Follow the steps below to set up the system. Throughout the instructions, the Voice Center Conference Phone is referred to as “Conference Phone” and the DT-104 Digital Telephone System Interface is referred to as “Digital Interface.”

1. Connect Conference Phone to Digital Interface using the RJ-45

conference phone cable supplied with the Conference Phone.

• Plug one end of the RJ-45 conference phone cable (larger than a standard RJ-22 cable) into the connector labeled “Control Box” on the underside of the Conference Phone.

• Plug the other end of the RJ-45 cable into the Digital Interface connector labeled “Conference Phone.”

PHONE

LINE

CONFERENCE

DC 15V

 

 

PHONE

 

2.Connect Digital Interface to digital telephone using RJ-22 telephone handset cables.

Unplug handset “curly cord” from digital telephone and plug it into the Digital Interface connector labeled “Handset.”

PHONE

LINE

CONFERENCE

DC 15V

 

 

PHONE

 

Plug one end of RJ-22 telephone handset cable supplied with the Digital Interface into the Digital Interface connector labeled “Phone.”

Plug the other end of that RJ-22 cable into the handset jack on the digital telephone (from which the handset curly cord was disconnected). See diagram at top of page 9.

Hang up the handset on the digital telephone.

3.Connect Conference Phone power adapter to Digital Interface. In North America, use 120 VAC power adapter (PA-102, supplied with Conference Phone); in Europe, use 230 VAC power adapter (PA-202, available in EK-102 international adapter kit).

Plug DC plug on power adapter cord into the Digital Interface con- nect labeled “DC15V.”

Plug power adapter into a nearby electrical outlet (do not exceed voltage rating of power adapter).

Note: At this point, the Conference Phone will emit a musical jingle; this self-test allows it to automatically calibrate its performance for the acoustic environment.

Note: See system illustration on next page.

PHONE

LINE

CONFERENCE

DC 15V

 

 

PHONE

 

PHONE

LINE

CONFERENCE

DC 15V

 

 

PHONE

 

8

Image 9
Contents Model CP-2012 Voice Center Conference PhoneTable of Contents Voice Center User’s Manual Safety Precautions Package ContentsQuick Start Guide IntroductionAnalog or Digital Telephone System? Setup TipsAnalog DigitalAnalog Telephone System Setup with Analog Telephone System Selection of Tone or Pulse Dialing Wall Mounting of Analog Interface OptionalON/OFF Keypad Functions with Analog Phone SystemThree-way calling Conference Phone Operation with Analog Phone SystemDigital Telephone System Setup of Conference Phone with Digital Phone SystemWall Mounting of Digital Interface Optional Digital SystemsStandard 12-button Telephone Keypad, REDIAL, Flash Keypad Functions with Digital Phone SystemConference Phone Operation with Digital Phone System General Setup Tips Setting up the Conference Phone Global RegionTips for Obtaining Optimal Acoustic Performance Eneral Conference Phone SpecificationsUSA Spracht Limited Warranty PolicyPage Federal Communications Commission Statement Tel Fax Bayshore Parkway, Bldg Mountain View, CA 94043 USA