6.5.2.2 Alternate Hybrid Test Procedure
This alternate test procedure uses a more easily obtainable audio signal generator in place of the noise generator. While this procedure cannot give a complete picture of the unit’s performance in actual use, it will allow a determination of whether or not the
1.Disconnect the
2.. Set the PSTN levels for
3.Start with the following pushbuttons OFF: TEL LINE/PHONE, TEL LINE/RADIO, and TEL VOX. The positions of the other buttons are unimportant. Place the
4.Adjust the TX Level Adjust, R133, so that the audio voltmeter reads
5.Set the output amplitude of the audio signal generator to about 0dBm (0.775V rms). Adjust the RX Level Adjust so that the PEAK LED just comes on. This will set the average noise level into the
6.Remove the unit from
7OFF, and then turning the main power back ON.
7.Set the audio generator frequency to about 1 kHz.
8.Push the TEL LINE/RADIO button to start the adaptation cycle.
9.When the initial adaptation cycle is complete, the tone output can be read on the audio voltmeter. The voltage should be typically less than
NOTE
The reading should be made as soon as the adaptation cycle is complete. The
10.To measure the unit at a different frequency, change the audio generator frequency and repeat steps 8 and 9.