Jacuzzi HE96000 manual Subfloor, English Electrical Connections, Pump/Motor with Heater

Page 9

Comfort PLUS Whirlpool Bath

Subfloor

Prepare the subfloor for the drain and ensure that the area is level.

1The drain/overflow of the bathtub extends below the bottom of the bathtub. Identify the drawing in the Technical Specifications Manual that corresponds with your bathtub.

2Make appropriate cuts to the subfloor to accommodate the drain.

3Jacuzzi’s Tru-Level™ base is a standard feature on all bathtubs. If the subfloor is level and a continuous surface, no other preparation is necessary. Proceed to the “Installation” section.

4If the subfloor is not level, you must level the entire surface prior to installing the bathtub. The materials used will insure that the bathtub is supported from the bottom. These materials include: leveling compound, mortar, plaster or minimal expansion structural foam (having a density of a minimum 5lbs/cubic foot). The bathtub must remain level in order for it to drain properly and must make contact with the leveling material. Both sides of a joint or splice of subfloor should be level to each other.

English

Electrical Connections

Risk of electric shock. Connect only to a circuit protected by a GFCI.

When using electrical products, basic precautions should always be followed:

Always follow local building and electrical codes.

Grounding is required. The unit should be installed and grounded by a qualified electrician.

Two separate GFCI protected circuits are required.

A separate, 120VAC, 15 AMP GFCI circuit is required for the pump/motor.

A separate 120VAC, 15AMP, GFCI protected circuit is required for the heater.

Risk of component overheat. Do not use electric extension cord to power this unit.

Operating the motor/pump without enough water in the bathtub can cause permanent damage to the pump.

Pump/Motor with Heater

Electrical outlets must be mounted 4˝ (101mm) above the floor line, or in accordance with local building and electrical codes.

-The pump/motor and heater require a dedicated 120VAC, 15 Amp GFCI protected circuit for each. The electrical outlets are not provided.

-Power cord from the pump/motor is routed to a control box t the factory. A supplied power cord from the control box with a 120VAC, 15 AMP plug connects to the customer-supplied GFCI protected circuit.

-Bonding lugs are provided on the motor to satisfy local electrical codes.

-At initial start-up, test GFCI units for proper operation. Follow the manufacturer’s direction for testing and proper use.

(101mm)

Figure 2

If the GFCI units indicate a malfunction, per manufacturer’s instructions, turn OFF power and do not use the bathtub until the source of the problem has been identified and corrected.

Installation and Operation

www.jacuzzi.com

Page 9

Image 9
Contents Comfort Plus Whirlpool Bath Series English English Product Information ContentsRead and Follow ALL INSTRUCTIONS. Save These Instructions Safety InstructionsSafety Instructions Operational Safety Instructions Operational Safety Instructions Inspection and Testing Visual Inspection Bathtub Water and Operational TestFraming and Support Subfloor English Electrical ConnectionsPump/Motor with Heater Canadian Models only English Reference IllustrationsDrop-in Installation Wall Alcove Installation Drop-in Installation con’tSkirt Installation Bathtubs with an Integral Skirt Undermount InstallationBathtubs with Optional Skirt General Operation Information CleanupWhirlpool Operation Chromatherapy Light OperationEnglish Air Flow if equipped Controlling Whirlpool Direction and FlowPurging the Whirlpool System Vacuum Switch MaintenanceHigh-Limit Switch Bathtub AdditivesTroubleshooting Procedures Suction Cover/Strainer MaintenanceSpecifications Rectangular Technical Specifications Rectangular Baths EnglishRiva 5.5 Plus Oval BathsTaraplus Left Hand Motor Corner Baths English11-1/8 Roughing-In Reference RectangularSigna 5 Plus LUNAPLUS, Left Hand Roughing-In Reference OvalCutout Roughing-In Reference Corner EnglishTara Plus Right-hand Back Motor Roughing-In Reference CornerSPECIFICATION/SERIAL Number Label Authorized ServiceLifetime Warranty on Baths Responsibilities of Others