Local Administrative Options
The displays on the 4612 and 4624 IP Telephones accommodate up to 24 characters per line. The display on the 4606 telephone accommodates up to 16 characters per line. Here and in the examples below, the example on the left shows the display on the 4612 and 4624 telephones, and the example on the right shows the display on the 4606 telephone.
Use the following procedure to invoke manual address information programming.
1.Start manual address programming by performing one of the following steps:
a.During normal DHCP processing, press the * key before the DHCP process completes. or
b.While the phone is
Hold 2 3 3 7 # (Hold A D D R #)
Press the Hold key momentarily. Do not press this key while pressing other keys.
The following message is displayed:
Phone=nnn.nnn.nnn.nnn |
|
New=_ | or |
nnn.nnn.nnn.nnn Phone=_
where “nnn.nnn.nnn.nnn” is the value of the telephone.
2. Enter the IP address for the telephone followed by the # button.
The following message is displayed:
CallSv=nnn.nnn.nnn.nnn |
|
New=_ | or |
nnn.nnn.nnn.nnn CallSv=_
where “nnn.nnn.nnn.nnn” is the value of the call server/gatekeeper IP address.
3.Enter the IP address for the gatekeeper followed by the # button. The following message is displayed:
CallSvPort=nnnnn
New=_
where “nnnnn” is the value of the Management Complex (call server/gatekeeper) transport- layer port number, a value between 0 and 65535.
Static Addressing Installation