4.3.2 TELEPHONE INTERFACE CIRCUITS

4.3.2.1 Telephone Send Circuits

Amplifier U1B generates the Telephone Send signal (the audio which is sent down the phone line from the RTU-292). U1B is configured as an inverting stage with its gain set by a combination of input and feedback resistors selected by analog gates U4A through U4D. The send level calibration assumes that there is a 0 dBm signal level at the input to U1B on U8B-

15.(If the setup is done properly, this is assured by the PEAK LED, which is set to flash at a peak level equivalent to 0 dBm.) The calibration is such that when a 600 Ohm load is placed on the telephone line terminals, the signal level at TP3 will be 3 dB lower than stated send signal level. This 3 dB margin allows some headroom for peaks in the program material without overdriving the phone line.

Resistor R1 establishes the output impedance of the telephone send amplifier, and (in parallel with R11) determines also the terminating impedance for the phone line.

Zener diodes CR2 and CR3 protect the circuitry in the RTU-292 from high voltage spikes on the phone line. 1:1 Audio transformer T1 couples the RTU-292 to the phone line. Capacitor C1 compensates the leakage inductance of the transformer to produce a flat frequency response. Capacitor C2 keeps the phone line DC current out of T1. Instead of using the secondary of T1 to sink the phone line DC holding current, an active constant current load is used which consists of CR1, Q1 and Q2 and associated components.

The constant current load provides a means of sinking the DC holding current from the phone line so that the RTU-292 will seize and hold the line. Bridge CR1 corrects the DC polarity so that a positive voltage is always applied to the collector of Q1, eliminating the need to be concerned about the polarity of the phone line. Transistors Q1 and Q2 are connected as a constant current load and C3 insures that the load does not respond to audio frequencies, so that the load appears as a very high AC impedance in parallel with the transformer secondary. When the load is in operation, the DC voltage from TP1 to TP2 will be approximately 4V to 8V.

The phone line connections are made via J1 or the terminal block J12 to relay K1, which, when the power is off or the unit is in Disconnect, disconnects the phone line from the internal circuitry. Components L1, L2 and associated capacitors form Pi-Section filters to remove RF from the normally unshielded phone lines. RV1 is a metal-oxide varistor that limits high voltage transients that might appear on the telephone line.

4.3.2.2 Telephone Receive Circuits

Amplifier U2A is the telephone receive amplifier, which is arranged as a non inverting stage and gets its input via R11 from transformer T1. U2B is gain adjustable via a combination of input and feedback resistors selected by analog gates U6A - U6D. The gain distribution is set so that, with a 600 Ohm load on the telephone line terminals, the PSTN level stated in the Input Signal Level Table will produce a -12 dBm signal at U2B-7.

Note that the telephone send signal appears mixed with the telephone receive signal at U2A-1. Furthermore, the amount of send signal mixed in depends on the telephone line impedance, and is also frequency dependent. It is the job of the DSP hybrid to remove the telephone send signal and pass only the telephone receive signal to the transmitter output circuits. The inputs to the adaptive hybrid are A/D 2 (U1A-1) and A/D 1 (U2B-7). The DSP hybrid essentially subtracts

JPS Communications, Inc.

