automatic. The unit will continuously adapt to changing line conditions, making operation insensitive to line impedance changes.

In the Automated Operations mode, the RTU-292 combines the unique features of its adaptive DSP hybrid with fully unmanned auto-dial/auto-answer capability. In its standard configuration, the unit uses tone prompts to signal the remote user of the operations that must be performed to control the unmanned radio station. The addition of a Voice Prompt Option supplies a large number of spoken prompts to simplify control. The Local Phone Option allows a standard telephone set to be plugged into the rear panel of the RTU-292; this local phone may then be used in place of the unit's keypad and handset.

Input and output levels are internally adjustable to accommodate all types of radio systems. A set-up mode allows the adjustment of the RTU-292 receiver and transmitter signal levels without any external test equipment.

The unit will interface all types of two-wire lines, such as normal dial-up lines, dedicated lines, or twisted-pair field wire. Although the output impedance is fixed at 600 Ohms, the adaptive hybrid in the unit will give excellent hybrid balance regardless of the impedance of the line connected to the unit.

The unit operates from 115 or 230 VAC, 47 to 63 Hz, or from +12 or +24/+28 VDC nominal; the +12VDC range extends from +11 to +15 VDC, while the +24/+28 VDC range extends from +22 to +30 VDC. It is packaged in a rugged enclosure measuring 3.5"H x 19"W x 12"D. All inputs and outputs, including those for power, are filtered or protected as appropriate to enable the RTU-292 to meet the requirements of FCC Part 15 rules for a Class A Digital Device.

1.3 ASSEMBLIES

The standard RTU-292 contains five PC board assemblies; the main board (with plug-on adaptive hybrid DSP board), three front panel switch PC board assemblies, and the Options Interface Board, which is mounted in the Options Tray where other option boards may be installed. Mounted on the front panel along with the switchboards are a speaker, control potentiometers, phone jack and handset jack. The various I/O connectors and the DC power input connector are accessible via the rear panel.

1.3.1 MAIN BOARD

The main board has six general sections of circuitry: the Telephone Interface section, Handset/Speaker Interface section, Radio Interface section, DSP section, CPU section, and Power Supply section. These are described briefly in the following paragraphs. Refer to the RTU-292 block diagram along with the text. (The power supply and DSP sections are not shown in the block diagram, refer to Section 4 for more details.)

1.3.1.1 Telephone Interface

The Telephone Interface Section has the amplifiers that drive and receive audio from the phone line. This section also contains the DSP hybrid (which is detailed in Section 4 of this manual), interfaced with the keypad. A tone ringer generates a warble audio tone when ring voltage is received.

JPS Communications, Inc.

