Kenwood TS-440S manual PGS-1, PG.S-1, Memorychannellockout

Page 17

In example 1 we want to scan only Group 2, so we would press the 2 key. In example 2 we want to scan Group 1 and Group 2, so we would press the 1 key

and then the 2 key.

Example

1

Example 2

 

 

Group 2

GH1U-

Group 1

Group 2 .

~

~~

 

L;H1II--CH3U.--

lJM""

I.;M"\1

 

-oJ

 

-"'

t

4. You can stop scanning, or resume scan using the

same methods described above for the entire

memory scan.

3-7-2. Program scan

Two programmable scan ranges are provided on the TS-440S transceiver. PG .S-1 (Program Scan range 1) utilizes memory channels 06 and 07 to specify the up- per and lower scan limits. PG .S-2 (Program Scan range

2)utilizes memory channels 08 and 09 to specify the upper and lower scan limits.

To initiate PG.S

1.Press the VFO/M key to select VFO operation.

Press and hold the SCAN key

3.To initiate PG.S 1 press the 6 key, and then release both the 6 and the SCAN keys. Scan will begin on

the frequency programmed in memory channel number 6 and proceed in 10Hz steps to the upper limit stored in memory channel 7, then return to channel 6 and begin again.

,-PGS-1---,

CH6CH7

1401000 14.100.00

CWI'~I

.;

L,

4.To initiate PG.S 2 press the 8 key, and then release both the 8 and the SCAN key. Scan will proceed in the limits specified in memory channels 8 and 9, just as for PG.S 1.

,--Pu.S-2 ---,

CH8CH9

14.200.00 14.320.00

use. .~

5.If you want to scan both ranges PG.S 1 and PG.S 2, press the 6and then the 8 key while holding the SCAN key down, and then release the SCAN key. Scan will proceed thru the limits in memory chan- nels 6 and 7, thru the limits in memory channels 8 and 9, and then return to begin the process again.

,-PG.S-1--,

r- P(:i.~-;!-.

CH6

CH7

CH8

CH9

CW +

-1--.

u~~

 

l

 

 

 

 

 

6.To stop scanning press the Pi] switch, or the CLEAR key. Pressing the SCAN key allows scan to resume from the point you stopped.

.2418

Note: -~

,'j

The TS-440S microprocessor remembers the variou~ scan parameters that you have specified and will fol-

low whatever you have entered the next time you press the SCAN key.

Example 1: Memory mode

Previously programmed memory scan data was to scan channels 20-29 and

40-49.

To scan this same range again simply press the SCAN key.

Example 2: VFO mode

Previously entered program scan data was to scan both PG.S1 and PG.S2.

To initiate program scan over these two ranges again simply press the SCAN key.

The TS-440S will continue to execute scan according to the above parameters until you manually change the

information. This saves a lot of key strokes if you al- ways scan the same ranges, etc.

3-7-3. Scan speed

Two scan speeds are available with the T5-4405.

To change the speed press the 5CAN key after you have initiated scan. You will be able to toggle between fast and slow each time you press the key.

Note:

The scan step size depends upon the mode that has been selected for S5B, CW and AF5K the step size is 10Hz, for FM and AM the step size is 100 Hz.

3-7-4. Memorychannellockout

This transceiver has a memory channel lockout func- tion which allows you to temporarily skip unwanted memory channels during memory scan.

1.Press the VFO/M key to enter the memory mode.

2.Select the memory channel that you want to skip using the numeric keypad, the TUNING knob, or the UP/DOWN microphone or BAND switches.

3.Press the CLEAR switch.

A decimal point will appear in the M.CH display to indicate that the channel will be skipped.

,-,,:-n,

,_,. u

5.To cancel the lockout, select the desired channel and then press the CLEAR switch. The decimal point will go out indicating that the channel will again be scanned.

Image 17
Contents HF TRANSCEIVERTS-440S Kenwood Corporation Contents Wide dynamic range Switchable if bandwidthBuild-in XIT 0- 6.19-7/~oFixed Station Precaution~~~~~~~.~~ S-44~S To AC outlet To antennaJustment MobileAntenna II CJ,.-,, Lt.U @ RIT/XIT control@ RF gain control @ AF gain control@ Notch switch @ AGC switch@ F.LOCK switch @ 1 MHz step switch@ ATT Attenuator switch @ Standby switchNB Noise Blanker switch @ Voice switchANT ~=\~~GND @ ACC 2 jackGND PIN==---= ReceiveCW zero-beat operation QuencyTransmit ~udio signal~1ir FM mode CW modeBand TainedCussed below Dual Digital VFOsChanged ~i, CH ,j MemoryOFF ScanTwo methods may be used to clear a memory AgainMemorychannellockout PGS-1PG.S-1 Mode AfskOperation with a Linear AMPLI- Fier CrowdedReceiver Section Transmitter SectionCircuit Board Description General DescriptionCleaning ServiceGeneral Information Case of Difficul TVMicroprocessor Reset Microprocessor BACK-UP Lithium BatteryOrdering Spare Parts ModeBottom view Adjustments066 COt,~ Rear panel Guaranteed attenuation More than 80 dB Crystal Filter InstallationCenter frequency Passband widthSse Voice Synthesizer Unit VS-1 InstallationVS-1 UP/DOWN Interface IC KIT IC-10 InstallationMode RIT/XITMC-60A PS-50 MC-85MC-55 PS-430 MC-80MC-42S Other AccessoriesMeters bands 430 SP-50 TL-922A/TL-922 MB-430HS-6HS-5 ~32Earpads are provided Specifications T91-0352-05 AccessoriesCopy Dynamic microphone Except Europe and U.KAntenna Antenna installationMust Contact MOBll Operation InstallationTerference Noise reduction Radio Frequency Allocation Radio Frequency AllOCATIONBands