Sanyo 550 instruction manual Appendix 1 Part Numbers

Page 23

APPENDIX 1 PART NUMBERS

Part numbers will be provided separately

Note: some of the parts may not apply to your cabinet

FAN MOTOR

 

BUNG

66mm diameter

BUNG

100 diameter

ELEMENT

v.p.g. heater

ELEMENT

cabinet heater (primary)

ELEMENT

cabinet heater (secondary, if fitted)

MCB

MCB

MCB

MCB

RELAY

Delay

RELAY

Solid state (2.5 amps)

RELAY

Solid state (25 amps)

FILTER

Distilled water

SERVICE KIT

For air compressor

SOLENOID VALVE

Distilled water system

SENSOR

R.T.

WICK

For wet bulb, controller

WICK

For wet bulb, recorder

SAFETY THERMOSTAT

Mechanical

22

Image 23 Contents
Customer De Ronde Programming system Sanyo GallenkampEnvironmental Chamber Contents Part ONE the Cabinet Commissioning U.K. Customers only Health & Safety at WorkSanyo Gallenkamp service & maintenance facilities IntroductionCabinet Data Specification PhysicalFalse roof Exterior/finishInsulation ShelfCF1 Specification PerformanceOptional Facilities Digital Channel Cooling Auxiliary Format 550 Digital ChannelsDigital Channel Cooling Main System ChannelUser Programmable Channel Digital Channel 8 Voltage Free Terminal VFTPrinciple and Airflow DESCRIPTI0NRefrigeration unit control Temperature ControlHeating CoolingRelative Humidity Control Vapour phase generationRelative Humidity RH Relative Humidity DeterminationRelative Humidity Decrease Cabinets not requiring on-site commissioning InstallationAccessories & Spares PositioningInstrument compartment Drain Ambient TemperaturePower Supply Mains Interrupt BridgeEither Distilled Water SupplyWetwicks Test Load ProtectionVent 13. RS232 ConnectorSafety Thermostat Cable PortMains INDICATORS/PUSHBUTTONSReset Amber pushbutton Control Panel Instrumentation To Shut Down the Cabinet Normal Sequence Cabinet and Program Start UP Cabinet and Program Shut Down To Start the CabinetMonth Maintenance and CareMaintenance Schedule Weekly or between testsInspection and replacement of the wet wicks Maintenance MethodsInterior and exterior cleaning Cleaning of cabinet drainsDistilled water filter Check safety thermostatClean the refrigeration condenser LubricationAppendix 1 Part Numbers Operation InstallationMaintenance Appendix 2 REC/W Water SystemSystem draining Deioniser replacementPart 2 Format 550 Instructions ContentsFormat digital channels Introduction to FormatHow to use these instructions Menu system Getting startedFunction keys Using the on-line helpUsing the data entry windows Types of data entry field Status barPage General Operating Sequence Steady State Mode Condition settingCondition monitoring Resetting steady state setpointsEnding manual control Main Menu General Operating Sequence Entering a NEW ProgramGeneral Operating Sequence Running a Program Condition C %RH Status LoggingWriting a Program How to use Format programming sheetsEntering the data into the programmer Selecting digital channels when you know bestLoading and saving programs Log Running a programHolding a program Program Monitor WindowView program graph Program completionProgram deletion Log Introduction to Data LoggingStarting Data Logging Loading into Spreadsheets Stopping Data LoggingDisplaying Results Setting Alarms Introduction to AlarmsPage Host PC System Requirements C0MPUTER InterfacingIntroduction Computer InteractiveSetting UP OFF-LINE Chamber Intelligence InstallationInstalling the Security KEY Configuring the Host SoftwareSteady State Control Network Monitoring ModeMain Menu Printouts ProgramLogging Program Communications Frame Definition Computer interactive interfacing main protocolPhysical Layer Definition Serial Number Length HeaderPacket Count Data Block Compatibility with RS485 Multi-Controller ConfigurationData Block Length Serial NumberFunctional Layer Definition Controller Configuration RequestController Configuration Packet Flow SummaryStatus Request 129Page Open File for Reading Read Data Close FileWrite Block to File Open File for WritingSET/CHANGE Steady State Condition SET Controller to Remote Access ModeSET Controller to Local Access Mode Digital Channel Description ENABLE/DISABLE Guaranteed SoakENABLE/DISABLE Manual Hold CDR Cable connectionsComputer RS232 Format 550 socket Pin D type Support software Control Loops Appendix 1 Technical SpecificationOperating temperature Operator interface data entryData Logging AlarmsProgram Run Options Monitoring displaysTemp Hum LS Rep Digital Channels Ddhhmmss C Appendix 2 Program Looping and Nested LoopsLoop Instructions ExampleEvent statement time = event actual time total looping time Calculation for Succeeding EventsEffects on the Running Timebase Display Nested LoopsSeconds Example of Nested Loops Format Programming Sheet Appendix 3 Format 550 Programming SheetsLEU ORE Contact Information