Furuno ARP-17 manual Alarms, CPA/TCPA alarm

Page 15

OTHERS

12. Alarms

1.HDG SET

2.SPD MODE

3.MAN SPD

4.SET & DRIFT

5.DISPLAY

6.MARK/LINE

7.TUNE

8.NAV DATA

9.EBL/VRM/+

0.

MAN LOG NAV*

LOG (S-BT)

LOG (S-WT)

CPA/TCPA alarm

Visual and audible alarms are generated when the predicted CPA and TCPA of any target become less than their preset limits. Press the [AUDIO OFF] key to acknowledge and silence the CPA/TCPA audible alarm.

The ATA continuously monitors the predicted range at the Closest Point of Approach (CPA) and predicted time to CPA (TCPA) of each tracked target to own ship.

* NAV shown on R-type only.

Figure 9 OTHER menu

2.Press the [4] key twice to select SET/

DRIFT.

 

SET & DRIFT

1.

 

 

2.

SET/DRIFT

 

ON

OFF

3.

SET

000.0

4.

DRIFT

0-19.9 KT

Figure 10 SET/DRIFT menu

3.Press the [2] key to select ON from the SET DRIFT field, and then press the [EN- TER/SELECT] key.

4.Press the [3] key twice, enter SET value, and then press the [ENTER/SELECT] key.

5.Press the [4] key twice, enter DRIFT value, and then press the [ENTER/SE- LECT] key.

6.Press the [MENU] key.

When the predicted CPA of any target be- comes smaller than a preset CPA alarm range and its predicted TCPA less than a preset TCPA alarm limit, the ATA releases an au- dible alarm. In addition, the target plot sym- bol changes to a triangle and flashes together with its vector.

Provided that this feature is used correctly, it will help prevent the risk of collision by alert- ing you to threatening targets. It is important that GAIN, A/C SEA, A/C RAIN and other radar controls are properly adjusted and the ATA is set up so that it can track targets ef- fectively.

CPA/TCPA alarm ranges must be set up prop- erly taking into consideration the size, ton- nage, speed, turning performance and other characteristics of own ship.

The CPA/TCPA alarm feature should never be relied upon as a sole means for detecting the risk of collision. The navigator is not re- lieved of the responsibility to keep visual look- out for avoiding collisions, whether or not the radar or other plotting aid is in use.

Follow the steps shown below to set the CPA/ TCPA alarm ranges:

1.Press [MENU], [7], [7] to display PLOT MENU 1.

2.Press [5] (CPA SET) to select CPA limit desired from the CPA SET line.

3.Press the [ENTER/SELECT] key.

4.Press [6] (TCPA SET) to select a TCPA limit desired.

10

Image 15
Contents Automatic Tracking AID B . N o . O M E 3 0 4 6 Safety Instructions Table of Contents Features ForewordWord to Furuno ARP-17 Owners Acquisition and tracking Operational OverviewIntroduction Criteria of TrackingOther ship maneuvers Qualitative description of tracking errorAutomatic acquisition areas and suppression lines Own ship maneuversControls Controls, Menu DescriptionMenu description Menu treeActivating, Deactivating the ATA Entering Own Ship’s SpeedAutomatic speed input Manual acquisition Acquiring TargetsManual speed input Target-based speed input Automatic acquisition Changing plot symbol shapeTerminating Tracking of Targets VectorsDisplaying Target Data Selecting plotting interval Past Position DisplaySet and Drift Displaying dataCPA/TCPA alarm AlarmsTrack Test Simulation Display Silencing CPA/TCPA audible alarmLost target alarm Guard zone alarmCPA Tcpa Diagnostic SequenceOutputting Target Data Specifications of Auto Plotter Index