4-20

Image 60
Contents JPS Communications, Inc JPS P/N Revision JulyProprietary Statement Phone 919 Fax 919Table of Contents RTU-292 Theory of Operation Front Panel Buttons and Indicators Schematic Diagrams List Of Figures List of Tables Glossary This page intentionally left blank Scope Description GeneralAssemblies Main BoardTelephone Interface Power Supply Section Handset/Speaker InterfaceRadio Interface DSP ModuleEquipment and Accessories Supplied Qty Part NumberOptions Optional Equipment Not SuppliedRTU-292 Specifications General Unpacking and InspectionReshipment of Equipment Installation Overview Installation ConsiderationsFCC Part 68 Regulations 1RTU-292 Factory Default Settings Feature / Function Adjustment Default SettingPower Requirements Input Power SelectionDC Input Power Selection Line Voltage SelectionConfiguring the RTU-292 Programming Mode Setup ParametersSetting Telephone Send and Receive Levels Recommended Phone Line Settings Factory default settings are indicated by an asteriskType of System Telephone Send/Receive LevelsVOX Hangtime VOX HangtimeVOX Sensitivity VOX SensitivityDial Mode Dial ModeTelephone Ring Volume RX Line Input ImpedanceRadio Control Mode SW1-3 Radio Control Off Disabled EnabledFull/Half Duplex SW2-8 Full/Half Duplex Off Full DuplexPassword Protection 10Password Protection11Voice Prompts Enable Voice Prompts12Local Phone Enable 14TX Level Set-up ModeInterconnect Information 13 Local Phone RingthroughTelephone Connection 15J1 TEL Line RJ-11CPin Function Radio ConnectionHandset Connector 16P1-RADIO DB-9 Male17J7 Handset RJ12C Jack Terminal Block 18Terminal Block 6 PositionAudio Level Setup and Adjustments 19P2 RS-232 Connector DB-9 MaleSetting the Transmit Level 5 RS-232 ConnectionSetting the Receive Level 10.1.2RTU-292 Operations Manual Outline Dimensions Control and Connector Locations Location Of Internal Option Settings Internal Option Setting Details Audio Interface Wiring Diagram Interface Details Installation Checklist Options Installation and ConfigurationInstallation Checklist Front Panel CONTROLS, Indicators and Connectors Speaker Volume Control Phones Volume ControlKeypad TEL Line ButtonsSpeaker Buttons Auto ANS ButtonAudible Ring Button KEY PushbuttonRear Panel Connectors 1 P1 Radio Connector4 J2 Local Phone Connector 7 P1 AC Power ConnectorOperation Operation OverviewUSE of the RTU-292 Speaker to Monitor Audio Placing a Telephone CallUsing the Handset with the Radio Connecting the Radio to the Telephone LineReceiving a Telephone Call Putting a Telephone Call on HoldManual Phone Patch Procedure 8.18.2 8.3 8.48.5 8.6Negative Acknowledge Error Remote KEYSelf Test Automated OperationDisconnecting Disconnect Waiting For Input QueryRadio Is Keyed Keyed Radio Is Unkeyed UnkeyedCaller Enters The Password if enabled Caller Dials The RTU-292RTU-292 Adapts To The Phone Line RTU-292 Enters the Command Mode Placing a Call in the Command ModeTerminating a Call Dtmf Control Commands Operating the RTU-292 from the Front Panel Keypad1Standard Dtmf Operational Commands Dtmf Command Function2Programming Mode Dtmf Commands RTU-292 Password Protection Inactivity Disconnect TimerCalling Timer Using the RTU-292 Speed Dial Feature Using the Speed Dial FeatureProgramming the Speed Dial Directory Factory Reset Speed Dial ResetOptional 4 Wire Operation Front Panel Buttons and Indicators Main BoardAudio BUS Arrangement Telephone Interface Circuits Telephone Send CircuitsTelephone Receive Circuits Ring Detector and Tone Ringer Radio Interface CircuitsReceiver Input Amplifier Transmitter Audio OutputDtmf Detector FSK ModemMicrophone Circuit Speaker and Headphone CircuitsAudio Delay Adaptive HybridNoise Generator Peak DetectorPower Supply AC Power SupplyDC Power Supply 8 CPUOption Interface Board Voice Prompt OptionPrompt Tone Generator Speech ProcessorLocal Phone Option Voice Prompt SoftwareInterface Circuitry DIAL/BUSY GeneratorsRS-232 Remote Control Overview Commands Sent to the RTU-2921Command Summary Null Command Auto Answer CommandAudible Ring Command Date Command Dial CommandDisconnect Command Dtmf CommandHandset Phone Command Handset Radio CommandSpeaker Phone Command Speaker Radio CommandSpeed Dial Command SD nnALL num.? CRTel-Line Phone Command Tel-Line Radio CommandTime Command Software Version CommandStatus Returned from the RTU-292 Response SummaryNull Response Auto Answer ResponseCall Starting Response Dial Response Disconnect ResponseDtmf Response Elapsed Time Response Handset Phone ResponseHandset Radio Response Speaker Phone Response Speaker Radio ResponseSpeed Dial Response Tel-Line Phone ResponseTel-Line Radio Response Time/Date Response Version ResponseResponse Error Codes Response Error CodesCall Progress Responses from the RTU-292 Call Progress ResponsesPreventive Maintenance Repair or ReplacementPerformance Testing AlignmentHybrid Balance Measurement Hybrid Balance Test Set-Up Main Hybrid Test Procedure Alternate Hybrid Test Procedure VOX Sensitivity Test Set-Up VOX Test Procedure VOX Sensitivity MeasurementFault Analysis Replaceable Parts List DescriptionDescription Reference Designator RTU-292 Operations Manual Reference Designator Special Software Versions RTU-292 OptionsInstallation and Configuration Voice Prompts EnableSW1-6 Voice Prompts Off Disabled Enabled OperationVoice Prompt Option Installation Local Phone Option Installation and Configuration Local Phone EnableSW1-7 Local Phone Off Disabled Enabled SW1-8 Ringthrough Off Disabled Enabled5Local Phone Dtmf Commands Local Phone Option OperationVMM-100 Hardware VMM-100 DSP SectionVMM-100 Analog Interface VMM-100 Installation and Configuration VMM-100 SoftwareVMR Algorithm Noise Reduction AlgorithmVMM-100 Option Installation VMM-100 Specifications EnvironmentalVMM-100 I/O Connector Information P9 VMM-100 Switch FunctionsDtmf Access Option After the Call Begins Squelch Break Access Option RTU-292 Prompts for ConfirmationSetting The Time Setting The DateCall Logging Option Checking The Time And DateRadio Control Option Controlling the Radio VIA the RTU-292 Front Panel Keypad9DTMF Radio Control Commands Command Followed By Command DescriptionSchematic Diagrams Blank Index Environmental Self Test Speech Processor