1-2

Image 12
Contents JPS Communications, Inc JPS P/N Revision JulyProprietary Statement Phone 919 Fax 919Table of Contents RTU-292 Theory of Operation Front Panel Buttons and Indicators Schematic Diagrams List Of Figures List of Tables Glossary This page intentionally left blank Scope Description GeneralAssemblies Main BoardTelephone Interface Power Supply Section Handset/Speaker InterfaceRadio Interface DSP ModuleEquipment and Accessories Supplied Qty Part NumberOptions Optional Equipment Not SuppliedRTU-292 Specifications General Unpacking and InspectionReshipment of Equipment Installation Overview Installation ConsiderationsFCC Part 68 Regulations 1RTU-292 Factory Default Settings Feature / Function Adjustment Default SettingPower Requirements Input Power SelectionDC Input Power Selection Line Voltage SelectionConfiguring the RTU-292 Programming Mode Setup ParametersSetting Telephone Send and Receive Levels Recommended Phone Line Settings Factory default settings are indicated by an asteriskType of System Telephone Send/Receive LevelsVOX Hangtime VOX HangtimeVOX Sensitivity VOX SensitivityDial Mode Dial ModeTelephone Ring Volume RX Line Input ImpedanceRadio Control Mode SW1-3 Radio Control Off Disabled EnabledFull/Half Duplex SW2-8 Full/Half Duplex Off Full DuplexPassword Protection 10Password Protection11Voice Prompts Enable Voice Prompts12Local Phone Enable 14TX Level Set-up ModeInterconnect Information 13 Local Phone RingthroughTelephone Connection 15J1 TEL Line RJ-11CPin Function Radio ConnectionHandset Connector 16P1-RADIO DB-9 Male17J7 Handset RJ12C Jack Terminal Block 18Terminal Block 6 PositionAudio Level Setup and Adjustments 19P2 RS-232 Connector DB-9 MaleSetting the Transmit Level 5 RS-232 ConnectionSetting the Receive Level 10.1.2RTU-292 Operations Manual Outline Dimensions Control and Connector Locations Location Of Internal Option Settings Internal Option Setting Details Audio Interface Wiring Diagram Interface Details Installation Checklist Options Installation and ConfigurationInstallation Checklist Front Panel CONTROLS, Indicators and Connectors Speaker Volume Control Phones Volume ControlKeypad TEL Line ButtonsSpeaker Buttons Auto ANS ButtonAudible Ring Button KEY PushbuttonRear Panel Connectors 1 P1 Radio Connector4 J2 Local Phone Connector 7 P1 AC Power ConnectorOperation Operation OverviewUSE of the RTU-292 Speaker to Monitor Audio Placing a Telephone CallUsing the Handset with the Radio Connecting the Radio to the Telephone LineReceiving a Telephone Call Putting a Telephone Call on HoldManual Phone Patch Procedure 8.18.2 8.3 8.48.5 8.6Negative Acknowledge Error Remote KEYSelf Test Automated OperationDisconnecting Disconnect Waiting For Input QueryRadio Is Keyed Keyed Radio Is Unkeyed UnkeyedCaller Enters The Password if enabled Caller Dials The RTU-292RTU-292 Adapts To The Phone Line RTU-292 Enters the Command Mode Placing a Call in the Command ModeTerminating a Call Dtmf Control Commands Operating the RTU-292 from the Front Panel Keypad1Standard Dtmf Operational Commands Dtmf Command Function2Programming Mode Dtmf Commands RTU-292 Password Protection Inactivity Disconnect TimerCalling Timer Using the RTU-292 Speed Dial Feature Using the Speed Dial FeatureProgramming the Speed Dial Directory Factory Reset Speed Dial ResetOptional 4 Wire Operation Front Panel Buttons and Indicators Main BoardAudio BUS Arrangement Telephone Interface Circuits Telephone Send CircuitsTelephone Receive Circuits Ring Detector and Tone Ringer Radio Interface CircuitsReceiver Input Amplifier Transmitter Audio OutputDtmf Detector FSK ModemMicrophone Circuit Speaker and Headphone CircuitsAudio Delay Adaptive HybridNoise Generator Peak DetectorPower Supply AC Power SupplyDC Power Supply 8 CPUOption Interface Board Voice Prompt OptionPrompt Tone Generator Speech ProcessorLocal Phone Option Voice Prompt SoftwareInterface Circuitry DIAL/BUSY GeneratorsRS-232 Remote Control Overview Commands Sent to the RTU-2921Command Summary Null Command Auto Answer CommandAudible Ring Command Date Command Dial CommandDisconnect Command Dtmf CommandHandset Phone Command Handset Radio CommandSpeaker Phone Command Speaker Radio CommandSpeed Dial Command SD nnALL num.? CRTel-Line Phone Command Tel-Line Radio CommandTime Command Software Version CommandStatus Returned from the RTU-292 Response SummaryNull Response Auto Answer ResponseCall Starting Response Dial Response Disconnect ResponseDtmf Response Elapsed Time Response Handset Phone ResponseHandset Radio Response Speaker Phone Response Speaker Radio ResponseSpeed Dial Response Tel-Line Phone ResponseTel-Line Radio Response Time/Date Response Version ResponseResponse Error Codes Response Error CodesCall Progress Responses from the RTU-292 Call Progress ResponsesPreventive Maintenance Repair or ReplacementPerformance Testing AlignmentHybrid Balance Measurement Hybrid Balance Test Set-Up Main Hybrid Test Procedure Alternate Hybrid Test Procedure VOX Sensitivity Test Set-Up VOX Test Procedure VOX Sensitivity MeasurementFault Analysis Replaceable Parts List DescriptionDescription Reference Designator RTU-292 Operations Manual Reference Designator Special Software Versions RTU-292 OptionsInstallation and Configuration Voice Prompts EnableSW1-6 Voice Prompts Off Disabled Enabled OperationVoice Prompt Option Installation Local Phone Option Installation and Configuration Local Phone EnableSW1-7 Local Phone Off Disabled Enabled SW1-8 Ringthrough Off Disabled Enabled5Local Phone Dtmf Commands Local Phone Option OperationVMM-100 Hardware VMM-100 DSP SectionVMM-100 Analog Interface VMM-100 Installation and Configuration VMM-100 SoftwareVMR Algorithm Noise Reduction AlgorithmVMM-100 Option Installation VMM-100 Specifications EnvironmentalVMM-100 I/O Connector Information P9 VMM-100 Switch FunctionsDtmf Access Option After the Call Begins Squelch Break Access Option RTU-292 Prompts for ConfirmationSetting The Time Setting The DateCall Logging Option Checking The Time And DateRadio Control Option Controlling the Radio VIA the RTU-292 Front Panel Keypad9DTMF Radio Control Commands Command Followed By Command DescriptionSchematic Diagrams Blank Index Environmental Self Test Speech Processor