System Capacity
The UNIVERGE SV8100 can be configured for one of three capacities, 64‐port, 256‐port, or the unlimited 712‐ port system.
The table below highlights the system capacity of the SV8100 depending how many chassis are installed:
|
| 1 Chassis | 2 Chassis |
| 3 Chassis | 4 Chassis | SYSTEM |
|
|
| MAX. | ||||
|
|
|
|
|
|
| |
| Universal Slots | 6* | 12* |
| 18* | 24* |
|
| Time Slots | 111 | 222 |
| 333 | 444 |
|
| TDM Ports | 96 | 192 |
| 288 | 384 | 512 |
| MLT/DLC | 80 | 160 |
| 240 | 320 |
|
| SLT/LC (‐24V) | 80 | 176 |
| 272 | 368 |
|
| OPX/DIOP (‐48V) | 24 | 48 |
| 72 | 96 | 512 |
| IP MLT Extensions |
|
| 512 |
|
| |
| SIP Extensions |
|
| 512 |
|
| |
| Analogue Trunks | 40 | 88 |
| 136 | 184 |
|
| BRI ISDN Trunks | 40 | 88 |
| 136 | 184 | 200 |
| PRI ISDN Trunks | 90 | 200 |
| 200 | 200 | |
|
|
| |||||
| IP Trunks (SIP) |
|
| 128 |
|
| |
| VoIP Channels |
|
| 128 |
|
| |
| VM/VRS Channels |
|
| 16 |
|
| |
| V34 Modem |
|
| 1 |
|
| |
Comparison with previous systems: |
|
|
|
|
|
|
| IPK | IPK | IPK II | IPK II | SV8100 | SV8100 |
| SV8100 | |
| Basic | Expanded | Basic | Expanded | Basic | Expanded | Unlimited | ||
Max. Port Capacity | 48 | 184 | 64 | 456 | 64 | 256 | 712 |
| |
Universal slots | 24 | 24 | 24 | 24 | 24* | 24* | 24* |
| |
Outside Lines | 16 | 64 |
| 200 |
|
| 200 |
| |
IP Handsets |
|
|
|
|
|
|
|
|
|
Digital Handsets |
|
| 64 max | 256 max | 64 max | 256 max |
| 512 max |
|
Analogue Handsets | 32 max | 120 max |
|
|
|
|
| ||
|
|
|
|
|
|
| |||
Wireless Handsets |
|
|
|
|
|
|
|
|
|
CAR / VE |
|
| 256 max | 256 max | 256 max | 256 max |
| 256 max | |
DSS Modules | 4 max | 4 max | 32 max | 32 max | 32 max | 32 max |
| 32 max | |
Power Fail circuits | 3 | 3 | 3 | 3 | 44 | 44 | 44 |
| |
In‐Mail Ports | N/A | N/A | 4 | 4 | 16 | 16 | 16 |
|
Notes:
•The CD‐CP00‐AU (CPU) consumes one Universal Slot in the first chassis
•Without a PZ‐ME50 installed supports one chassis only with a maximum of 64 ports.
•Expanded or Unlimited requires the PZ‐ME50 and appropriate licensing.
•PFT requires use of the 4COT blade and provides 2 connections per blade.
Document No. SIB 244 | Page 4 of 52 | 1st July 2008 |
NEC Australia Pty Ltd shall not be liable for any direct, indirect, consequential or incidental damages about the use of the information included in this document. The information in this technical documentation is advisory in nature and is subject to change. NEC may make improvements and changes in the products described in this documentation without notice. Contents of this document are subject to change without prior notice at the discretion of NEC Australia Pty Ltd. This document has been prepared for use by employees and dealers of NEC Australia Pty Ltd and may not be reproduced without prior written approval of NEC Australia Pty Ltd.