Agilent Technologies 5071A manual Fuse

Page 17

Operating and Programming

Getting Started

9

48 VDC Input

POWER/FUSE 100VA MAX

 

 

 

Line:

1

00/120

V

 

 

220/240

V

Fuse: 2.5A

250V

Fuse:

1.5

AT

 

 

 

0.8

 

AT

 

 

 

 

 

 

 

 

Freq:

5

0-400

Hz

 

5

0-60

Hz

FUSE

 

CAUTION:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For continued protection against fire, replace

 

 

 

 

only with

fuse

of s ame

type

and

ratings.

!

 

 

Operating Voltage Range:

40 to 5 8 VDC

 

 

 

 

Input 1

GND

 

 

Input 2

 

 

 

 

48 VDC

 

 

48 VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120 Vac

TELECOM

48Volt

1.544 Mb/s

2.048 Mb/s

 

OPTIONS:

048

104

220

221

222

 

 

105

270

271

272

7

1-5

Image 17
Contents 7HOHFRPPXQLFDWLRQV2SWLRQV Page Telecommunications Options Supplemental Manual Before Cleaning Manual Updating Changes 05071-90042, December Contents Service Available Accessories and Options Supplemental CharacteristicsContents Instrument Identification How to Use This ManualManual Organization How to Order ManualsInstruments Covered by This manual Operating and Programming Introduction 5071A Major Features Introducing the 5071A Operating The 5071AGetting Started Connectors5071A at a Glance Rear-Panel Connections5071A Rear Panel Connections Fuse Starting The 5071A Powering Down the 5071APerforming Basic Tasks Synchronizing to an External 1 PPS ReferenceMonitoring Status Using the 5071ADisabling the Internal -Standby Battery Rear-Panel Output Connectors Front-Panel Indicators and MessagesCase of Difficulty Restarting the 5071A5071A Command Summary 5071A Command ReferencesScpi Subsystem Commands Scpi CommandsSpecifications Power Requirements InstallationOperating the 5071A From External Dc Power Preparation for UseReplacing the External Dc Input Power Fuse Internal Standby Battery MaintenanceLong-Term Storage Preparing the RP 5071-A For External-Dc OperationAssembly-Level Service 5071A Operational Verification Rear-Panel Output Signal ChecksPerformance Tests Option ServiceAssembly Identification and Location First Power On Top-Level Diagnostic Tree OrganizationTop-Level Diagnostic Tree Diagnostic Section Warm-up and Fatal Error Diagnostic Tree Advisory Messages Subsection Power-Supply Diagnostic Tree4.0.0 Ext. Dc Input Fuse Fault Ac-Line Fuse Fault Isolation r/o LF1/T1No Operation From Internal Standby Battery Internal-Battery Charger TestA8 Diagnostic Tree A/M Subsection 3 1 PPS Outputs Test Assembly/Module Diagnostic Trees Diagnostic Section4 A8 Front/Rear-Panel Sync Input Test 5 A8-to-Chassis Interconnect Test4.1 A9-to-Chassis TCO Option signal Interconnect Test A9 Diagnostic Tree A/M Subsection 5.0 A9 Mon Signal Test6.0 A9 J4 80-MHz Signal Test Introduction Theory of OperationSimplified Functional Description A1 Motherboard Circuit DescriptionInput/Output Block Power Supply BlockFunctional Block Descriptions Instrument Control Block Operating Firmware Warning ModeReference Oscillator/RF-Chain Block Interconnections Power Supply Block External Dc Input Circuit A1 Motherboard Circuit DescriptionOvervoltage Protection Circuit A1 Power Supply/Distribution Schematic Diagram A11 Power Steering Logic AssemblyInput Chassis Ground 48V Subpanel AssemblyA1 Power-Supply Block Diagram B1 Internal-Standby BatteryExchange Assemblies Replaceable PartsReplaceable Parts Backdating Backdating Specifications Internal Standby Battery Nominal Values Supplemental CharacteristicsTime Standard EnvironmentalAccessories Furnished Dc input connector WeightOptions Available Accessories and OptionsService and Support From front matter Declaration of Conformity Page Page Manual Part Number