RayTek FA, FR operating instructions Table of Contents

Page 5

 

TABLE OF CONTENTS

 

1 SAFETY INSTRUCTIONS

1

2 PRODUCT DESCRIPTION

2

2.1 THEORY OF OPERATION FOR 2‐COLOR SENSORS

2

2.1.1 Partially Obscured Targets

3

2.1.2 Targets Smaller Than Field of View

3

2.1.3 Low or Changing Emissivities

3

3 TECHNICAL DATA

4

3.1 MEASUREMENT SPECIFICATIONS

4

3.1.1 FA Models

4

3.1.2 FR Models

4

3.2

GENERAL SPECIFICATIONS

5

3.3

ELECTRICAL SPECIFICATIONS

6

3.4

DIMENSIONS

7

3.5

OPTICAL SPECIFICATIONS

9

3.5.1 FA Models

9

 

3.5.1.1 Standard Focus

9

 

3.5.1.2 Close Focus

10

3.5.2 FR Models

11

 

3.5.2.1 Standard Focus

11

 

3.5.2.2 Close Focus

12

3.6 SCOPE OF DELIVERY

12

4 SENSOR LOCATION

13

4.1 AMBIENT TEMPERATURE

13

4.2 ATMOSPHERIC QUALITY

13

4.3

ELECTRICAL INTERFERENCE

13

4.4 DISTANCE TO OBJECT

13

4.5 SENSOR PLACEMENT (1‐COLOR MODE)

14

4.6 SENSOR PLACEMENT (2‐COLOR MODE)

14

4.7 VIEWING ANGLES

15

5 INSTALLATION

17

5.1 MOUNTING THE SENSOR

17

5.2

AIMING

18

5.3 FIBER OPTIC CABLE

18

5.4

INSTALLING THE ELECTRONICS HOUSING

19

5.5

POWER SUPPLY

21

5.6

RS232/485 INTERFACE CONVERTER

21

5.7 CONNECTING TO A PC

21

5.7.1 Multidrop Installation (4‐Wire)

22

5.7.2 Multidrop Installation (2‐Wire)

22

5.7.3 Connecting to Terminal Block

23

5.8 INSTALLING OF MULTIPLE SENSORS IN A NETWORK

24

5.8.1 Wiring

24

5.8.2 Addressing

24

Image 5
Contents Marathon FA/FR Series Page Contacts Fluke Service CenterWorldwide Headquarters European Headquarters France United KingdomWarranty Table of Contents Milliamp Output Relay Outputs Trigger Fiber Calibration Page Marathon Series FA/FR Safety InstructionsSafety Instructions Product Description Product DescriptionTheory of Operation for 2‐Color Sensors ModelsLow or Changing Emissivities Partially Obscured TargetsTargets Smaller Than Field of View Technical Data Technical DataMeasurement Specifications FA ModelsGeneral Specifications Electrical Specifications Dimensions of Optical HeadFA Models DimensionsAdjustable Mounting Bracket for Optical Head Standard Focus Optical SpecificationsClose Focus Close Focus Spot Size Charts for FA modelsStandard Focus Spot Size Charts for FR models Scope of Delivery Close Focus Spot Size Charts for FR modelsSensor Location Sensor LocationSensor Placement 2‐Color Mode Sensor Placement 1‐Color ModeViewing Angles Sensor Placement in 2‐Color ModeAcceptable Sensor Viewing Angles Mounting the Sensor InstallationInstallation Fiber Optic Cable AimingConfiguring the Sensor Cable Installing the Electronics HousingRemoving the Terminal Block RS232/485 Interface Converter Power SupplyConnecting to a PC Multidrop Installation 2‐Wire Multidrop Installation 4‐WireWiring for 2‐Wire Sensor Setup Connecting to Terminal BlockAddressing Installing of Multiple Sensors in a NetworkWiring Control Panel OperationOperation Operation Modes Mode Selector Button Sequence FA ModelsSlope 2‐Color Temperature DisplayEmissivity 1‐Color Averaging AVG 4 2C/1C SwitchPeak Hold PKH Overview to Hold Functions Valley Hold VALHold Functions SetpointsDeadband Inputs and Outputs Ambient Background Temperature Compensation FA ModelsMilliamp Output Relay OutputsFactory Defaults Factory DefaultsOptions Cooling Platform for Electronics HousingOptions Accessories AccessoriesAccessories selection OverviewProtection Tube Air Purge CollarFlexible Fitting System Fitting SystemAvailable RS232/485 Interface Converters Order number ModelDimension of Industrial Power Supply Industrial Power SupplyProgramming Guide Command StructureProgramming Guide Remote versus Manual ConsiderationsTransfer Modes Poll ModeBurst Mode = + n ⋅15000 Response Time in Setup ModeCommand List Command ListXUFR1A Command Examples Command ExamplesMaintenance MaintenanceTroubleshooting Minor Problems TroubleshootingFail‐Safe Operation Error Codes in 1‐Color Mode FA modelsError Codes in 2‐Color Mode FR models Examples of failsafe conditions Current Output Values in accordance to an ErrorCleaning the Lens Removing the Fiber Optic Cable from the Optical Head Replacing the Fiber Optic CableRemoving the Fiber Optic Cable Put cable out Attaching the Fiber Optic Cable to the Optical Head Mounting the Fiber Optic CableFiber Calibration Dialog for the Calibration of the Fiber Cable Appendix AppendixDetermination of Emissivity Typical Emissivity ValuesTypical Emissivity Values Non‐Metals Marathon Series FA/FR55Typical Emissivity Values Metals Typical Slopes How to determine slope?Typical Percentage of Allowed Signal Reduction FR1A Models Signal Reduction FR ModelsAttenuation Influence on Accuracy Maximum ErrorInstrument Calibration Marathon