Keating Of Chicago 2000 warranty Shutdown Instructions, OIL Breakdown, Draining

Page 8

CAUTION

OPERATION OF THIS FRYER SHOULD BE LIMITED TO PERSONNEL WHO HAVE BEEN THOROUGHLY TRAINED IN OPERATING PROCEDURES.

Set thermostat to the desired frying temperature.

CAUTION

CARE SHOULD BE TAKEN WHEN LOWERING BASKETS INTO FRYER TO PREVENT SPLASHING HOT OIL FROM FRYER VESSEL.

If your fryer has timers, push “Start-Stop” button of electronic timer(s). For fryers with automatic basket lift, basket(s) will lower into fryer vessel.

When timer(s) sounds, carefully lift basket(s) out of hot oil. For fryers with automatic basket lift, a buzzer will sound and the basket(s) will rise automatically. Allow oil to drain before removing.

CAUTION

DO NOT LIFT BASKETS DIRECTLY OUT OF THE FRYER VESSEL WITHOUT DRAINING AS SEVERE INJURY MAY RESULT

USE ONLY KEATING APPROVED BASKETS IN YOUR FRYER. NEVER OVERFILL FRY BASKETS. DO NOT BANG BASKETS ON BASKET HANGERS OR ON FRYER VESSEL.

Place basket(s) on basket hanger rods on splashback of fryer and allow to drain.

SHUTDOWN INSTRUCTIONS

Always turn the fryer off each night.

1. See Shutdown procedure.

OIL BREAKDOWN

As part of a “Preventive Maintenance Program”, the oil in your fryer needs to be filtered regularly. The initial investment in the frying system is less than the total overall costs of oil during the life of the fryer, and with regular filtering, you can realize substantial savings in oil costs, as well as, maintenance charges. We have listed some of the conditions which are catalysts in the breakdown of oil:

1.Contact with Oxygen

2.Carbonization of Crumbs and Food Particles

3.Non-Stainless Steel Surfaces

4.Keep Salt and Seasonings Away From Oil

5.Prolonged High Temperatures

DRAINING

Operator in safety gear

CAUTION

ALWAYS SHUT THE FRYER OFF COMPLETELY BEFORE DRAINING. THE FRYER SHOULD BE DRAINED ONLY UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL. A DRAIN PIPE AND COVERED CONTAINER SUITABLE FOR USE WITH HOT OIL SHOULD BE USED TO ENSURE THE SAFETY OF THE OPERATOR.

1.Operator should be outfitted with proper attire including:

–Oil and heat resistant gloves –Oil and heat resistant apron –Safety goggles

–Oil and heat resistant footwear

2.Turn off the fryer and open the door.

3.Put suitable container under drain valve.

4.Drain oil from fryer by slowly turning handle. The drain will be completely open after 1/4 turn.

5.After fryer drains close the drain valve.

6.Filtering may be done at this step.

NOTE: Fryers with a central filter will drain differently.

CLEANING AND BOIL-OUT FOR A

SINGLE FRYER

When cleaning and boiling out your fryer use Keating Sea Powder and Keating Klenzer to keep your fryer in top condition.

1.Operator should be outfitted with proper attire including:

–Oil and heat resistant gloves –Oil and heat resistant apron –Safety goggles

–Oil and heat resistant footwear

Turn the fryer off. Remove baskets and screen.

2. Drain oil from fryer, see draining.

6

Image 8 Contents
Contents InstallationOperator Self Help Check List Preventative Maintenance Warranty RepairsFor Your Safety Suitable for Combustible Floors Venti Lation If Equipment Arrives DamagedMinimum Clearance Installation Flexible GAS Connectors and Quick DIS Connect DevicesGAS Connections and Pipe Size Restraining DevicesLeveling FillingDo BI-MONTHLY AA Models Operating Instructions START-UP ProcedureBB Models Operating Instructions START-UP Procedure TS Models Operating Instructions START-UP Procedure High Limit Test Procedure do BI-MONTHLYShutdown Procedure CookingCleaning and BOIL-OUT for a Single Fryer Shutdown InstructionsOIL Breakdown DrainingSafe & Easy Filter Side View Do not MIX Water and HOT OILOccurrence Solution Operator Self HelpPreventive Maintenance Chart Time OPERATOR/OWNER Frame Qualified ServiceHI-LIMIT Check BI-MONTHLY Thermostat CalibrationKeating Electronic Timer HOW to Program the Keating Checking Continuity with the MultimeterControl Panel AA GAS Optional Timer Operating InstructionsOrdering Parts Control Panel BB GAS Control Panel TS GAS DescriptionQTY.DESCRIPTION QTY. DescriptionElectrical BOX Assembly GAS Fryer POT Assembly 14AA GASPOT Assembly 14BB & 14TS GAS POT Assembly 18AA GASPOT Assembly 18BB & 18TS GAS POT Assembly 20AA GASPOT Assembly 20BB & 20TS GAS POT Assembly 24BB & 24TS GASAA2000 Electrical Assembly BB2000 Electrical AssemblyTS2000 Electrical Assembly BB Electrical Assembly with SE FilterPage Problem Probable Cause Solution Page Service Information Keating Limited Warranty Card