables VT02, VT04A, VT04 List of Figures VT02, VT04A, VT04 Introduction Safety Information How to Contact FlukeVisual IR Thermometer VT04A Before You StartStart-Up Screen and Status Indicator Power On and OffRechargeable Battery Rechargeable BatteryFeatures and Controls Image Blending Button OperationVisual Image Alignment Visual Image Alignment ControlMicro SD Memory Card Warning Icons Capture and SaveBasic Navigation Menu FunctionsParameter Adjustment Menu Icons Description VT02 Emissivity Review Memory Warning Temperature MeasurementTemperature Measurement Accuracy On-Screen Comparison of DS Ratio Reflected Background Temperature Color PaletteHot and Cold Markers Date and Time Temperature UnitsHigh/Low Temperature Alarm High/Low Temperature Alarm VT04A, VT04To set the time-lapse Time-Lapse Image Capture VT04A, VT04To stop the Auto-Monitor Alarm Auto-Monitor Alarm VT04A, VT04Image Capture Scenarios for Auto-Monitor Alarm Auto Off VT04A, VT04 Factory Reset VT04A, VT04LCD Brightness VT04A, VT04 BMP File Format VT04A, VT04Smartview Software MeasurementsHow to Clean Maintenance  Caution Battery CareVT02, VT04A VT04 SpecificationsImage Presentation Controls and Adjustments Batteries